• Title/Summary/Keyword: 방출수

Search Result 2,566, Processing Time 0.032 seconds

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF

Hydrothermal Alteration around the Tofua Arc (TA) 25 Seamounts in Tonga Arc (통가열도 TA 25 해저산의 열수변질)

  • Cho, Hyen Goo;Kim, Dong-Ho;Koo, Hyo Jin;Um, In Kwon;Choi, Hunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.169-181
    • /
    • 2014
  • Korea government has consistently investigated the development of economic mineral deposits in the Tofua volcanic arc, Tonga since 2008 for the secure of sea floor mineral resources. We studied the composition and distribution of minerals formed by hydrothermal activity around TA 25 seamounts of the Tofua volcanic arc, Lau Basin, Tonga, using X-ray diffraction analysis, scanning electron microscopy, X-ray fluorescence spectrometry, and inductively coupled plasma atomic emission spectrometry. We used 7 core samples and 9 surface sediment samples. Barite, sphalerite, and clinoclase are present in the most volcanic vent area. Gypsum, smectite, and kaolin mineral are distributed in vent A area, chalcopyrite, pyrite, smectite, and kaolin mineral are in vent B and C area, and gypsum, chalcopyrite, pyrite, and goethite are in vent D area. From the study of clay fraction, smectite and few kaolinite are detected in the most studied area except inner part of caldera, which suggest that argillic alteration are dominant in the volcanic vent areas. Various sulfide or arsenide minerals were found in the hydrothermal vent B, C, and D. The mineralogy and geochemistry suggest higher hydrothermal activities in volcanic vent B, C, and D compared to vent A and inner caldera area. Therefore higher probabilities of massive sulfide deposits may occur in hydrothermal vent B, C, and D.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

THE EFFECT OF RISPERIDONE ON SALIVARY GLAND CELLS (리스페리돈이 타액선 세포에 미치는 영향)

  • Lee, Yeon-Joo;Kim, Yeong-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.47-56
    • /
    • 2008
  • Risperidone is a widely prescribed atypical antipsychotic agent. Approved by the FDA as the first drug to treat irritability associated with autism in children, it is also used to treat tic disorder and Tourette's syndrome. Its adverse reactions related to dentistry include dry mouth, the mechanism of which is yet to be identified. The aim of this study is to identify, at the cellular level, how and to what extent risperidone affects intracellular free calcium concentration ($[Ca^{2+}]_i$), an primary intracellular factor in the regulation of fluid secretion in salivary gland cells. The human salivary gland cell line (HSG) was grown in MEM supplemented with 10% BCS. In order to measure $[Ca^{2+}]_i$, Fura-2/AM was loaded in the HSG, and fluorescence at 340 nm/380 nm excitation was measured in the 500 nm emission ratio. After every experiment, a calibration experiment was conducted in order to readjust the ratio to the actual $[Ca^{2+}]_i$. Changes in $[Ca^{2+}]_i$ were measured in the presence of carbachol, ATP and histamine. The researcher then explored how the pretreatment of risperidone affected such changes. Findings of this study include: 1. In HSG, $[Ca^{2+}]_i$ increased due to the addition of carbachol, ATP and histamine. The presence of risperidone inhibited the action of histamine on this process, while making little effect on that of carbachol and ATP. 2. A quantification of $[Ca^{2+}]_i$ in relation to histamine of different concentrations indicates that the effect of histamine was concentration dependent with an $EC_{50}$ of $3.3{\pm}0.5\;{\mu}M$. 3. The inhibitory effect of risperidone on histamine-induced $[Ca^{2+}]_i$ was concentration-dependent with an $IC_{50}$ of $104.4{\pm}14\;nM$. 4. Risperidone inhibits histamine-induced Ca2+ release from endoplasmic reticulum and influx of extracellular $Ca^{2+}$ in HSG cells(p<0.05).

  • PDF

Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy (근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가)

  • Park, Jeong-Eun;Kim, Kyo-Tae;Choi, Won-Hoon;Lee, Ho;Cho, Sam-Joo;Ahn, So-Hyun;Kim, Jin-Young;Song, Yong-Keun;Kim, Keum-bae;Huh, Hyun-Do;Park, Sung-Kwang
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2015
  • In radiation therapy fields, a brachytherapy is a treatment that kills lesion of cells by inserting a radioisotope that keeps emitting radiation into the body. We currently verify the consistency of radiation treatment plan and dose distribution through film/screen system (F/S system), provide therapy after checking dose. When we check dose distribution, F/S systems have radiation signal distortion because there is low resolution by penumbra depending on the condition of film developed. In this study, We fabricated a $HgI_2$ Semiconductor radiation sensor for base study in order that we verify the real dose distribution weather it's same as plans or not in brachytherapy. Also, we attempt to evaluate the feasibility of QA system by utilizing and evaluating the sensor to brachytherapy source. As shown in the result of detected signal with various source-to-detector distance (SDD), we quantitatively verified the real range of treatment which is also equivalent to treatment plans because only the low signal estimated as scatters was measured beyond the range of treatment. And the result of experiment that we access reproducibility on the same condition of ${\gamma}$-ray, we have made sure that the CV (coefficient of variation) is within 1.5 percent so we consider that the $HgI_2$ sensor is available at QA of brachytherapy based on the result.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Antioxidant Activity of Extract from Walnut Uuglans sinensis Dode) and Its Protective Effect on Cell Injury and Lipid Peroxidation in Renal Cortical Slices (호두 추출물의 항산화 활성과 신피질에서 세포 손상과 지질과산화 방지효과)

  • Bae Kae Sun;Hwang Eul Chul;Kwon Chae Hwa;Kim Soon Hee;Choi Chun Whan
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.106-111
    • /
    • 2005
  • To investigate the antioxidant activity of extract from the raw walnut, Juglans sinensis Dode, we prepared five fractions (methanol (MeOH), dichloromethane $(CH_2Cl_2)$, ethyl acetate (EtOAc), n-buthanol (n-BuOH) and dehydrogen monooxide $(H_2O)$ fractions) and examined. The effect of walnut extract on the oxidative stress was investigated in vitro. The DPPH (2,2-Di (4-tert-octylphenyl)-1-picrylhydrazyl) free radical scavenging activity of extract from raw walnut was shown in the following order: $EtOAc\;fraction layer. The result showed that the highest activity $(0.56{\mu}g/ml,\;IC_{50}.)$ was observed in EtOAc fraction, whereas n-BuOH fraction, MeOH fraction, $CH_2O_2$ fraction and $H_2O$ layer of $IC_{50}$ were $2.34{\mu}g//ml,\;3.88{\mu}g/ml,\;8.06{\mu}g/ml,\;and\;8.19{\mu}g/ml$, respectively. The radical scavenging activity assay of each fraction showed that the antioxidative activity was observed in the following order: EtOAc fraction $(74.27\pm1.56\%)>MeOH\;fraction\;(60.76\pm3.4\%)>n-BuOH\;fraction\;(59.32\pm0.88\%)>H_2O\;layer\;(41.69\pm2.06\%)$. These results revealed that all fractions, except for $CH_2Cl_2$ fraction, showed high antioxidative activity. Furthermore, the peroxynitrite $(ONOO^-)$ scavenging activity was assayed in each fraction. The result showed that the $ONOO^-$ scavenging activity of EtOAc fraction, MeOH fraction and n-BuOH fraction from raw walnut was $95.14\pm0.36\%,\; 90.02\pm1.19\%\;and\;89.41\pm0.81\%$, respectively. The tert-butylhydroperoxide (t-BHP) treatment in vitro increased lactate dehydrogenase release and lipid peroxidation in renal cortical slices. Such changes were completely prevented by addition of MeOH fraction, EtOAc fraction and n-BuOH fraction of walnut. These results indicate that the walnut extract exerts the benedicial effect against t-BHP-induced cell injury and its effect may be due to antioxidant action. In addition, it is suggested that walnut extract might be developed as the effective scavenger for the prevention of oxidative stress.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Variation of Lead Content in Paddy Rice and Soil of Janghang Smelter Area (장항제련소 지역의 토양과 수도체 중 Pb 함량의 변화에 관한 연구)

  • Kim, Seong-Jo;Ryu, Taek-Kyu;Lee, Man-Sang;Yang, Chang-Hyu;Jeon, Kyung-Soo;Beak, Seung-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.3
    • /
    • pp.185-193
    • /
    • 1992
  • To investigate differences in lead content in soils and paddy rices, affected by air pollutants from the Janghang Smelter, soil samples at the different directions, distances, and depths, surface(0-15cm depth) and subsurface(15-30cm depth) in 1982 and 1990, and rice plants at soil sampling sites in 1990 were separately collected at the Janghang Smelter area affected by combustible waste gas from the smelter chimney. Soil samples were extracted with $4M-HNO_3$ and plant samples were digested with mixture of $HNO_3$ and $HCIO_4$ for analyzing by atomic absorption spectrophotometry. The Pb contents in soils ranged from 10.3 to 644.8mg $kg^{-1}$. The average content in 1990 was higher than that in 1982. The Pb content in soils at sites nearer the center of the smelter was higher than that at sites farther from the center. The highest lead content was found at the east direction, and was low in order of east>north-north east>north east > north. The variation of Pb level in soils at east sites was more considerable than other directions. The Pb level in surface soils was higher than that in subsurface soils. The contaminated radius of Pb was until 3km all at east, north-north east and north east. A significant correlation was found between Pb content in surface soils of 1982 and that in surface soils of 1990, between Pb content in soils and contents of Cd and Zn in soils, and between Pb content in soils and soil properties as organic matter, available silicate, cation exchange capacity, exchangeable $Ca^{++}$, $Mg^{++}$ and $Na^+$. Pb content in brown rice was low in the panicle axis, and brown rice, and Pb content in stem was 3.26 times of that in brown rice. Pb content in brown rice ranged from 2.2 to 9.0 mg $kg^{-1}$.

  • PDF

Evaluation and Consideration on Environmental Radiation Analysis of Yeong-Gwang Nuclear Power Plant Site Inside&Outside(2000~2009 year) (영광원전 부지 내.외부의 환경방사능 분석에 대한 평가 및 고찰(2000~2009년))

  • Han, Sang-Jun;Lee, Seung-Jin;Lee, Goung-Jin;Lee, Na-Young;Kim, Hee-Gang;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.71-78
    • /
    • 2011
  • Yeong-Gwang N.P.P Private Environment Supervisory Organization analyzed over 3,000 samples including 10 marine and 24 land samples from the year 2,000 to 2009. According to the results of the analysis, artificial nuclides that resulted from the effect of Yeong-Gwang Nuclear Power Plant operations were not detected in most samples. However, from the rain and seawater samples, which were taken from inside the plants such as the intake, the discharge and the observatory, $^3H$ was detected although it was below the regulation level. The $^3H$ concentration detected in the rain taken from the observatory, by the yearly average criterion, was 30.5~40.0 $Bq{\cdot}L^{-1}$, which is around 20 times the $^3H$ concentration detected in the surroundings of the power plants, but it is 0.1% of the regulation level of 40,000 $Bq{\cdot}L^{-1}$. Also, $^3H$ concentration detected in the seawater taken from the intake and the discharge, by the yearly average criterion, was 2.75~17.8$Bq{\cdot}L^{-1}$, which means the concentration detected in the discharge is about 140~280% higher than that detected in the intake except the year 2006. Based on these results, it was determined that, although lower than the regulation level, the $^3H$ in gas and liquid form detected in the rain and seawater sampled from the observatory and the discharge was released into the environment from the power plants. Therefore, regular monitoring and analysis is required on the level of $^3H$ in the observatory and the discharge.