• Title/Summary/Keyword: 방어시설

Search Result 237, Processing Time 0.032 seconds

Analysis on the contaminant transport in subsurface soil at Daeduk site (대덕부지 토양내 오염물 이동 해석)

  • Suh, Kyung-Suk;Kim, Eun-Han;Hwang, Won-Tae;Jeong, Hyo-Joon;Han, Moon-Hee;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.155-163
    • /
    • 2003
  • The groundwater flow and contaminant transport numerical models have been established for analyzing the movements of pollutants in subsurface soil at Daeduk site. The groundwater flow and concentration of U-234 using the numerical models were simulated around Daeduk nuclear facilities. The computed groundwater flow was mainly advected toward the direction of east and southeast around HANARO in the site. The radioactive material entered into the subsurface soil was transported along the same direction with groundwater flow. The radioactive material deposited on the surface from the calculated concentration distributions was not affected by surrounding environment of the site.

Dose Determination in the IR-221 Gamma Facility Using a Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 IR-221의 선량 평가)

  • Lim, Ik-Sung;Kim, Ki-Yup;Roh, Gyu-Hong;Lee, Chung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • This study is performed to evaluate the dose rate and to analyze the dose distribution of the gamma irradiation facility (IR-221) by using a Monte Calro simulation, which is helpful of upgrading the radiation processing qualification. Monte Cairo simulation is performed by MCNP4B code. Dose rates were measured at total 369 points with alanine dosimeters to compare the calculation results and the measurements data. The results have shown that the MCNP4B code is very useful to determine the dose distribution of the IR-221 gamma irradiation facility, as the calculation dose rate is within about ${\pm}5%$ of the measurement data. Dosimetry about the gamma irradiation facility usually needs enormous manpower and time. However Monte Cairo calculation method can reduce the tedious dosimetry jobs and improve the irradiation processing qualification, which will probably contribute to obtain the reliability of the irradiation products.

Development of Meteorological Data Acquisition and Meteorological Information Processing System for the Analysis of Radionuclide Behavior in the Atmosphere (방사성물질의 대기중 거동해석을 위한 기상정보인지 및 처리시스템 개발)

  • Kim, Eun-Han;Hwang, Won-Tae;Suh, Kyung-Suk;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.117-122
    • /
    • 1995
  • Meteorological Data Acquisition System (MDAS) and Meteorolocical Information Processing System (MIPS) have been developed for the measurement of the meteorological parameters at the Korea Atomic Energy Research Institute site. MIPS represents the measured meteorological data graphically on a computer screen. MDAS and MIPS are interfaced with real-time radiological dose assessment system (FADAS), which has been developed to rapidly assess the radiological consequences and to support decision-making under radiological emergencies.

  • PDF

Preliminary Analysis of Dose Rate Variation on the Containment Building Wall of Dry Interim Storage Facilities for PWR Spent Nuclear Fuel (경수로 사용후핵연료 건식 중간저장시설의 격납건물 크기에 따른 건물 벽면에서의 방사선량률 추이 예비 분석)

  • Seo, M.H.;Yoon, J.H.;Cha, G.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.189-193
    • /
    • 2013
  • Annual dose on the containment building wall of the interim storage facility at normal condition was calculated to estimate the dose rate transition of the facility of PWR spent nuclear fuel. In this study, source term was generated by ORIGEN-ARP with 4.5 wt% initial enrichment, 45,000 MWd/MTU burnup and 10 years cooling time. Modeling of the storage facility and the containment building and radiation shielding evaluations were conducted by MCNP code depending on the distance between the wall and the facility in the building. In the case of the centralized storage system, the distance required for the annual dose rate limit from 10CFR72 was estimated to be 50 m.

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF

An Historical and Cultural Analysis on the Eastern and Western Moat (동·서양 해자(垓字)의 역사와 문화적 해석)

  • Jung, Yong-Jo;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.105-120
    • /
    • 2011
  • A moat is a pond or waterway paved on the outside of a fortress that is one of the facilities to prevent enemy from approaching the fortress wall or classify it as the boundary space, moats had existed in Europe, Asia and the America from ancient times to medieval times. however it is has been disappeared in modem society. In addition, a moat is a great value in historical and cultural sense such as offering a variety of cultural activities and habitats for animals, but unfortunately there is little consideration of its restoration plan. This research is aimed to investigate historical and cultural meaning and significance of moats which had been existing from ancient times to medieval times in the Eastern and Western. For this purpose, this research analyzed concepts and functions in consideration with times and ideological backgrounds of moats in Korea, China, and Japan. Results were as follows: 1. Moats in Korea existed not only in the castle towns of Goguryeo but also in ancient castle towns of Baekje and Silla. Natural moats and artificial moats existed around castles that were built to prevent and disconnect accessibility of enemies In Goryeo Dynasty and Chosun Dynasty, moats were also used as a defensive function. 2. A moat was generally installed by digging in the ground deep and wide at regular intervals from the ramparts, A moat was installed not only around a castle but also in its interiors. Moats outside castles played an important role in stomping the ground hard besides enhancing its defensive power. In addition, water bodies around a facility often discouraged people's access and walls or fences segregated space physically, but a moat with its open space had an alert and defensive means while pertaining its visual characteristics. 3. The moat found at Nagan Eupseong rumor has it that a village officials' strength was extremely tough due to strong energy of the blue dragon[Dongcheon] in Pungsujiri aspects, so such worries could be eliminated by letting the stream of the blue dragon flow in the form of 'S'. 4. The rampart of the Forbidden City of China is 7.9 meters high, and 3,428 meters long in circumference. It was built with 15 layers of bricks which were tamped down after being mixed with glutinous rice and earth, so it is really solid. The moat of the Forbidden City is 52 meters in width and 6 meters in depth, which surrounds the rampart of the Forbidden City, possibly blocking off enemies' approach. 5. Japan moats functioned as waterways due to their location in cities, further, with the arrangement of leisure facilities nearby, such as boating, fishing from boats, and restaurants, it helped relieve city dwellers' stress and functions as a lively city space. 6. Korean moats are smaller in scale than those of the Forbidden City of China, and Edo, and Osaka castles in Japan, Moats were mostly installed to protect royal palaces or castles in the Eastern Asia whereas moats were installed to protect kings, lords, or properties of wealthy people in the west.

Cyber attack group classification based on MITRE ATT&CK model (MITRE ATT&CK 모델을 이용한 사이버 공격 그룹 분류)

  • Choi, Chang-hee;Shin, Chan-ho;Shin, Sung-uk
    • Journal of Internet Computing and Services
    • /
    • v.23 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • As the information and communication environment develops, the environment of military facilities is also development remarkably. In proportion to this, cyber threats are also increasing, and in particular, APT attacks, which are difficult to prevent with existing signature-based cyber defense systems, are frequently targeting military and national infrastructure. It is important to identify attack groups for appropriate response, but it is very difficult to identify them due to the nature of cyber attacks conducted in secret using methods such as anti-forensics. In the past, after an attack was detected, a security expert had to perform high-level analysis for a long time based on the large amount of evidence collected to get a clue about the attack group. To solve this problem, in this paper, we proposed an automation technique that can classify an attack group within a short time after detection. In case of APT attacks, compared to general cyber attacks, the number of attacks is small, there is not much known data, and it is designed to bypass signature-based cyber defense techniques. As an attack model, we used MITRE ATT&CK® which modeled many parts of cyber attacks. We design an impact score considering the versatility of the attack techniques and proposed a group similarity score based on this. Experimental results show that the proposed method classified the attack group with a 72.62% probability based on Top-5 accuracy.

A Study on Seepage Control of Levee with Pervious Toe Drain (본배수공을 이용한 하천제방의 침윤조절에 관한 연구)

  • Lee, Sang-Ho;Kong, Young-San;Lee, Nam-Joo;Yu, Kwon-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.162-166
    • /
    • 2011
  • 하천제방은 가장 치수효과가 높은 홍수방어시설로서 홍수 시 유수를 원활하게 소통시키고 제내지를 보호하기 위해 하천을 따라 축조한 시설이다. 누수에 의한 제방파괴는 제내지 제체에 드러난 포화표면이 결정적인 요인이 되므로 침윤선을 낮추어 제체하부에 위치하도록 해야 하며 누수가 발생한 제방에 대해서는 적절한 보강기법을 적용해야 한다. 본 연구에서는 하천제방 축조 또는 보강 시 누수에 의한 파괴를 방지하기 위한 방법으로 미국 공병단과 일본 국토기술연구센터에서 사용하는 기법 중 하나인 배수공을 두어 침윤선을 조절하는 방법을 적용하였다. 구체적으로 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 가지는 경우의 제방 실험 및 수치 모형 보정 결과를 비교하였다. 침투 수치 모의는 SEEP/W 프로그램으로 검토하였다. 실험에 적용한 제방의 규격은 제방폭 2.6 m, 둑마루폭 0.4 m, 사면경사 1:2, 제방 높이 0.55 m, 수위 0.5 m이다. 배수공이 없는 제방은 사면에서 누수가 발생하였으며, 배수공 바닥폭이 0.4 m인 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 설치하였을 때는 누수가 발생하지 않았다. 같은 배수공 바닥폭을 가지는 공병단과 일본 국토기술연구센터식 배수공을 설치한 제방의 실험을 비교한 결과, 일본국토기술연구센터식 배수공을 설치한 제방의 침윤선이 공병단식 배수공을 설치한 제방보다 낮았다. 즉, 일본 국토기술연구센터식 사각형 배수공이 다소 안정한 것으로 분석되었다.

  • PDF

An Analysis of Runoff reduction Amounts for the Detention Pond in Trunk Sewer (간선저류지 설치위치에 따른 우수유출저감효과 분석)

  • Lee, Sung Ho;Lee, Jae Joon;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.556-556
    • /
    • 2016
  • 도시화 및 산업화에 따른 유출량의 증가 및 도달시간의 감소로 인해 도시지역의 침수피해가 빈번하게 발생되고 있는 실정이다. 내수침수피해 방지를 위해 유역내 우수관거 용량향상 및 우수유 출저감시설의 설치 등과 같은 유역전반의 홍수방어 체계를 구축하고자 하는 노력들이 이루어지고 있으나, 국내 대도시의 경우 저류시설 설치를 위한 부지 확보 및 우수관거 교체를 위한 예산확보가 어려운 실정이다. 따라서 도시화, 산업화, 인구집중으로 동일규모의 강우에서도 우수유출이 증대되고 있는 도시지역에서 원활한 내수배제를 위해 우수관거를 연계한 간선저류지 개념을 적용하여 우수유출저감효과를 분석할 필요가 있다. 본 연구에서는 간선저류지를 유역내의 임의의 위치에 설치하여 단일 저류지와 복수 저류지에 대해 각각 우수유출저감효과를 분석하였다. 간선저류지 설치로 인한 우수유출저감효과 분석을 위하여 단일 저류지의 면적은 $1,000m^3$, $2,000m^3$, $3,000m^3$ 등 3가지 크기로 설정하여 분석을 수행하였다. 단일 저류지의 위치에 따른 유출저감효과를 분석하기 위해 저류지의 위치는 전체 유역면적에 대한 저류지 상류부 면적의 비를 20%, 40%, 60%, 80%로 변화시키면서 분석을 수행하였으며, 복수 저류지의 경우 전체 유역면적에 대한 저류지 상류부 면적의 비를 다양하게 적용하여 분석을 수행하여, 단일 저류지 및 복수 저류지 설치 위치에 따른 도시유역의 우수유출저감효과를 분석하였다.

  • PDF