• Title/Summary/Keyword: 방출강도

Search Result 289, Processing Time 0.024 seconds

Application of Acoustic Emission Technique and Friction Welding for Excavator Hose Nipple (굴삭기용 호스 니플의 마찰용접과 음향방출기법의 적용)

  • Kong, Yu-Sik;Lee, Jin-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.436-442
    • /
    • 2013
  • Friction welding is a very useful joining process to weld metals which have axially symmetric cross section. In this paper, the feasibility of industry application was determined by analyzing the mechanical properties of weld region for a specimen of tube-to-tube shape for excavator hose nipple with friction welding, and optimized welding variables were suggested. In order to accomplish this object, friction heating pressure and friction heating time were selected as the major process variables and the experiment was performed in three levels of each parameter. An acoustic emission(AE) technique was applied to evaluate the optimal friction welding conditions nondestructively. AE parameters of accumulative count and event were analyzed in terms of generating trend of AE signals across the full range of friction weld. The typical waveform and frequency spectrum of AE signals which is generated by friction weld were discussed. From this study the optimal welding variables could be suggested as rotating speed of 1300 rpm, friction heating pressure of 15 MPa, and friction heating time of 10 sec. AE event was a useful parameter to estimate the tensile strength of tube-to tube specimen with friction weld.

Improment of Diesel Combustion using multiple injection under Cold Start Condition (냉시동 조건에서 디젤 연소 특성 및 연소 개선에 대한 연구)

  • Lee, Haeng-Soo;Lee, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.711-717
    • /
    • 2017
  • Startability and harmful emissions are the main issues in diesel engine development under cold conditions. The characteristics of combustion with multiple injection were investigated under cold start conditions. For quantitative analysis, the in-chamber pressure profile was measured and combustion visualization using direct imaging was accomplished. With multiple injection, the peak in-chamber pressure and heat release rate were increased compared to single injection. In addition, the period of flame luminosity detection was shortened using multiple injection. Combustion by main injection was improved with an increase in heat released by pilot combustion when the pilot injection quantity was increased. Finally, an increase in injection pressure also showed the possibility of combustion improvement. On the other hand, an increase of in the pilot injection quantity and injection pressure can cause an increase in harmful emissions, such as HC and CO due to wall wetting. Therefore, more sensitive calibration will be needed when applying a multiple injection strategy under cold start conditions.

SHEAR BOND STRENGTH OF GIOMER AND SELF-ETCHING PRIMER ON THE DENTIN (Giomer와 자가 산부식 접착제의 상아질에 대한 전단 결합강도)

  • Yoon, Eun-Young;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.422-428
    • /
    • 2010
  • Giomer is fluoride-releasing, resin-based dental materials that comprise PRG(pre-reacted glass ionomer) filler. The purpose of this study was to evaluate the shear bond strength of Giomer using self-etching primer systems to bovine dentin. Bovine incisors were mounted in self-curing orthodontic resin and the facial surfaces were wet ground on SIC paper to expose the dentin. Total 100 samples were made and divided randomly into 4 groups, Giomer group(I), Composite resin group(II) and Compomer group(III), Giomer and single bottle adhesive group(IV). The shear bond strengths of 25 samples per each group were measured using universal testing machine. And data were analyzed statistically with One-way ANOVA and Scheffe test. Giomer group(I) showed the significantly higher bond strength than Compomer group(III)(p<0.05). There was no significant difference between Giomer group(I) and Composite resin group(II)(p>0.05). And there is no significant difference between gourp(I) and group(IV). Based on the results of present study, the use of Giomer as an esthetic restorative material for primary teeth might be justified. It is considered that more study about the fluoride releasing ability is needed to evaluate the anticariogenic effect of giomer.

Self-Sensing of Single Carbon Fiber/Carbon Nanotube-Epoxy Composites Using Electro-Micromechanical Techniques and Acoustic Emission (전기적-미세역학시험법과 음향방출을 이용한 단일 탄소섬유/탄소나노튜브-에폭시 나노복합재료의 자체-감지능)

  • Park, Joung-Man;Jang, Jung-Hoon;Wang, Zuo-Jia;Kwon, Dong-Jun;Park, Jong-Kyu;Lee, Woo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.411-422
    • /
    • 2010
  • Self-sensing on micro-failure, dispersion degree and relating properties, of carbon nanotube(CNT)/epoxy composites, were investigated using wettability, electro-micromechanical technique with acoustic emission(AE). Specimens were prepared from neat epoxy as well as composites with untreated and acid-treated CNT. Degree of dispersion was evaluated comparatively by measuring volumetric electrical resistivity and its standard deviation. Apparent modulus containing the stress transfer was higher for acid-treated CNT composite than for the untreated case. Applied cyclic loading responded well for a single carbon fiber/CNT-epoxy composite by the change in contact resistivity. The interfacial shear strength between a single carbon fiber and CNT-epoxy, determined in a fiber pullout test, was lower than that between a single carbon fiber and neat epoxy. Regarding on micro-damage sensing using electrical resistivity measurement with AE, the stepwise increment in electrical resistivity was observed for a single carbon fiber/CNT -epoxy composite. On the other hand, electrical resistivity increased infinitely right after the first carbon fiber breaks for a single carbon fiber/neat epoxy composite. The occurrence of AE events of added CNT composites was much higher than the neat epoxy case, due to micro failure at the interfaces by added CNTs.

The Initiation of Slip on Frictional Fractures (마찰 전단면의 전단거동과 에너지방출률)

  • Park, Chi-Hyun
    • Tunnel and Underground Space
    • /
    • v.20 no.5
    • /
    • pp.344-351
    • /
    • 2010
  • Slip along a frictional fracture can be approached as initiation and propagation of a mode II crack along its own plane. Fracture mechanics theories predict that under pure mode II loading initiation will occur when the energy release rate of the fracture attains a critical value ($G_{IIC}$), which is generally taken as a material property. For the past few years the rock mechanics group at Purdue University has investigated experimentally the dependence of $G_{IIC}$ on normal stress and on the frictional characteristics of a fracture. A number of experiments has been conducted first on acrylic, a material that, using photoelastic methods, allows visualization of the stress field ahead of the fracture tip; and later on gypsum, a rock model material with relatively low unconfined compression strength. The experimental investigation has been expanded to include other frictional materials with higher unconfined compression strength. Direct shear tests have been conducted on specimens made with cement paste. New observations together with previous experiments indicate that $G_{IIC}$ can only be considered a material property when the peak friction angle of the discontinuity is similar to the residual friction angle; otherwise the critical energy release rate increases with normal stress.

Combustion Characteristics of the 5 Herb Species in Youngdong Areas (영동지역 5개 초본 수종의 연소특성)

  • Lee, Hae Pyeong;Lee, Si-Young;Park, Young Ju
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.290-296
    • /
    • 2009
  • In this study, we considered the combustion of the various herbs in youngdong areas such as festuca ovina, isodeon japonicus, oplismenus undulatifolius, pueraria thunbergiana, and cirsium japonicum var. ussuriense using the ignition temperature tester, cone calorimeter, smoke density chamber. We confirmed that the range of ignition temperature was $400{\sim}455^{\circ}C$ and the time to ignition and flameout were not recorded. The total heat release of isodeon japonicus was highest and the smoke release of festuca ovina was highest, and the yield of CO and $CO_2$ of pueraria thunbergiana, and cirsium japonicum var. ussuriense were highest among the samples. As a result, we concluded that isodeon japonicus will impact the fire intensity and fire spread and festuca ovina, pueraria thunbergiana, and cirsium japonicum var. ussuriense will influence the refuge.

Studies on Adhesion of Fancy Veneer and Formaldehyde Emission of Wood-Based Floorings by Mole Ratios of Urea and Melamine (요소·멜라민 접착제의 수지 조성에 따른 마루판의 천연무늬단판 접착성 및 포름알데히드 방출에 대한 연구)

  • Kang, Eun-Chang;Park, Jong-Young;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • This study was to investigate the adhesion properties of fancy veneer and base panels and formaldehyde emission of wood-based floorings bonded with urea-melamine formaldehyde adhesives. We focused on stoichiometric mole ratio of reactive functional groups. The urea-melamine formaldehyde adhesives were made at twelve different formaldehyde/urea-melamine mole ratios. The interlaminated shear strength and formaldehyde emission of wood-based floorings bonded with selected adhesive among these adhesives were examined. The results showed that the bonding properties were high and the formaldehyde emission was low as the adhesive consisted of stoichiometric mole ratio of formaldehyde/urea-melamine. Interlaminated shear strengths of HDF(High Density Fiberboard) flooring were over 14 kgf/cm2 at all mole ratios. At the mole ratio of 1.0, HDF flooring showed low value of formaldehyde emission of 953 mg/L. Interlaminated shear strengths of Plywood flooring were high, 14.02 kgf/cm2 at mole ratio of 1.4. At the mole ratio of 1.0, Plywood flooring showed low value of formaldehyde emission of 0.26 mg/L.

Optimization of Bar-to-Bar Dissimilar Friction Welding of Hydraulic Valve Spool Steel and the Weld Strength Properties and Its AE Evaluation (유공압 밸브 스풀용 강재의 봉대봉 이종재 마찰 용접 최적화와 용접강도 특성 및 AE 평가)

  • 오세규;유인종;박형동;이연탁
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.24-33
    • /
    • 1996
  • Up to now, most of studies on mechanical properties in friction welded components are about tensile and bending strength. However the fatigue studies on the friction-welded components subjected to repeated stress are not available. The purposes of this study are the development of fundamental design and the development of in-process real-time weld quality evaluation technique by acoustic emission for the bar-to-bar dissimilar friction welding of hydraulic valve spool steels.

  • PDF

어쿠우스틱 에밋션法 에 依한 摩찰熔接 强度解析 (I)

  • 오세규
    • Journal of the KSME
    • /
    • v.22 no.3
    • /
    • pp.184-190
    • /
    • 1982
  • 어쿠우스틱 에밋션(AE)법에 의한 마찰용접강색도의 공정중 해석에 관한 실험적 연구에서의 탐 색적 연구결과는 다음과 같은 예비적 결론으로 나타내진다. 1) 철금속의 만족한 마찰동정을 달성할 때는 두개의 AE 돌출이 나타난다. 그 하나는 A역인 용 접사이클 중에 일어나는 것이며, B역인 또 다른 하나는 용접종료후 2, 3초 지나서 시작되는 냉 각중의 돌출이다. 최초의 돌출은 주로 재료의 소성변형에 기인하며, 두 번 째 AE 방출은 일반 적으로 크기가 더 크며 냉각중의 마르텐사이트 변태의 결과라고 해석된다. 2) AE의 초량과 강의 마찰용접강도 사이에는 일정한 상관관계가 존재한다고 생각된다. 실험적 오차를 더욱 감소시킨다면 정량관계가 수립될 수 있을 것이다. 3) 트랜스듀서와 기타 부품의 적절한 선택에 의해 철금속의 마찰용접품질(강도)을 공정중에 탐 색하기 위한, AE 법에 의한 공정중 용접강도 해석 시스템의 개발 가능성이 있다.

  • PDF

Microwave Radiometry for functional Diagnosis of Biological tissue (생체 기능적 진단을 위한 Microwave Radiometry의 응용)

  • Lee, J.W.;Kim, K.S.;Lee, S.M.;Yoon, G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.845-847
    • /
    • 2000
  • 깊은 생체 조직에서 전자기 에너지의 일부가 피부로 전달되는데, 이때 생체 내부에서 피부로 전달되는 전자기 에너지의 세기는, 주파수 대역과 전자기파를 흡수, 반사, 투과시키는 인체의 매질에 따라 다르다. Microwave Radiometry는 인체 내부 조직에서 방출되는 1-6 GHz 대역의 전자기 에너지 일부를 피부 표면에서 측정하여 일정한 체적내의 인체 내부 온도 평균온도를 추정하는 방법이다. 이러한 Radiometry로 암이나 종양 등의 이상 조직을 진단하는 의학적 가설은, 암이 진행시 악성 종양의 세포의 신진대사가 정상 세포보다 활발하게 되고 또한 종양 세포 주위로 혈액의 유입이 증가하게되어, 주위의 정상 세포 보다 열을 보다 더 방출하는 데 있다. 이때 발생된 열은 일정한 주파수 대역의 마이크로파 에너지를 방출하게 되고, 이에 Radiometry로 인체에 무해하고(passive), 비침습적(non-invasive), 방사능의 영향이 없는 (non-ionizing) 방법으로 인체 내부에서 전달되는 전자기 에너지 강도를 측정하여 종양 부위와 주위 정상부위의 온도 차이를 추정 의학진단에 응용할 수 있다. 본 논문에서는 이러한 Microwave Radiometry의 의학적 응용과 생리학적 특성을 고려한 인체모델용 팬텀에 대하여 살펴본다.

  • PDF