• Title/Summary/Keyword: 방폭문

Search Result 11, Processing Time 0.022 seconds

FE Analysis on the Structural Behavior of a Double-Leaf Blast-Resistant Door According to the Support Conditions (지지조건 변화에 따른 양개형 방폭문의 구조거동 유한요소해석)

  • Shin, Hyun-Seop;Kim, Sung-Wook;Moon, Jae-Heum;Kim, Won-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.339-349
    • /
    • 2020
  • Double-leaf blast-resistant doors consisting of steel box and slab are application-specific structures installed at the entrances of protective facilities. In these structural systems, certain spacing is provided between the door and wall. However, variation in the boundary condition and structural behavior due to this spacing are not properly considered in the explosion analysis and design. In this study, the structural response and failure behavior based on two variables such as the spacing and blast pressure were analyzed using the finite element method. The results revealed that the two variables affected the overall structural behavior such as the maximum and permanent deflections. The degree of contact due to collision between the door and wall and the impact force applied to the door varied according to the spacing. Hence, the shear-failure behavior of the concrete slab was affected by this impact force. Doors with spacing of less than 10 mm were vulnerable to shear failure, and the case of approximately 15-mm spacing was more reasonable for increasing the flexural performance. For further study, tests and numerical research on the structural behavior are needed by considering other variables such as specifications of the structural members and details of the slab shear design.

FE Analysis on the Structural Behavior of the Single-Leaf Blast-Resistant Door According to Design Parameter Variation (설계변수에 따른 편개형 방폭문의 구조거동 유한요소해석)

  • Shin, Hyun-Seop;Kim, Won-Woo;Park, Gi-Joon;Lee, Nam-Kon;Moon, Jae-Heum;Kim, Sung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.259-272
    • /
    • 2019
  • Steel-concrete single-leaf blast-resistant doors are protective structures consisting of a steel box and reinforced concrete slab. By the domestic blast-resistant doors, the structure is not designed efficiently because few studies have examined the effects of variables, such as the blast pressure, rebar ratio, and steel plate thickness on the structural behavior. In this study, the structural behavior of the doors was analyzed using the FE method, and the support rotation and ductility ratio used to classify the structural performance were reviewed. The results showed that the deflection changes more significantly when the plate thickness increases than when the rebar spacing is a variable. This is because the strain energy absorbed by the door is reduced considerably when the plate thickness increases, and as a result, the maximum deflection becomes smaller. According to a comparison of the calculated values of the support rotation and the ductility ratio, the structural performance of the doors could be classified based on the support rotation of one degree and ductility ratio of three. On the other hand, more explosion tests and analytical studies will be needed to classify the damage level.

Performance Evaluation on Blast-resistant of Gastight Door using Numerical Simulation (수치해석을 활용한 가스차단문의 폭발압력저항 성능평가)

  • Shin, Baegeun;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.27-33
    • /
    • 2022
  • As the scale of explosions diversifies along with the expansion of gas handling and storage facilities, studies on explosion-proof facilities in preparation for accidents is being actively conducted. The gastight door blocks the expansion pressure caused by blast waves or internal fires, and at the same time protects the personnel and equipment inside. For gastight doors, the regulations related to explosion-proof design are not clearly presented, and studies on the explosion pressure resistance performance evaluation of the facility are insufficient. In this study, the gastight door was modeled in a 3D shape with reference to the regulation ASTM regarding the gastight door standard. Afterwards, evaluation for blast-resistant performance of gastight door using Numerical simulation was evaluated by using ANSYS Explicit Dynamics to compare the deformation.

Numerical Analysis of the Subscale Blast Door Deformation and the Subsequent Blast Wave Propagation through the Tunnel by the External Explosion (외부 폭발에 의한 축소형 방폭문 변형 및 터널 내부 폭풍파 전파 거동의 수치해석)

  • Yun, Kyung Jae;Yoo, Yo-Han
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.462-468
    • /
    • 2016
  • In this paper, we present the results of the numerical analysis employing CONWEP, LS-DYNA FSI(Fluid Structure Interaction), AUTODYN FSI, LS-DYNA ALE(Arbitrary Lagrange Eulerian) and combination of CONWEP and LS-DYNA ALE for blast door fracture and wave propagation through the tunnel by the external explosion. We compared the numerical analysis results with the subscale test data and selected combination of CONWEP and LS-DYNA ALE method as adequate data generation method for the FRM(Fast Running Model) software development. It is expected to save much time and costs by using the numerical simulation data for the various test conditions.

A Study on the Calculation of the Design Loads for Blast Doors of Underground Ammunition Facilities Using M&S (M&S를 통한 지하탄약고의 격실 방폭문 내폭력 산정 연구)

  • Park, Young Jun;Baek, Jonghyuk;Son, Kiyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.302-310
    • /
    • 2016
  • An underground ammunition facility requires less quantity distances than the aboveground counterpart. However, chamber blast doors which resist the high blast-pressures are necessary for prevention of the consecutive explosions when an accident explosion occurs at any chamber. This paper aims to propose an procedure for calculation of the design loads for the chamber blast doors. Modeling considerations are drawn through analyzing the influences of the geometrical shapes and mechanical properties of rocks on the propagation of pressure wave along with the tunnels. Additionally, the design loads for the chamber blast doors in a newly-built underground ammunition facility are calculated based on the proposed procedure.

Analysis of Rebound Behavior of Blast-Resistant Door Subjected to Blast Pressure (폭압 작용에 의한 방폭문의 반발거동 해석)

  • Shin, Hyun-Seop
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.6
    • /
    • pp.371-383
    • /
    • 2021
  • Steel-concrete single-leaf blast-resistant doors, having steel box and slab inside, are installed on the wall using supporting members such as hinges and latches. Several studies have been conducted on their deflection behavior in the same direction as that of the blast pressure, but studies on their deflection behavior in the opposite direction, that is, studies on negative deflection behavior are relatively insufficient. In this study, we conducted a parameter analysis using finite element analysis on blast-resistant doors, on their rebound behavior in the negative deflection phase. Results revealed that the plastic deformation of the door, and the change in momentum and kinetic energy during rebound, were major factors influencing the rebound behavior. Greater rebound force was developed on the supporting members in the impulsive region, than in the quasi-static region; due to the characteristics in the impulsive region, where the kinetic energy developed relatively greater than the strain energy. In the design process, it is necessary to consider excessive deformation that could occur in the supporting members as the rebound behavior progresses. Additionally, it was found that in the case of steel-concrete blast doors, the rebound force increased relatively more, when the effects of both rebound and negative blast pressure contributed to the negative deflection of the door. Since conditions for the occurrence of this superposition effect could vary depending on structural characteristics and explosion conditions, further investigation may be required on this topic.

Design consideration and explosion safety of underground ammunition storage facilities (지하탄약고의 설계요소 및 폭발안전 연구)

  • Kim, Oon-Young;Lee, Myung-Jae;Kim, Min-Seok;Kim, Joon-Youp;Joo, Hyo-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.55-70
    • /
    • 2003
  • Ammunition magazine, which is installed on the ground, has difficulty in protecting from the external attack, and accidental explosion should cause great damage to the life and property. For these reasons, it is needed to develop underground magazine that it has the advantages of safety, security and maintenance. This paper introduce the design case for blasting facilities, which should resist blasting pressure, as well as layout of underground magazine, which takes a safety for explosion and a working space of loading/unloading machine into consideration. On the layout, in case of ${\bigcirc}{\bigcirc}$ underground magazine, put three storage chambers in position almost parallel with principle stress direction, where less effected on discontinuity and hard rock area. Also, secured safe distance according to safety criteria of the Defense Ministry, and verified suitable layout by trace simulation for loading/unloading machine on working stage. Blasting design was performed on evaluation of maximum blast pressure between donar and acceptor chambers, and design condition for blast door, valve, etc. Diminution facilities against explosion, such as thrust block or debris trap, determined its size after plan in accordance with blasting criteria and calculation by structural analysis.

  • PDF

A Study on Status Survey for the Improvement of Shelter Facilities for Residents (주민대피시설의 성능개선을 위한 실태조사에 관한 연구)

  • Park, Namkwun;Kang, Shinwook
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • purpose of this study was to conduct status survey on existing shelter facilities for residents and use it as basic material to plan and design improved shelter facilities in the future. As the result, first, although existing shelter facilities are judged to have been designed in consideration only of the protection from high explosive shells, actual protection capability is significantly low against high explosive shells when exit direction and protection capabilities of main entrances were investigated. Second, all the 7 facilities did not have air purifier with filters installed for the air that flows into the inside from outside and since the height of air exhausts and intake pipes in the outside are also close to the earth, there are possibilities that heavy contaminated air can flow into the inside. Third, although some facilities have anti-explosion doors installed, it is impossible to use them as chemical, biological and radiological (CBR) shelter because of improper installation of openings and anti-explosion valves as well as poor plumbing that cannot ensure air-tightness and poor finish of piping penetration.

Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V (AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석)

  • Jeong, Min-Joo;Her, In-Sung;Kang, In-Cheol;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.