• Title/Summary/Keyword: 방화시간

Search Result 120, Processing Time 0.024 seconds

A Study to Hierarchical Visualization of Firewall Access Control Policies (방화벽 접근정책의 계층적 가시화 방법에 대한 연구)

  • Kim, Tae-yong;Kwon, Tae-woong;Lee, Jun;Lee, Youn-su;Song, Jung-suk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.6
    • /
    • pp.1087-1101
    • /
    • 2020
  • Various security devices are used to protect internal networks and valuable information from rapidly evolving cyber attacks. Firewall, which is the most commonly used security device, tries to prevent malicious attacks based on a text-based filtering rule (i.e., access control policy), by allowing or blocking access to communicate between inside and outside environments. However, in order to protect a valuable internal network from large networks, it has no choice but to increase the number of access control policy. Moreover, the text-based policy requires time-consuming and labor cost to analyze various types of vulnerabilities in firewall. To solve these problems, this paper proposes a 3D-based hierarchical visualization method, for intuitive analysis and management of access control policy. In particular, by providing a drill-down user interface through hierarchical architecture, Can support the access policy analysis for not only comprehensive understanding of large-scale networks, but also sophisticated investigation of anomalies. Finally, we implement the proposed system architecture's to verify the practicality and validity of the hierarchical visualization methodology, and then attempt to identify the applicability of firewall data analysis in the real-world network environment.

A Study on the Possibility of Using Fire-Retardant Working Cloth Made from Silicon Carbide (SiC) Composite Spun Yarns (Silicon Carbide (SiC) 복합방적사로부터 제조된 원단의 방화복 활용 가능성에 관한 연구)

  • Kang, Hyun-Ju;Kang, Gun-Woong;Kwon, Oh-Hoon;Kwon, Hyeon-Myoung;Hwang, Ye-Eun;Jeon, Hye-Ji;Joo, Jong-Hyun;Park, Yong-Wan
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.149-156
    • /
    • 2021
  • The mechanical properties of a woven fabric made of SiC (silicon carbide) fibers were determined in this study using the KES-FB system. The woven fabric is used in high heat settings above 1500℃. Composite spun yarns were used to create SiC fibers. By analyzing the wearing properties, we studied the prospect of using the textiles as fire-retardant work clothes. Mechanical properties determine the wearing attributes. Therefore, the tensile linearity (LT), tensile resilience (RT), and shear stiffness (G) values of the fabric varied according to the yarn type (filament or spun yarn). The thickness, weight per square meter, and density of the fabric were found to have an effect on the shear hysteresis (2HG) and compression resilience (RC) values. In terms of wearable clothing qualities, the fabric qualities of the SiC composite yarn demonstrated the highest ratio of compressive energy to thickness (WC/T), which indicates bulkiness. The fabric manufactured from SiC composite yarns passed the KFI criteria for carbonation length and cumulative flame time in the flame-retardant test. Therefore, we discovered that the material can be used as a fire-resistant work cloth.

A Study on Emission Properties of Green House Gas on Duration Combustion of Constructive Wood Materials (건축용 목재의 연소시 지구온난화 가스의 배출특성에 관한 연구)

  • An, Hyung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.123-128
    • /
    • 2018
  • MDF was treated on the surface of MDF with fire retardant lacquer, water-soluble flame retardant coat and water-soluble wood cover on the MDF wood, and the pyrolysis characteristics and the atmospheric noxious gas generation characteristics were investigated by using the large capacity thermal analyzer. As a result of investigating pyrolysis and combustion gas generation characteristics after treatment of 0.11 / 11.55 g in terms of mass ratio, it was found that combustion starting time was slightly longer than that of pure MDF in the case of treatment with fire retardant lacquer. The combustion temperature was increased from $340^{\circ}C$ to $450^{\circ}C$. The pyrolysis and combustion gas generation characteristics of the MDF wood treated with the aqueous flame retardant coat showed the changes in combustion starting time and temperature from $260^{\circ}C$ to $542^{\circ}C$ for about 26 minutes at the mass ratio of 0.13 / 11g. Also, when the commercially available waterproof wood cover was treated with 0.13 / 11.55 g of MDF, the sudden weight change tended to increase from $300^{\circ}C$ to $370^{\circ}C$ and showed a second change at approximately $500^{\circ}C$.

Real-time Network Attack Pattern Analysis System using Snort Log on MapReduce Environment (MapReduce 환경에서 Snort 로그를 이용한 실시간 네트워크 공격패턴 분석 시스템)

  • Kang, Moon-Hwan;Jang, Jin-Su;Shin, Young-Sung;Chang, Jae-Woo
    • Annual Conference of KIPS
    • /
    • 2017.04a
    • /
    • pp.75-77
    • /
    • 2017
  • 최근 급격히 증가하고 있는 네트워크 로그 상에서 보안위협에 신속히 대응하기 위해 기업들은 방화벽, IDS 등의 네트워크 보안 로그를 분석하여 보안 위협을 파악한다. Snort는 이러한 보안 위협에 대응하기 위해 네트워크 로그를 수집하는 도구 중 하나이다. 그러나 보안 관제 담당자는 방대한 양의 보안 관련 로그를 분석하기 위해 많은 시간이 필요하기 때문에, 관제 결과를 보고하고 대응하기까지 시간이 지체되는 문제가 존재한다. 이러한 문제를 해결하기 위해, 본 논문에서는 Snort 로그를 이용한 실시간 네트워크 공격패턴 분석 시스템을 제안한다. 제안하는 시스템은 대용량 데이터 처리에 효과적인 MapReduce 분산 처리를 활용하여 방대한 네트워크 로그를 추출 및 분석하기 때문에 보안 위협 상황 발생 여부를 실시간으로 빠르게 인지할 수 있다.

Fuman behavior during Fire Evacuation in Gosiwon (고시원 화재시 인간 피난행동)

  • Kim, In-Gil;Chung, Yeong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.400-403
    • /
    • 2012
  • 최근 고시원은 저렴한 방값을 원하는 저소득층의 서민들이 주거하는 공간으로서 불특정 다수가 사용하므로 방화의 위험성을 안고 있다. 본 조사는 이 위험성을 검토하기 위해 SIMULEX 실험을 통하여 고시원 화재시 피난행동을 간접적으로 확인 하고 대비 하는데 도움이 되고자한다. 모형실험 결과 재실자들이 1층 출구 대피시 병목현상을 보였지만 연기의 유동은 위로 상승하기 때문에 3층 재실자들의 빠른 대피가 있다면 인명피해는 없을 것으로 판단된다. 만약 이번 실험 조건이 사람들의 인지능력이 떨어지는 시간 조건을 주고 대피시간이 늦는다면 4, 5층의 재실자는 연기의 빠른 확산으로 인해 많은 인명피해가 발생할 수도 있을 것으로 판단된다.

  • PDF

A Study on the Recovery of Lithium from Secondary Resources of Ceramic Glass Containing Li-Al-Si by Ca-based Salt Roasting and Water Leaching Process (Li-Al-Si 함유 유리세라믹 순환자원으로부터 Ca계열 염배소법 및 이에 따른 수침출 공정에 의한 리튬의 회수 연구)

  • Sung-Ho Joo;Dong Ju Shin;Dongseok Lee;Shun Myung Shin
    • Resources Recycling
    • /
    • v.32 no.1
    • /
    • pp.42-49
    • /
    • 2023
  • The glass ceramic secondary resource containing Li-Al-Si is used in inductor, fireproof glass, and transparent cookware and accounts for 14% of the total consumption of Li, which is the second most widely used after Li-ion batteries. Therefore, new Li resources should be explored when the demand for Li is exploding, and extensive research on Li recovery is needed. Herein, we recovered Li from fireproof Li-Al-Si glass ceramic, which is a new secondary resource containing Li. The fireproof glass among all Li-Al-Si glass ceramics was used as raw material that contained 1.5% Li, 9.4% Al, and 28.9% Si. The process for recovering Li from the fireproof glass was divided into two parts: (1) calcium salt roasting and (2) water leaching. In calcium salt roasting, a sample of fireproof glass was crushed and ground below 325 mesh. The leaching efficiency was compared based on the presence or absence of heat treatment of the fireproof glass. Moreover, the leaching rates based on the input ratios of calcium salt, Li-Al-Si glass, and ceramics and the leaching process based on calcium salt roasting temperatures were compared. In water leaching, the leaching and recovery rates of Li based on different temperatures, times, solid-liquid ratios, and number of continuous leaching stages were compared. The results revealed that fireproof glass ceramics containing Li-Al-Si should be heat treated to change phase to beta-type spodumene. CaCO3 salt should be added at a ratio of 6:1 with glass ceramics containing Li-Al-Si, and then leached 4 times or more to achieve a recovery efficiency of Li over 98% from a solution containing 200 mg/L of Li.

Relationship between Autoigniton Temperature(AIT) and Ignition Delay Time for Acids (산(Acid)류의 자연발화온도와 방화지연시간의 관계)

  • 하동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.27-33
    • /
    • 2004
  • An accurate knowledge of the AIT(Autoignition temperatures) of chemicals is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The measurement AITs are dependent upon many factors. namely initial temperature. pressure, volume, fuel/air stoichiometry. catalyst material, concentration of vapor, ignition delay time. This study measured the AITs of acids from ignition delay time by using ASTM E659-78 apparatus which was produced in the year 1994. The experiment AITs were a good agreement with the calculated AITs by the proposed equations with a few A.A.P.E.(average absolute percent error) and A.A.D.(average absolute deviation).

Distributed Contents Delivery Network based on Home gateway for a Sustainable Service (안정적인 서비스를 위한 홈 게이트웨이 기반의 분산 컨텐츠 전송 네트워크)

  • Kim, Myung-Won;Yoon, Young-Hyo;Ko, Joong-Sik;Kwak, Hu-Keun;Chung, Kyu-Sik
    • The KIPS Transactions:PartA
    • /
    • v.15A no.5
    • /
    • pp.249-258
    • /
    • 2008
  • DCDN(Distributed Contents Delivery Network) as known the next generation of CDN is to exploit the resource of client PCs based on P2P technology to provide low cost, high scalability and high speed services when contents are delivered. This DCDN has two problems. One is that DCDN can't provide a sustainable service because client PCs are on/off irregularly and their on times tend to focus on specific time zone, and the other is that client PCs can not be accessed outside in DCDN if they are behind NAT or Firewall. In this paper, we present a distributed contents delivery network based on home gateway for a sustainable service. If home gateway is used in DCDN instead of client PC, it can solve the two existing problems of DCDN. That is, home gateway can provide a sustainable service because it is on during all day and it is not behind NAT and Firewall. The proposed method is implemented with ASUS WL-500GP, a wired/wireless router. Experimental results show the effectiveness of the proposed method compared to the existing method of DCDN.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

Case Study about Performance Based Design through Fire & Egress Simulation for Atrium of A Hotel & Casino (A 호텔 & 카지노 아트리움의 화재 및 피난시뮬레이션을 통한 성능위주설계 사례연구)

  • Park, Chang-Bok;Lee, Yong-Ju;Kim, Min-Ju;Yoon, Myong-O;Choi, Young-Hwa;Park, Jae-Sung;Kim, Hwan-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2009
  • This study is related with fire risk assessment for occupant of the area adjacent to not enclosed atrium through the computer modeling and application of enhanced fire protection systems depending on the result. Fire scenario is intended to evaluate the impact of a fire from atrium base within the corridor adjacent to the atrium and to compare with egress time depending on the warning system. The major purpose of this study is to figure out fire life safety for occupant adjacent to atrium through the computer simulation and to suggest alternative option in case the occupant safety is not guaranteed.