• Title/Summary/Keyword: 배관 결함

Search Result 610, Processing Time 0.026 seconds

Growth Characteristics of Common Ice Plant (Mesembryanthemum crystallinum L.) on Nutrient Solution, Light Intensity and Planting Distance in Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 배양액, 광도 및 재식거리에 따른 Common Ice Plant의 생육 특성)

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • This study was conducted to determine the optimum nutrient solution, pH, irrigation interval, light intensity and planting density to growth of common ice plant (Mesembryanthemum crystallinum L.) in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-h photoperiod were used. Nutrient film technique systems with three layers were used for the plant growth system. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Treatments were comparison of the nutrient solution of Horticultural Experiment Station in Japan (NHES) and the nutrient solution of Jeju National University (NJNU), pH 6.0 and 7.0, irrigation interval 5 min and 10 min, light intensity 90 and $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and within-row spacing 10 cm, 15 cm, 20 cm and 25 cm with between-row spacing 15 cm. Optimum macronutrients were composed N 7.65, P 0.65, K 4.0, Ca 1.6 and Mg $1.0mM{\cdot}L^{-1}$. There were no significant interactions between pH 6.0 and 7.0 about shoot fresh weight and shoot dry weight of common ice plant. Irrigation interval 5 min and 10 min was also the same result. Shoot fresh weight and shoot dry weight were highest at $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Shoot fresh weight and shoot dry weight were decreased according to increasing the planting density. From the above results, we concluded that optimum nutrient solution, optimum levels of pH, irrigation interval, light intensity and planting density were 6.0-7.0 and 10 min, $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and $15{\times}15cm$, respectively for growth of common ice plant in a closed-type plant production system.

The 'Consequence Analysis' of Variables Affecting the Extent of Damage Caused by Butane Vapor Cloud Explosions (부탄가스 증기운폭발의 피해범위에 영향을 미치는 변수에 관한 고찰)

  • Char Soon-Chul;Choo Kwang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.1-7
    • /
    • 2001
  • This paper presents a 'consequence analysis' for vapor cloud explosions caused by heavy gas leakages from commercially used storage tanks at petrochemical plants. Particularly, this paper emphasizes on evaluating the results of various vapor cloud explosion accidents from Butane storage tanks. Also this paper analyses the impact of variables on the accidents in order to acquire the optimum conditions for variables. $SuperChems^{TM}$ Professional Edition was applied to analyse the impact (If atmospheric and other variables in the situation where vapor cloud continuously disperses from the ground level. Under the assumption that practical operating conditions are selected as a standard condition, and Butane leaks from the storage tank for 15 minutes, the results show that the maximum distance of LFL (Lower Flammable Limit) was 52 meters and overpressure by the vapor cloud explosion was 1 psi at 128.2 meters. It is observed that the impact of the variables on accidental Butane storage tank leakage mainly varied upon atmospheric stability, wind velocity, pipe line size, visible length, etc., and changes in the simulation result occurred as the variables varied. The maximum distance of the LFL (Lower Flammable Limit) increased as the visible length became shorter, the size of the leak became larger, the wind velocity was decreased, and the climatic conditions became more stable. Thus, by analysing the variables that influence the simulation results of explosions of Butane storage tanks containing heavy gases, I am presenting the most appropriate method for 'consequence analysis' and the selection of standards for suitable values of variables, to obtain the most optimal conditions for the best results.

  • PDF

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

The Flora of Habitats Distributed with Allium victorialis var. platyphyllum Populations in the South Korea (우리나라 산마늘 개체군 자생지의 식물상)

  • Kim, Hye-Jin;Doh, Eun-Soo;Chang, Jun-Pok;Choi, Myung-Suk;Yang, Jae-Kyung;Cho, Hyun-Je;Bae, Kwan-Ho;Shin, Hak-Sub;Park, Hee-Kwon;Lee, Seo-Hui;Yun, Chung-Weon
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.3
    • /
    • pp.284-294
    • /
    • 2011
  • This study was conducted to investigate the flora of habitats distributed with Allium victorialis var. platyphyllum populations in the South Korea. The vascular plants were surveyed 4 times from March 2009 to June 2010. The flora of studied area was listed as 214 taxa; 64 families, 142 genus, 181 species, 2 subspecies, 30 varieties, 1 forma. According to the specific plant species by classes, class I has 17 taxa; 15 families, 16 genus, 15 species, 2 varieties. Class II has 16 taxa; 13 families, 16 genus, 15 species, 2 varieties. Class III has 20 taxa; 16 families, 19 genus, 18 species, 2 varieties. Class III has 20 taxa; 16 families, 19 genus, 18 species, 2 varieties. Class IV has 23 taxa; 20 families, 23 genus, 19 species, 4 varieties. Class V has 2 taxa; 2 families, 2 genus, 2 species. Rare plant was 12 taxa; 9 families, 11 genus, 10 species, 2 varieties. Endemic plant was 21 taxa; 17 families, 19 genus, 18 species, 3 varieties. Endangered plant was not present in study area. It was considered that the ecosystem was probably stabilized for nothing of naturalized species and ecosystem disturbance species there. The characteristics of growth environments in the habitats with Allium victorialis var. platyphyllum were considered to be related to valley species and subalpine species such as Actinidia polygama, Cornus controversa, Rhododendron brachycarpum and Sorbus commixta.

A Study on the Distribution and Dynamics of Relict Forest Trees and Structural Characteristics of Forest Stands in Gangwon Province, Korea (강원지역 산림유존목의 분포, 동태 및 생육임분의 구성적 특성)

  • Shin, Joon-Hwan;Lee, Cheol-Ho;Bae, Kwan-Ho;Cho, Yong-Chan;Kim, Jun-Soo;Cho, Jun-Hee;Cho, Hyun-Je
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.2
    • /
    • pp.165-175
    • /
    • 2018
  • The purpose of this study is to provide the basic data such as distribution status, growth characteristics, and the structural characteristics of forest stands for the systematic conservation and management of relict forest trees (stem girth of 300cm or larger) established naturally in Gangwon Province, Korea. The survey showed that 434 individuals of 19 species (conifers: 228 individuals of 4 species, broad-leaved trees: 206 individuals of 15 species) were distributed in Gangwon Province, and Taxus cuspidata was the most abundant among them with 203 individuals or about 46.7 % of the total. The stem girth was average of 404cm (conifers: 373cm, broad-leaves: 421cm), and Tilia amurensis with multi-stemmed growing on Sorak mountain range had the largest stem girth at 1,113cm. The average height and the crown width of relict forest trees were 15.4m and 10.0m, respectively. Although the environments of relict forest trees showed a slight difference by species, the relative appearance frequencies of most trees were high in the environments where the altitude was higher than 1,000 m, slope degree was greater than $25^{\circ}$, the slope faced north, and microtopography was at the upper of slopes. Regarding the stand characteristics of relict forest trees per unit area ($/100m^2$), the average total coverage was 294% (max. 475%), the total average number of species was 36 species (max. 60 species), the average species diversity index (H') was 2.560 (max. 3.593), the average canopy closure was 84.8% (max. 94.6%), and the average basal area (/ha) was $52.7m^2$ (max. $116.4m^2$, relict trees $30.0m^2$, and other trees $22.7m^2$). The analysis of the dynamics of the forest stands where relict forest trees were growing showed four types of the maintenance mechanisms of relict forest trees depending on the supply pattern of succeeding trees: "Low-density but persistent type (Quercus mongolica, Abies holophylla, Tilia amurensis, and Pyrus ussuriensis)," "Long ago stopped type (Pinus densiflora)," "Recently stopped type (Abies nephrolepis, Quercus variabilis, and Betula schmidtii)," and "Periodically repeated types of supply and stop (Salix caprea and Quercus serrata).".

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.

Analysis on the Difference in Perception Between Policy Providers and Users on the Factors that Activate the Innovation Cluster: Focusing on the Case of Daedeok Innopolis using AHP (혁신클러스터 활성화 요인에 대한 정책공급자와 수요자의 인식차이 분석: 대덕연구개발특구 사례에 대한 AHP 조사를 중심으로)

  • Park, Hwogeun;Bae, Kwanpy
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.3
    • /
    • pp.105-119
    • /
    • 2021
  • The innovation cluster is formed by cooperation and networking among a number of actors, including companies, universities, research institutes, government and other supporting organizations, but the main subject of innovation in the venture ecosystem, which can be said to be the core of the innovation cluster, is the enterprise. Therefore, enterprises in innovation cluster can be seen as a major user of the innovation cluster policy. In order for the policy to be executed smoothly, policy acceptance is important. However, existing research on policy prioritization tends to be centered on policy providers, so it is necessary to check them from the perspective of policy users. Accordingly, this study conducted discussions from a two-way perspective to establish the correct policy direction through a balanced perspective between a policy provider-centered top-down perspective and a policy user's bottom-up perspective. First, the factors for activating the innovation cluster (three factors in the first level and 14 factors in the second level) were derived through prior research and expert interviews. After that, the importance of the factors for activating the innovation cluster was analyzed using AHP (Analytic Hierarchy Process) for the policy provider group and the user group in the Daedeok Innopolis, a representative case of innovation cluster policy. As a result of analyzing the importance of the innovation cluster activation factors from the perspectives of policy providers and users, some similarities were also seen, but overall differences in mutual perception were found. It was found that the policy provider group focused on innovation creation factors, while the policy user group viewed innovation creation, clusters, and industrial location factors from a more balanced perspective. This study is meaningful in that it deals with both perspectives in a balanced way by expanding the targets from the existing policy provider-centered research to policy users. In addition, practical contributions exist in the aspect of providing basic data so that policies can be carried out based on corporate needs in fostering innovation clusters.

Sequential Changes in Understory Vegetation Community for 15 Years in the Long-Term Ecological Research Site in Central Temperate Broad-leaved Deciduous Forest of Korea (한반도 온대중부 낙엽활엽수림 장기생태조사지에서 15년간 하층식생 군집의 시계열적 변화)

  • Kim, Min-Su;Yun, Soon-Jin;Park, Chan-Woo;Choi, Won-Il;Chun, Jung-Hwa;Lim, Jong-Hwan;Bae, Kwan-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.3
    • /
    • pp.223-236
    • /
    • 2021
  • This study aims to provide basic data for the systematic conservation and efficient management of forest ecosystems by analyzing changes in understory vegetation of temperate broad-leaved deciduous forests. One-hectare permanent survey plot, consisting of 100 subplots sized 10 × 10 meters, was installed in Gwangneung forest in Pocheon, Gyeonggi-do in 2003. The state of stands and the understory vegetation in the permanent survey plot were examined at a 5-year interval from 2003 to 2018. The vascular plants found in the survey area were 56 families, 128 genera, 176 species, 18 variants, 4 varieties, and 1 subspecies, for a total of 199 taxa. The number of species in both the shrub layer and the herbaceous layer showed a tendency to decrease with time. The MRPP-tests showed a significantly differing species composition of the shrub layer in all years except 2008-2013, whereas significant differences were found in all years concerning the herbaceous layer. As for the average importance value, Euonymus oxyphyllus (18.23%), Acer pseudosieboldianum (16.48%), and Callicarpa japonica (13.85%) were dominant in the shrub layer, while Ainsliaea acerifolia (23.41%), Disporum smilacinum (9.45%), and Oplismenus undulatifolius (5.62%) were dominant in the herbaceous layer. In the shrub layer, the richness of Smilax china, Lonicera subsessilis, and Philadelphus schrenkii was high when the basal area and the stand density of an upper layer were high. By contrast, smaller basal area and stand density were associated with the richness of Acer pseudosieboldianum, Deutzia glabrata, Morus bombycis, and Cornus kousa. Furthermore, it was found out that the impact of the basal area and the stand density on the herbaceous layer decreased over time, while the herb layer's species composition was greatly affected by cover degrees of Euonymus oxyphyllus and Acer pseudosieboldianum in the shrub layer. In conclusion, the number of species in the understory vegetation in Gwangneung forest is continuously decreasing, thus implying that species diversity, basal area, and stand density of an upper layer can influence the species composition in understory vegetation.

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.