• Title/Summary/Keyword: 방호계

Search Result 84, Processing Time 0.028 seconds

Cyber Defense Analysis and Improvement of Military ecosystem with Information Security Industry (국방 사이버 방호체계 구축 생태계 취약점 분석 및 개선방안)

  • Baek, Jaejong;Moon, Byoung-Moo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1263-1269
    • /
    • 2014
  • Since the cyber defense has been dependent on commercial products and protection systems, in aspect of the recent trends, our cyber defence ecosystem can be more vulnerable. In case of general defense weapon companies, they have to be observed by the government such as certain proprietary technologies and products for the protection from the enemy. On the contrary, most cyber weapon companies have not been managed like that. For this reason, cyber attack can reach to the inside of our military through the security hole of commercial products. In this paper, we enhanced a military cyber protection ecosystems out of enemy attacks and analyze the hypothetical scenarios to evaluate and verify the vulnerability, and finally more securable ecosystem of military protection system is presented politically and technically.

Performance-based Pragmatic Fire Protection Technology by the Control of Fire Triangle at Nuclear Power Plants (화재요인 제어를 통한 원전 성능기반 화재방호 실용화 기술)

  • Jee, Moon-Hak
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.248-252
    • /
    • 2011
  • 화재가 지속되기 위해서는 화재 3요소 또는 4요소가 충족되어야 하지만 역으로 한 개 이상의 화재 요소를 제어하거나 통제할 경우 화재를 진압할 수 있다. 원자력발전소에서는 화재방호계획에 의해 방화지역마다 화재 요인인 점화원, 가연성물질, 산소 등 지연성가스를 분석하고 연속적인 연소반응을 억제할 수 있도록 화재위험 요인을 관리하고 있다. 최근에는 정량화된 화재위험 분석도구인 화재모델을 활용한 성능기반 화재방호 기술이 원자력발전소의 화재리스크 관리를 위해 도입되고 있다. 성능기반 화재위험 분석 방법은 일반 산업계에서도 사용되고 있으나 원자력발전소의 경우 화재로 유발될 수 있는 원자로 손상 가능성을 수치화하고 통제하기 위하여 위험도정보 활용기술과 성능기반 기술을 통합하여 사용하고 있다. 본 논문에서는 원자력발전소의 화재요인 관리 방법을 위험도정보 활용기술과 성능기반 화재방호 기술에 의거하여 분석하는 방법을 제시하였다. 이 분석의 목적은 원자력발전소의 화재위험 관리 방법을 산업계의 화재방호 전문가들이 공유하고 산업계의 특화된 방법과 원자력발전소의 전문화된 분석기술을 실용화하여 화재리스크를 효과적으로 관리할 수 있는 방법을 마련하기 위한 것이다.

  • PDF

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.

Protective Effects of New Herbal Composition (MH-30) against Radiation Injuries in Hematopoietic and Self-Renewal Tissues (생약조성물(MH-30)의 면역조혈계 및 재생조직 방사선 손상에 대한 방호 효과)

  • Jung, Uhee;Park, Hae-Ran;Lee, Ho-Yong;Baek, Ga-Young;Jo, Sung-Kee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.7
    • /
    • pp.948-957
    • /
    • 2016
  • We previously developed an herbal composition (HemoHIM) based on the water extracts of Angelica gigas radix, Cnidium officinale rhizoma, and Paeonia japonica radix to protect and recover hematopoietic and intestinal tissues against radiation injuries. In this study, to develop a composition with improved activities based on enhanced fat-soluble polyphenol contents, we prepared a new herbal composition, MH-30, from the above three herbs by 30% ethanol extraction and hot water extraction. HPLC analysis of the ethanol fractions of MH-30 and HemoHIM revealed that MH-30 had higher contents of many fat-soluble polyphenol compounds than HemoHIM (8.7-fold increase for decursin), whereas contents of water-soluble polyphenol compounds showed little differences between the two compositions. Then, we evaluated MH-30 and HemoHIM for their in vitro antioxidant and immune cell-stimulating activities as well as in vivo protective effects against radiation injuries in hematopoietic and self-renewal tissues. In antioxidant activity assays, MH-30 showed higher hydroxyl radical scavenging activity than HemoHIM (1.4- to 1.9-fold for compositions and 2.3- to 4.5-fold for ethanol fractions). On the other hand, MH-30 and HemoHIM exhibited similar immune cell-stimulating activities as measured by in vitro lymphocyte proliferation. MH-30 increased endogenous spleen colony formation, decreased bone marrow cell apoptosis, and enhanced survival of intestinal crypts in irradiated mice, demonstrating effective protection of MH-30 against radiation-induced injuries in hematopoietic and self-renewal tissues. The 30-day survival rate of lethally irradiated mice, a comprehensive index for radioprotective efficacy, was also elevated by MH-30. Noticeably, MH-30 showed higher protective effects than HemoHIM in all mouse experiments. These results demonstrate that MH-30 can protect hematopoietic and self-renewal tissues against radiation injuries more effectively than HemoHIM. Therefore, MH-30 can be a good candidate to reduce radiation injuries in hematopoietic and self-renewal tissues incurred by radiation accidents or cancer radiation therapy.

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

Developments in Radiation Health Science and Their Impact on Radiation Protection (방사선 보건과학의 발전과 방사선방호에 미치는 영향)

  • Chang, Si-Young;Kim, In-Gyoo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.185-196
    • /
    • 1998
  • 현재의 방사선방호 원칙과 체계는 국제방사선방호위원회 (ICRP)의 권고에 기반을 두고 있 다. ICRP 의 권고는 대부분 히로시마/나카사키 원폭피해 생존자들에 대한 역학조사 및 수명 연구결과 그리고 관련 방사선생물학 연구결과를 바탕으로 전세계 5개 인구집단(일본, 미국, 푸에리토리코, 영국과 중국)에 대한 방사선위험계수의 예측 및 평가결과에 근거를 두고 있다. 이 저선량 방사선의 (확률적 영향) 위험계수는 인체피폭 방사선량과 그 영향간에는 선형 비례관계가 있으며 영향유발의 문턱값이 존재하지 않는다는 가정인 '선형 무문턱값 선량-영향 모델 (Linear No-Threshold Dose-Effect Model, 이른바 LNT 모텔)' 을 도입하여 유도된 것이다(譯者 밑줄). 그러나 이 LNT 가정의 과학적 근거와 정당성에 대한 비난이 원자력산업계나 일부 과학자들에 의해 제기된 이래, 최근에는 미국 보건물리학회 (HPS)에서 'LNT 가정이 선량과 영향의 관계를 단순화하며 낮은 선량의 위험음 과대평가한다'는 성명서를 발표하기도 했다. 이후 이에 대한 논쟁이 다시 시작되어, 1997 년에 스페인의 Sevill에서는 IAEA와 WHO의 공동주최와 UNSCEAR의 협조로 '저준위 방사선 영향에 대한 국제회의'가 개최되기도 하였으나 아직 어느 쪽에도 유리한 결론이 단정적으로 나지 않았으며, 실질적인 대안이 없는 현실에서 이 LNT 가정은 여전히 방사선방호의 철학적 기초로 남아 있다(譯者 밑줄). 한편, 저선량 방사선의 영향에 대해서는 우리나라에서도 '방사선방어학회, ‘98 년 춘계 심포지움' 및 '원자력학회, '98 년 춘계 학술발표회 워크??????'에서 한양대학교의 이재기 교수에 의하여 소개, 논의된 바 있다.이 논문은 이러한 논의의 후속으로 역자중 일인이 위원으로 있는 OECD/NEA 방사선방호위원회 (CRPPH)가 최근에 ('98.7.) 발간한 보고서를 번역, 주해한 것으로, 과학지식의 진보에 따라 방사선방호분야에서 관심이 되는 주제들에 대한 위원회의 검토의견을 소개하고 있다. 따라서 이 논문이 국내의 방사선방호분야 관계자들에게 최신정보 습득과 지식함양에 좋은 도움이 되기를 기대한다.

  • PDF

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.