• Title/Summary/Keyword: 배기 통로

Search Result 68, Processing Time 0.03 seconds

A Study on the Standard for Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치기준에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the last five years, 36 people died and 79 were wounded because of carbon monoxide poisoning accident. A CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread mechanism of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. A CO gas leaked form exhaust tube in a building was the highest concentrated near the ceiling. CO alarm sets installation test confirmed that the alarm sets near the ceiling operated first, and the bottom and middle sets operated after $30{\sim}40$ minutes. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Screw Vacuum Pump의 Screw 리드의 변화에 따른 성능평가 연구

  • Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.153-153
    • /
    • 2014
  • 건식 진공펌프(dry vacuum pump)는 기계적 저진공펌프 중 펌프 내부의 기체 배기통로에 오일을 전혀 사용하지 않는 펌프의 통칭으로써, 대개 비접촉형으로 여러 형태의 회전자가 고속으로 회전하면서 흡기구로부터 들어온 기체를 압축해 배기를 한다. 비접촉형에는 루츠(roots)형, 클로(claw)형, 스크류(screw)형, 스크롤(scroll)형 등이 있다. 그 중 스크류형 펌프는 큰 배기속도를 갖는 펌프의 설계에 유리하고 높은 운용온도가 가능하여 다수공정에 쉽게 적용할 수 있는 장점이 있다. 그러나 1단 펌프 구성을 갖게 됨에 따라 루츠형 대비 높은 소비전력 특성을 보이는 약점을 가지고 있다. 본 논문에서는 건식 진공펌프 중의 하나인 스크류형 진공펌프에 대하여, 기본적인 1단 펌프 구성에 스크류 리드(lead)의 변화를 주어 기존의 똑같은 리드의 스크류 진공펌프에 대한 소비전력 및 배기구 온도 등 스크류 형상에 대한 성능평가 연구를 진행 하고자 한다.

  • PDF

A Study on the Flow Entrainment Characteristics of a Coaxial Nozzle Used in a MILD Combustor with the Change of Nozzle Position and Flow Condition (MILD 연소로에서 노즐의 위치와 유동 조건에 따른 유입량 특성에 관한 연구)

  • Shim, Sung-Hoon;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • A MILD (Moderate and Intense Low oxygen Dilution) combustor decreases NOx formation effectively during the combustion process and NOx formation is affected significantly by the exhaust gas entrainment rate toward fuel and air. The present study focused on the new MILD combustor, which has coaxial cylindrical tube. The outside tube of the new MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. The connection pipe is set between the outer side and the inner side tubes and coaxial air nozzle is inserted at the center of the connection pipe. A numerical analysis is accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of air nozzle exit velocity, nozzle diameter, nozzle exit position and exhaust gas side pressure. The entrainment rate is proportional to the square root of air nozzle exit velocity and negatively proportional to the pressure difference between the exhaust gas side and furnace side pressures. The effect of air nozzle exit position is not considerable on the exhaust gas entrainment.

An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle (MILD 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2013
  • The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of venturi nozzle geometrical parameters, nozzle position, nozzle gap between high pressure air nozzle and venturi nozzle, and with the change of high pressure nozzle inlet velocity. The entrainment flow rate for the case with the high pressure air nozzle attached at the exhaust gas wall has relatively small change with the change of nozzle gap. That for the case with the high pressure air nozzle exposed to the exhaust gas has monotonically increase with the change of nozzle gap. The flow rate ratio of entrainment flow rate has considerably increase tendency with relatively lower air inlet velocity, on the other hand, that with relatively higher air inlet velocity could be seen relatively small increase.

Influence of Compression Ratio on Engine Performance in Heavy-duty LPG Single-cylinder Engine (대형 LPG 단기통엔진에서 압축비가 기관성능에 미치는 영향)

  • 김진호;최경호
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.160-165
    • /
    • 2002
  • The heavy-duty LPG-fueled single cylinder engine was designed and developed as a fundamental equipment for analyzing combustion processes and emission performances. The cylinder head and the piston crown were modified to fire the LPG in the engine. The flywheel was also fabricated to minimize the vibration of the single cylinder engine. The size of bore and stroke of the tested engine are 130 mm and 140 mm, respectively. Compression ratios were varied 8 to 9 with different piston crown shapes. The developed single cylinder engine operates at 1,000 rpm for this work. The major conclusions of this work are; (1) the power of the developed engine was peaked at the condition of equivalence ratio 1.0 at three different compression ratios; (2) the power is slightly increased with the increase of compression ratio; (3) the optimum ignition timing is retarded with the increase of compression ratio ranged 2 to 10 crank angle.

Computational Approach to Improve Diesel Engine Coolant Flow Characteristics (디젤엔진 냉각수 유동특성 개선을 위한 수치해석적 접근방법)

  • Lee, Sung-Won;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1133-1136
    • /
    • 2010
  • 2600cc급 디젤엔진의 냉각수 유동특성 개선을 위한 수치해석적 방법을 제시하기 위하여 본 연구가 수행되었다. 실린더 블록 및 헤드의 유동특성 분석을 위하여 개스킷 냉각수 통로의 면적과 갯수가 중점적으로 고려되었다. 베이스 모델의 수치해석적 분석에서 입구측에 치우친 냉각수 홀의 배치에 의하여 1, 2번 실린더 헤드로만 주 유동이 발생되었다. 이러한 문제점을 개선하기 위하여 개스킷 냉각수 통로를 재설계하였다. 수정모델은 주 유동이 4번 실린더 측으로 유도되었으며, 배기밸브 사이의 유동도 개선되었다. 재설계과정에서 개스킷 냉각수통로의 전체면적을 고려치 않게 되면 유량이 줄어들게 되는 문제점이 발견되었다. 본 연구를 통하여 실린더 헤드와 블록사이의 냉각수 유동을 제어하는 개스킷의 중요성을 확인하였으며, 냉각수 유동특성 최적화는 개스킷 홀의 총 면적을 고려하여 냉각수의 총질량유량을 설계하여야 한다.

  • PDF

Combustion and Exhaust Emission Characteristics by the Change of Intake Air Temperature in a Single Cylinder Diesel Engine (단기통 디젤엔진에서 흡기온도변화에 따른 연소 및 배기특성)

  • Shin, Dalho;Park, Suhan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.336-343
    • /
    • 2017
  • Intake air conditions, such as air temperature, pressure, and humidity, are very important parameters that influence engine performance including combustion and emissions characteristics. The purpose of this study is to investigate the effects of intake air temperature on combustion and exhaust emissions characteristics in a single cylinder diesel engine. In this experiment, an air cooler and a heater were installed on the intake air line and a gas flow controller was installed to maintain the flow rate. It was found that intake air temperature induced the evaporation characteristics of the fuel, and it affects the maximum in-cylinder pressure, IMEP(indicated mean effective pressure), and fuel consumption. As the temperature of intake air decreases, the fuel evaporation characteristics deteriorate even as the fuel temperature has reached the auto-ignition temperature, so that ignition delay is prolonged and the maximum pressure of cylinder is also reduced. Based on the increase in intake air temperature, nitrogen oxides(NOx) increased. In addition, the carbon monoxide(CO) and unburned hydrocarbons(UHC) increased due to incomplete fuel combustion at low intake air temperatures.