• Title/Summary/Keyword: 방음벽 기초

Search Result 10, Processing Time 0.024 seconds

Deterioration Evaluation Method of Noise Barriers for Managements of Highway (고속도로 방음벽 유지관리를 위한 방음벽 노후도 평가 방안)

  • Kim, Sangtae;Shin, Ilhyoung;Kim, Kyoungsu;Kim, Daae;Kim, Heungrae;Im, Jahae;Lee, Jajun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.4
    • /
    • pp.387-399
    • /
    • 2019
  • This research aimed to prepare the classification of the damage types and the damage rating system of noise barriers for expressway noise barriers and to develop deterioration evaluation method of noise barriers by reflecting them. The noise barrier consists of soundproof panels, foundations and posts and the soundproof panels with 10 different types of materials are used in a single or mixed form.In this paper, damage of soundproof panel shows a single or composite damage, and thus a evaluation model of deterioration has been developed for noise barriers that can reflect the characteristic of noise barriers. Materials used mainly for soundproof walls were divided into material types for metal, plastic, timber, transparent and concrete. And damage types for noise barrier were classified into corrosion, discoloration, deformation, spalling and dislocation and damage types were subdivided according to the noise barrier's components and materials. Damage rating was divided into good, minor, normal and severe for each major part of noise barrier to assess damage rating of soundproof panel, foundation and post. The deterioration degree of noise barrier was evaluated comprehensively by using the deterioration evaluation method of whole noise barrier using weighted average. Deterioration evaluation method that can be systematically assessed has been developed for noise barrier using single or mixed soundproof panel and noise barrier with single or complex damage types. Through such an evaluation system, it is deemed that the deterioration status of noise barrier installed can be systematically understood and utilized for efficient maintenance planning and implementation for repair and improvement of noise barriers.

A preliminary study on the measurement method for determining the absorption coefficient of sound barrier panels (방음판의 흡음률 측정방법 제안을 위한 기초 연구)

  • Yang Ki Oh;Ha Geun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.152-160
    • /
    • 2023
  • Sound barrier walls are the most basic way to cope with noise problems in urban residential environments. The most important acoustic function of sound insulation board is represented by sound transmission loss and sound absorption coefficient. However, Korea has not yet established a standard for measuring the sound absorption rate of sound insulation boards. In addition, even in the European standard, where the overall acoustic standard of soundproofing boards has already been established, the sound absorption rate is applied only to the standard for measuring the sound absorption rate of general building finishing materials, and a separate measurement method considering the characteristics of soundproof walls and soundproofing boards is not presented. The sound absorption coefficient should be evaluated by summing up the energy absorbed into the material as well as the energy transmitted through the material, but the current European standard has a problem in that the transmitted sound energy is not taken into account. In this paper, we reviewed the sound absorption coefficient measurement standards of sound insulation boards currently being presented, and verified the difference between the results and the new measurement method considering transmission sound for sound insulation boards actually used in Korea.

A Study of Sound Pressure Characteristics of Error Sensors by Position in Active Noise Barrier Development (능동형 방음벽 개발을 위한 에러센서 위치 연구)

  • Cha, Sang-Gon;Kim, Dong-Hwan;Troshinun, Andrey;Choi, Jang-Cheol;Shin, Eun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1756-1757
    • /
    • 2011
  • 본 논문에서는 FXLMS 알고리즘을 이용하여 3차원 폐공간(반무향실)에서의 순음(125Hz)을 이용하여 부 음원과 에러센서의 위치 변화에 따른 소음저감 정도를 분석하였으며, 이 결과를 바탕으로 능동형 방음벽의 구현의 기초자료로 활용하고자 하였다. 부음원(제어스피커, 이하 부음원)과 에러센서간 거리차는 0.5m, 1.5m, 2.5m를 대상으로 실험을 실시하였으며 그 중 거리차가 1.5m 지점의 경우, 125Hz부근에서는 최대 18.3dB, Overall(80Hz~200Hz)값은 18.2dB(A)의 소음저감 효과가 있는 것으로 나타나, 가장 효과적인 부음원과 에러센서간의 거리차인 것으로 평가되었다.

  • PDF

Improvement of Flexural Structural Performance and Applied Section Shape for Sound Proof Wall Structures Using Glass Fiber Reinforced Polymer(GFRP) (GFRP를 활용한 도로 방음벽 구조물의 구조성능 및 단면형상 개선에 관한 연구)

  • Jung, Woo-Young;Choi, Hyun-Kyu
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • This research presents the structural performance and an improving technique for flexural capacity of road safety facilities based on the damage cases by wind pressure. Among road safety facilities, a support frame of soundproofing walls is considered as a prototype structure and its corresponding structural behaviors and section design are performed mainly by analytical and experimental studies. On the basis of analytical results, glass fiber reinforced polymer(GFRP) with an epoxy matrix which is high stiffness-to-weight ratio was used for applied one of strengthening techniques and their results shows that support frame strengthened by GFRP is the most effective compared to other cases proposed in this research for advancing its flexural improvement, Finally, optimum section design was performed analytically to evaluate wind-resistance capacity and its result would be very useful for developing a practical design guideline for Road safety facilities under strong wind.

  • PDF

An Experimental Study on Lateral Load Resistance of a Wall Structure Composed of Precast Concrete and H-Pile (H 파일과 프리캐스트 콘크리트로 형성된 벽체의 횡저항성능에 대한 실험적 연구)

  • Seo, Dong-Joo;Kang, Duk-Man;Lee, Hyun-Gee;Moon, Do-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.9-17
    • /
    • 2020
  • The purpose of this study was to evaluate lateral load resistance of a wall structure composed of precast concrete wall and H-Pile. This type of structure can be used for noise barrier foundation or retaining wall. Mock-up specimens having actual size were designed and fabricated. The lateral design load is 54.6kN. The H-pile length for the test specimen is 1.5m for simulating behavior of actual wall structure has 6.5m H-pile in the field, which is determined from theoretical study. Lateral displacements and strains of wall and H-pile were monitored and cracking in precast concrete wall inspected during the test. Load and deformation capacity of test specimens was compared with design capacity. The comparisons demonstrated that this type of structures, precast concrete wall and H-pile, can resist enough to lateral design load.

A Study on the Characteristic of Railroad Noise and Vibration Propagation (철도소음진동의 전파특성에 관한 연구)

  • 김석홍;이성춘;김준호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.36-41
    • /
    • 1992
  • 철도주변의 쾌적한 생활환경을 유지하기 위해서는 철도차량이나 선로에서 발생하는 공기전파음과 지반을 통하여 전파되는 지반진동을 일정수준 이하 로 제어할 필요가 있으며 이러한 철도 소음진동 대책에는 기존철도에 대한 기초적인 소음진동 크기 및 특성에 대한 자료가 필요하다. 국내에서는 이제 까지 철도소음진동에 대한 특별한 자료수집이나 대책에 큰 관심을 기울여 오지 않고 단지 철로주변에서는 어쩔수 없이 철도소음진동의 피해를 감수할 수 밖에 없다는 소극적인 태도를 취해왔으며 최근에 들어서야 환경의식 증 가로 철로변 거주자들의 민원에 대한 대책으로서 일부 구간에서 방음벽을 설치하고 있는 실정이다. 더우기 경부고속철도 건설이 이미 시작된 현시점에 서 철도 소음진동 실태나 기준등이 정립되어 있지 못하여 추후 철도주변의 소음진동문제를 어떻게 대책을 수립해 나가야 할지에 대한 기본적인 자료수 집 및 관련연구가 필요할 것으로 생각된다. 본 연구에서는 이러한 상황에서 기존 철도의 소음진동 시간 변동특성, 거리감쇠특성, 주파수특성 및 철도진 동의 진동방향 특성을 측정 분석하여 추후 철도소음진동 관련 대책이나 기 준수립에 기초자료로 제시하고자 한다.

  • PDF

A Study on the Development of Sound Absorption Material Using Perlite for Noise Barrier Wall (펄라이트를 이용한 방음벽의 흡음소재 개발에 관한 기초적 연구)

  • Jo, Young-Kug;Yang, Ju-Kyung
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.653-660
    • /
    • 2008
  • The purpose of this study is to analyze the optimal mix design of the sound absorption material that is made from perlite and various binder systems for noise barrier wall. The polymer cement slurry which is made from two types of polymer dispersions, and silicone type inorganic material are used as binder. The test specimens are prepared with various polymer cement ratios, binder ratios, and tested for strengths, freezing and thawing and sound absorption performance by the tube and the reverberation room methods. From the test results, the difference of sound absorption coefficient by the tube method is a little recognized, however, noise reduction coefficient (NRC) of test specimens bound by the polymer cement slurry is in the ranges of 0.48 to 0.51. They are a little higher than those bound by cement only, and are lower values than recommended value of 0.7 by the Ministry of Environment. However, the sound absorption coefficient of test specimens at low frequency range of 250 to 500 Hz by reverberation room method shows very high values as 0.84 to 1.00, and 0.57 to 0.77 at the high frequency. The test specimens with polymer cement slurry binder have a good balance between performance and cost, and have proper properties in strengths, freezing and thawing resistance as sound absorption material for noise barrier wall. It is apparent that the good sound absorption material can be produced according to the optimum mix design that is recommended from this study.

A Study on the Improving Direction of Urban Park Problems by Geographic Information System - Seochogu Yangjae Citizen`s Woods - (GIS를 활용한 도시공원 문제점의 개선방향에 관한 연구 - 서초구 양재 시민의 숲을 중심으로 -)

  • 장동수
    • Spatial Information Research
    • /
    • v.3 no.2
    • /
    • pp.161-177
    • /
    • 1995
  • 본 연구의 목적은 도시공원 조성시 물리.생태적 여건과 이용을 고려해 건강한 도시공원을 조성하는데 기초자료를 제공하는데 있다. 따라서 본 연구는 서울 서초구 양재시민의 숲(공원)을 대상으로 조성된 공원의 물리.생태적 여건과 이용의 관련성을 조사해 나타난 문제들을 GIS와 설문조사를 통해 분석했다. 조사항목으로 과거토지이용, 현토지이용(성토지역, 동선, 나지, 시설물), 식생(수고, 지하고, 최근색재지, 유실수, 불량식재지), 배수상태, 야간조명, 소음, 이용현황(이용밀도, 이용행태, 접근동선) 등이며 수고+소음, 지하고+이용밀도, 과거토지이용+배수불량, 이용행태+접근동선 등을 중첩해 문제점을 분석했다. 그 결과 본 공원은 식재, 배수, 소음, 이용(주차, 야간이용)등의 문제를 앉고 있으며 이에 대한 해결방안으로는 숲내 공지확보, 수로나 연못설치, 방음벽 설치, 주차장 확보 등이다. 설문조사에서 제안된 시설과 대안으로는 공원주변의 양재 화홰단지와 연계한 화단 및 화훼전시공원(43%), 현공원의 잠재력을 활용한 식물원 혹은 수목원(58%), 과일나무 공원(32%) 등을 들 수 있다. 결과적으로 이공원과 같이 규모가 큰 공원을 조성시에 위와 같은 문제들을 해결하기 위해서는 조성기간중 다양한 문제를 수용할 수 있는 유연한 단계별 계획이 필요할 것이다.

  • PDF

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF