• Title/Summary/Keyword: 방사형 필터

Search Result 19, Processing Time 0.021 seconds

Emission-Notch Filter Fusion design for serially sectioned human image improvement (인체연속절단면 영상 개선을 위한 방사형-놋치필터 융합 설계)

  • Cho, Do Hee;Park, Hyung-Ju;Har, Dong-Hwan
    • Korea Science and Art Forum
    • /
    • v.25
    • /
    • pp.379-388
    • /
    • 2016
  • There are some studies to get rid of slice patterns in coronal and sagittal images by FFT(Fast Fourier Transform) and Notch filter. However, the use of a notch filter is the ringing effect according to the rapid frequency change occurs in common. Therefore, this study will be to evaluate the shape and effect of the notch filter. In addition, it is proposed a new notch filter design. Results of the study are as follows. First, Emission-Notch filter was relatively naturally correcting the cutting pattern. Second, Emission-Notch filter to use as Ringing effect is reduced relatively. The next through these findings and further research progress more completely removed the Ringing effect, and expects to reproduce the data close to the actual human body information.

Current Status of the Spent Filter Waste and Consideration of Its Treatment Method in KAERI (KAERI 저장 폐필터의 현황과 처리방법에 관한 고찰)

  • Ji, Young-Yong;Hong, Dae-Seok;Kang, Il-Sik;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.257-265
    • /
    • 2007
  • Spent filter wastes of about 1,000 units (200 L) have been stored in the waste storage facility of the Korea Atomic Energy Research Institute since its operation. At the moment, to secure space in a waste storage facility as well as to efficiently manage spent filter wastes, it is necessary to conduct a compaction treatment of these spent filters, and finally, to repack the compacted spent filters into a 200 liter drum. To do that, the spent filter wastes were first classified according to their generation facilities, their generation date and their surface dose rate by investigating the inventory of the spent filters. In order to repack a compacted spent filter in a 200 liter drum, it is first necessary to conduct a radionuclide assessment of a spent filter before compacting it. Therefore, after taking a representative sample from a spent filter without a dismantlement, the nuclide analysis for it will be conducted. And then, after putting a spent filter into a regular drum by conducting the columnar shaping of the hexahedral form of a spent filter, the compaction treatment of the shaped spent filter will be conducted by vertically compacting it.

  • PDF

A Study on the Removal Method of Radioactive Corrosion Product using its Magnetic Property (방사성 부식생성물의 자기적 성질을 이용한 제거방법에 대한 연구)

  • 송민철;공태영;이건재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.73-79
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power Plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having m effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is performed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUB.

  • PDF

Pre-equalization Method to reduce delay time in Equalization Digital On-Channel Repeater for ATSC Terrestrial DTV System (등화형 동일채널 중계기를 위한 시간지연 최소화 전치등화 방법)

  • Kim, Heung-Mook;Park, Sung-Ik;Seo, Jae-Hyun;Eum, Ho-Min;Lee, Yong-Tae;Kim, Seung-Won
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.77-80
    • /
    • 2005
  • 본 논문에서는 ATSC 지상파 디지털 TV 방송방식을 사용하는 등화형 동일채널 중계기(Equalization Digital On-Channel Repeater: EDOCR)에서의 신호처리 시간지연을 최소화하기 위한 전치등화 방법에 대하여 기술하고 결과를 다양한 각도에서 분석한다. 제안된 전치등화 방법은 기준신호인 기저대역 신호와 복조된 중계기 출력신호를 이용하여 전치등화필터계수를 계산하고 펄스성형필터계수와의 컨볼루션을 통해 얻어진 새로운 펄스성형필터를 이용하는 것이다. 새로운 펄스성형필터의 전치 탭 수를 조절함으로써 시간지연을 최소화하고, 마스크필터에 의한 선형왜곡을 보상할 뿐 아니라, 원래 펄스성형필터의 대역 외 방사 특성의 열화를 최소화할 수 있다. 이를 컴퓨터 시뮬레이션 및 제작된 전치등화기를 이용하여 검증하였다.

  • PDF

Conceptual Design of the Filter using Electromagnet and Permanent Magnets for Removal of Radioactive Corrosion Products (방사성 부식생성물 제거를 위한 전자석 및 영구자석을 이용한 필터의 개념설계)

  • 송민철;공태영;이건재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.38-42
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having an effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is peformed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUD.

  • PDF

Detection of Mass Type Breast Tumor Using Spiculate Filter (방사형 필터를 이용한 Mass형 유방암 검출)

  • Park, Jun-Young;John, Min-Su;Kim, Won-Ha;Kim, Sung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.367-369
    • /
    • 2005
  • In this paper, we present a new method for the detection of spiculation on digital mammograms. Traditional methods have defects; sensitive to noise, fixed size processing, and long processing time, however, the proposed method has merits; not sensitive to noise, adaptive size processing, and fast processing time. Experimental results show that the spiculation detection performance of the proposed method is improved much compared to the other methods.

  • PDF

Automatic detection of mass type - Breast cancer on dense mammographic images (치밀 유방영상에서 mass형 유방암 자동 검출)

  • Chon Min-Su;Park Jun-Young;Kim Won-Ha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.5 s.311
    • /
    • pp.80-88
    • /
    • 2006
  • In this paper we developed a novel system for automatic detection of mass type breast cancer on dense digital mammogram images. The new approaches presented in this paper are as follows: 1) we presented a method that stably decides the mass center and radius without being affected by image signal irregularity. 2) We developed a radial directional filter that is suitable to process mass image signal. 3) And we developed the multiple feature function based on mass shape spiculation, mass center homogeneity, and mass eccentricity, so as to determine mass-type breast cancer. When the proposed system is applied to dense mammographic images, the true 기arm rate is improved by 10% over a conventional system while the false alarm is increased by 1 per image.

Image processing in a discrete polar coordinate system based on L1-norm (L1-norm 기반 이산 극좌표에서의 영상처리)

  • John, Min-Su;Lee, Nam-Koo;Kim, Won-Ha;Kim, Sung-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.20-28
    • /
    • 2008
  • We propose a radial image processing method in a discrete polar coordinate system based on L1-norm. For this purpose, we first verified that the polar coordinate based on L2-norm can not exist in discrete system and then develop a method converting the Cartesian coordinate to the discrete polar coordinate. We apply the proposed method to smooth mass images of breast tissue and to detect the boundaries of extremely deformable objects. Compared to the Gaussian smoothing method performed in the Cartesian coordinate system, the proposed method stabilized the image signal while maintaining the overall radial shape of mass images. The proposed boundary detection method can detect shapes with high precision while conventional edge detectors can not accurately detect the shape of deformable objects. We also exploit the method to perform pupil detection and have had good experimental results.

A Study on Dry and Wet Wipe Test for Radioisotope Leakage Checking (방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법 연구)

  • Park, SangMin;Yoo, SeungHee;Choi, KyuSeok;Lee, HwaHyung;Hong, Sayong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.305-312
    • /
    • 2018
  • A dry and wet wipe test for radioisotope leakage checking was conducted by fixing the radioisotope $^{14}C$ to the glass surface and used for observing the transfer factor and surface shape of the test paper through wipe test. The dry wipe test showed that transfer factor in the tissue paper was twice as high as in the paper filter, and the wet wipe test showed that transfer factor in the paper filter paper was three times higher than the tissue paper. Although paper filters are general choice for leakage checking, it has been shown that tissue paper can be an alternative in the dry wipe test.

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF