The Evaluation of Location Decision Factors of Environmental Foundation Facilities using Environmental Geographic Information System (환경지리정보시스템을 이용한 환경기초시설의 입지 결정요인 평가)

  • Cho, Deok-Ho;Bae, Min-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.1
    • /
    • pp.45-57
    • /
    • 2008
  • The purpose of this research is to select an appropriate location of water pollution prevention facilities(WPPF) through evaluating location decision factor using environmental geographic information system. To do that, this research reviewed the current location policies of WPPFs and its related researches. And this paper builds water pollutant statistical databases, integrated them with the geographic information system of the administrative areas where water pollutants are generated, and gears it with statistical programs such as correlation and regression analysis in order to figure out the pollution factors which influence on the location decision of WPPF on the real time base. The volume of discharge of industrial wastewater is one of the most important water pollutants on the location decision of WPPF. And the number of industrial facilities also was the most important location decision factor in constructing the WPPFs. In addition, this paper noted that the number of population in each area makes a role to restraint the construction of WPPF. It identified that the disposal facility in Nackdong river upper-middle watersheds was insufficient in treating the livestock pollutants. Therefore, Gyeongbuk should concentrate on the construction of disposal facilities of livestock pollutant in these areas. The results of this research will contribute to decide what kinds of WPPF should be constructed on which watershed in Nackdong River, and to forecast the future water quality of each watershed.

  • PDF

A Study on the Properties comparison of the PVC Net and Expanded Metal Using Rockfall Protection Net Pullout Test Equipment (낙석방지망 인발시험을 이용한 PVC망과 Expanded Metal 특성비교에 관한 연구)

  • Cheon, Seongyeol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • The governmental investment to SOC facilities currently has increasedthe construction of new roads and the consistent extension of already-existing roads or the line-shape revision of those roads. As a result, the road cut slopes have been increasingrapidly. Unfortunately, human-life damages and property damages frequently occur due to the rockfall and the landslide every year. To reduce those damages, many studies have been performed. The present regulation regarding rockfall protection facilities follows the "Guide for Installation and Management of Road Safety Facilities" issued by MLTM (the Ministry of Land, Transport, and Maritime Affairs) that indicates the standard size of facilities and energy absorbing efficiencies. Most domestic road slopes use standardized rockfall protection facilities based on the regulation. However, there have been doubted about the effectiveness of rockfall protection facilities and the damages caused by rockfalls havebeen increasedevery year. Thus, it seems that relevant studies are necessary on the rockfall protection net being capable of supporting rockfall energies. Accordingly, this study reviews previous literature to investigate the function and the feature of rockfall protection nets and analyzetheir limitations by each type. After that, by using the pullout test device for a rockfall protection net, an experiment on the PVC coating net and the expanded metal is performed under the exact same condition. Finally, the features of the Expended metal is explained with the comparison analysises of load-variation and the confirmation of damaged forms. As a result, there have been founded the problemsof net breaking down and not being able to support due to PVC coating net's material property of disintegration. On the other hand, the Expanded Metal might be expected as a substituteof rockfall protection net according to its capability of support and integration.

  • PDF

Studies on the Isolation of Antioxidative Components of Perilla Oil (들기름의 산화방지 성분 분리에 관한 연구)

  • Kim, Choong-Ki;Song, Geun-Seoup;Kwon, Yong-Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.690-695
    • /
    • 1994
  • The perilla seed and the germinated perilla seed $(25{\sim}28^{\circ}C$, $2{\sim}3\;days)$ were extracted by n-hexane, and from the extracted oil the antioxidative components were separated, and then the effect of the change in the contents of antioxidative components by germination on the oxidative stability of the perilla oil was studied. The perilla oils were solved acetone and methanol, and kept at $-60^{\circ}C$ overnight and separated into the frozen oil fraction and unfrozen solvent soluble fraction. By comparing the antioxidative stability of the frozen oil fraction the antioxidative components in the perilla oil were found to be methanol soluble. The methanol soluble fraction of perilla oil was applied to silica gel column chromatography and the separated fractions were compared in terms of antioxidative activity. The fraction of n-hexane : ethyl acetate (7 : 3, v/v) showing the highest antioxidative activity was further separated by TLC. The components included in the band $(R_f\;0.71)$ showing the highest antioxidative activity was separated by HPLC. Four peaks were observed on the HPLC chromatogram and the peak areas were changed by germination (perilla seed : peak 1; 46.5%, peak 2; 25.6%, peak 3; 22.6%, germinated perilla seed : peak 1; 43.8%, peak 2; 20.6%, peak 3; 29.8%). The comparative change in the contents of these components was considered to be one factor affecting the antioxidative stability of perilla oil by germination.

  • PDF

Development of Buckling Restrained Brace Laterally Supported by Semicircular Springs (반원형 스프링으로 횡지지된 건식형 좌굴방지가새의 개발)

  • Park, Keum Sung;Lee, Sang Sup;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.549-558
    • /
    • 2014
  • Buckling restrained braces(BRBs) developed as a seismic protection element, hysteretic damper, have been investigated in America and Japan mainly. BRBs are composed of a steel core and concrete-filled steel casing. It is one of the major causes of drop in productivity to fill the steel casing with concrete. To improve this problem, the BRB is introduced in which the steel core is restrained with a pair of semicircular springs. In this paper, the numerical and analytical investigation about the desirable configuration for a semicircular spring is presented. Firstly, the stiffness and strength of semicircular spring is determined theoretically to buckle into a very high-order modes. Then, the required stiffness and strength are calculated under the practical design conditions and considered as reference values to find a proper configuration. The material strength and thickness of semicircular spring are chose from the finite element analysis for 5 semicircular springs with varying height. Finally, the nonlinear buckling analysis of BRB with proper semicircular springs shows that the bucking strength of the whole BRB is very similar to the strength of steel core with length between semicircular springs.

Enactment of Anti-terrorism law In the Third World And The Instruction for Us (제3세계 국가의 테러방지법제정과 우리나라에 있어서 시사점)

  • Cho, Sung-Je;Soung, Jea-Hyen
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.274-283
    • /
    • 2009
  • To effectively and quickly respond to new forms of terrorism, a more organically integrated and coordinated system will be needed. As establishing the grounds of such a system based on laws would be most in congruence with legalism, it would be desirable to fundamentally establish an antiterrorism act. However, enactment of such counter-terrorism laws must be accomplished by means with which human rights violations against citizens may be minimized, contrary to what has been the case with third world nations. The act will need to include clauses that may relieve organizations, such as national human rights committees or citizen groups, of concerns over potential human rights violations. To address vulnerabilities of investigative rights issues which relate to cases relevant to acts of terrorism being delegated to the National Intelligence Service, the investigative jurisdiction shall be assigned to the public prosecutors and law enforcement officials as with other criminal proceedings. As for public concern that establishing the Anti-Terrorism Center under the National Intelligence Service, a secret service agency, may infringe upon human rights, functional and organizational dualism of the Anti -terrorism Center would be worth taking into account.

Development of a Systemized Flying Net for Safety Improvement in Architectural Building Construction (건설 공사의 안전성 향상을 위한 충돌방지형 시스템 플라잉넷의 개발)

  • Lee, Jeong-Ho;Park, Seon-Joo;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.5
    • /
    • pp.71-80
    • /
    • 2011
  • Flying net should be installed on every 3 or 4 construction floor from 8m above ground according to the rule. In the apartment housing construction, flying net installation work has been recognized the most dangerous work among the whole works because a small mistake of labors might make their death accident. Sub-contractors specialized in flying net have been developing various flying net types. However, most works of installing flying net as working with the developed system are performed outside the apartment housing, so that the risk of fall in works of installing supports and unfolding net is still high. Furthermore, as using the previously developed flying net labors might bump into the frame or the wire rope for supporting so that it makes secondary accidents. The objective of this research is to produce the proto-type of anti-collision flying net system based on the result of problem analysis on the installation and detachment process and suggest the improved anti-collision flying net system, which is able to improve safety and field applicability by conducting field experiment and analyzing performance.

Research on Cognition of Infection Control by Dental Hygienics Student's in some Areas (일부 지역 치위생학과 학생들의 감염방지에 관한 인식 조사)

  • Moon, Seon-Jeong;Ku, In-Young
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.313-320
    • /
    • 2012
  • A dental treatment room is always exposed to diverse kinds of pathogenic bacteria, and may be a mediating place of cross-infection given being contaminated the interior of a room through several routes in the form of patient's secretion and aerosol. The main agent of preventing cross-infection is a dental hygienist in the dental treatment and the dental treatment room where are scattered about a risk of cross-infection. A dental hygienist needs to have right recognition on infection control before being active as a clinical expert. This infection-control recognition level is influenced from the clinical practice. Accordingly, to survey recognition of infection control, a self-administered questionnaire research was conducted targeting 314 students who are fixed the clinical practice as regular subject in the junior course out of curriculum for the Department of Dental Hygiene at some of 4-year universities. Data collection was performed from December 9, 2011 to February 22, 2012. Except 11 copies of questionnaire with insincere response among the collected materials, 303 copies were finally analyzed by using SPSS WIN 20.0. The following conclusions were obtained. In the infection disease section, both on and off campus showed 4.89 points from 'the importance of recognizing the infections prevention', 4.65 points from 'recognizing the compulsory preventative injection for hepatitis type B', 4.77 points from 'recognizing the necessity of the preventative injection for hepatitis type B', 4.71 points from 'whether practice the prevention in reality or not', and 4.76 points from 'the educational helps to the prevention'. In other words, the section recorded the highest and meaningful points. It is considered to be needed the development in systematic and diverse infection-control educational programs and the differentiated education depending on school year for dental hygiene students.

Diffusion barrier properties of Mo compound thin films (Mo-화합물의 확산방지막으로서의 성질에 관한 연구)

  • 김지형;이용혁;권용성;염근영;송종한
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.143-150
    • /
    • 1997
  • In this study, doffusion barrier properties of 1000 $\AA$ thick molybdenum compound(Mo, Mo-N, $MoSi_2$, Mo-Si-N) films were investigated using sheet resistance measurement, X-ray diffraction(XRD), X-ray photoelectron spectroscopy(XPS), Scanning electron mircoscopy(SEM), and Rutherford back-scattering spectrometry(RBS). Each barrier material was deposited by the dc magnetron sputtering and annealed at 300-$800^{\circ}C$ for 30 min in vacuum. Mo and MoSi2 barrier were faied at low temperatures due to Cu diffusion through grain boundaries and defects in Mo thin film and the reaction of Cu with Si within $MoSi_2$, respectively. A failure temperature could be raised to $650^{\circ}C$-30 min in the Mo barrier system and to $700^{\circ}C$-30 min in the Mo-silicide system by replacing Mo and $MoSi_2$ with Mo-N and Mo-Si-N, respectively. The crystallization temperature in the Mo-silicide film was raised by the addition of $N_2$. It is considered that not only the $N_2$, stuffing effect but also the variation of crystallization temperature affects the reaction of Cu with Si within Mo-silicide. It is found that Mo-Si-N is the more effective barrier than Mo, $MoSi_2$, or Mo-N to copper penetraion preventing Cu reaction with the substrate for $30^{\circ}C$min at a temperature higher than $650^{\circ}C$.

  • PDF

An Alternative Effectiveness Analysis on Anti-Dew Road Sign (도로표지판의 결로 방지 대안별 효과 분석)

  • Park, Jae-Hong;Yun, Duk-Geun;Sung, Jung-Gon;Kang, Weon-Eui
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.55-61
    • /
    • 2012
  • Road signs are important facilities in terms of providing information to driver, they are helpful for driver's judgment as deliver it's own information. However if there is occurrence dew on the road sign because of the change of temperature and humidity, it can be cause of accidents. Therefore it is necessary to develop anti-dew or dew resistance technology. In this research the anti-dew technologies such as insulation road sign and anti-dew film were compared with normal road sign, and the effectiveness analysis was conducted for each alternatives. The quantity of dew on the road sign was check using ANOVA and Tukey HSD and the relation between the retro-reflectivity and quantity of dew on the sign was check using Pearson correlation coefficient. As a result, the sample of anti-dew film attached road sign showed lesser quantity of dew compared with normal road sign. After 90 seconds, the difference of dew quantity for anti-dew film and insulation road sign showed statistically significant result. The relation of between quantity of dew and retro-reflectivity was inverse correlation. As a result, when analyzed the quantity of dew and retro-reflectivity a point of view anti-dew effectiveness, the anti-dew film and insulation road sign showed meaningful result.