• Title/Summary/Keyword: 방사조사

Search Result 1,887, Processing Time 0.027 seconds

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

Ultrasensitive Enzymeimmunoassay for Testosterone in Human Saliva (사람 타액내 Testosterone의 초감도 효소면역측정법)

  • 윤용달;전은현;이창주;도병록;이준영
    • Development and Reproduction
    • /
    • v.4 no.1
    • /
    • pp.115-123
    • /
    • 2000
  • A few enzymeimmunoassay (EfA) for testosterone (T) have been reported but was not suitable for all biological samples. The present study was designed to develop a rapid, ultrasensitive EIA and to apply this technique for study the physiological changes of T in biological samples. Saliva samples were collected at 06:00~09:00 hour during one menstrual cycle from 18 normally menstruating women and on 09:00~10:00 hour from 20 normal men. The present study shows an established EIA for testosterone, using horseradish peroxidase (HRP), which was covalently bonded to testosterone-3-carboxymethyloxime (T-3-CMO). One batch of T-antisera was also covalently linked to microcrystalline cellulose particles by a mixed anhydride method in order to facilitate separation of bound and free steroids. The established EIA was validated in terms of sensitivity, accuracy, specificity, precisions etc., comparing with conventional radioimmunoassay. The sensitivity of the established EIA was less than 25 pg/tube. The correlation coefficients between the expected T-values and observed T-values measured by EIA or RIA were r=0.985 and r=0.941 respectively. The cross reactivity of antiserum in EIA was a little higher than that of RIA, especially by 5 ${\alpha}$-DHT. The intra- and inter-assay precisions of the present EIA were similar to those of RIA. The present study also demonstrates that the normal T-values in saliva of Korean male & female samples are 265.65${\pm}$15.80 pmol/l and 109.74${\pm}$ 12.01 pmol/l, respectively. The present EIA seems to be established and suitable for use in the endocrinological studies. The advantages of this EIA system also might make the present T-EIA an ideal procedure for use in a routine assay of ordinary laboratory with a conventional spectrophotometer.

  • PDF

The Uptake of $Cs^{137}$ Paddy Rice from Soil and its Distribution in the Plant (답토양(畓土壤)에서 수도(水稻)의 Cesium-137 흡수(吸收)와 수도체내(水稻體內) 분포(分布))

  • Kim, Jae-Sung;Lim, Soo-Kil
    • Korean Journal of Environmental Agriculture
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 1985
  • A pot experiment was conducted to study the influence of potassium and cesium carrier on the uptake of radionuclide $Cs^{137}$ which is an element released usually from nuclear facilities, by paddy rice upon prolonged cropping of contaminated soils. The results are summarized as follows: 1) Visual toxic symptoms on the growth of rice plant due to treatment of radioactive cesium were not observed up to $20 {\mu}Ci/10Kg$ soil in a pot. 2) The yield and potassium content in rice plant were increased with potassium application, while the reverse was true for the calcium and magnesium. The addition of potassium to the soil markedly reduced $Cs^{137}$ uptake by rice plant but the addition of Cs carrier increased $Cs^{137}$ uptake. 3) Potassium and $Cs^{137}$ showed uniform distribution in all parts of plant and the contents of these two elements were high in the stems and leaves, and low in the heads. The ratio of $Cs^{137}$ to K was, however, not uniform in all parts of a plant. It was shown that this ratio was higher in the seed part, that is, chaff and hulled grain than in the leaves and stems. 4) $Cs^{137}$ absorption rate in rice plant was remarkably reduced with increase of potassium application and it was ranged from $0.02{\sim}0.47%$ in potassium non-treated plot to 0.01∼0.04% in plot treated with a concentration of 16Kg/10a. 5) The amount of $Cs^{137}$ and potassium uptake of rice plant depended on soil type. Uptake of $Cs^{137}$ by rice plant was higher in the soil with low pH and potassium content. The $Cs^{137}$ uptake by rice plant decreased as the potassium content and pH of soil was increased, but $Cs^{137}$ uptake increased when CEC and clay content in soil was high.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Paclitaxel and Cisplatin with Induction Chemotherapy Followed by Concurrent Chemoradiotherapy for Stage IIIB Non-small Cell Lung Cancer (IIIB 병기 비소세포폐암에서 Paclitaxel과 Cisplatin을 이용한 선행항암화학요법과 동시 항암화학방사선치료)

  • Kang, Ki-Mun;Lee, Gyeong-Won;Kang, Jung-Hoon;Kim, Hoon-Gu;Lee, Won-Seob;Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.223-229
    • /
    • 2006
  • $\underline{Purpose}$: Combined modality therapy including chemotherapy, surgery and radiotherapy is considered the standard of care for the treatment of stage III non-small cell lung cancer (NSCLC). This study was conducted to evaluate the efficacy of paclitaxel and cisplatin with induction chemotherapy followed by concurrent chemoradiotherapy for stage IIIB NSCLC. $\underline{Materials\;and\;Methods}$: Between July 2000 and October 2005, thirty-nine patients with stage IIIB NSCLC were treated with two cycles of induction chemotherapy followed by concurrent chemoradiotherapy. The induction chemotherapy included the administration of paclitaxel ($175\;mg/m^2$) by intravenous infusion on day 1 and treatment with cisplatin ($75\;mg/m^2$) by intravenous infusion on day 1 every 3 weeks. Concurrent chemoradiotherapy included the use of paclitaxel ($60\;mg/m^2$) plus cisplatin ($25\;mg/m^2$) given intravenously for 6 weeks on day 43, 50, 57, 71, 78 and 85. Thoracic radiotherapy was delivered with 1.8 Gy daily fractions to a total dose of $54{\sim}59.4\;Gy$ in $6{\sim}7$ weeks (median: 59.4 Gy). $\underline{Results}$: The follow up period was $6{\sim}63$ months (median: 21 months). After the induction of chemotherapy, 41.0% (16 patients) showed a partial response and 59.0% (23 patients) had stable disease. After concurrent chemoradiotherapy, 10.3% (4 patients) had a complete response, 41.0% (16 patients) had a partial response, and the overall response rate was 51.3% (20 patients). The 1-, 2-, 3-year overall survival rates were 66.7%, 40.6%, and 27.4% respectively, with a median survival time of 20 months. The 1-, 2-, 3-year progression free survival rates were 43.6%, 24.6%, and 24.6%, respectively, with median progression free survival time of 10.7 months. Induction chemotherapy was well tolerated. Among 39 patients who completed the entire treatment including chemoradiotherapy, 46.3% (18 patients) had esophagitis greater than grade 3 and 28.2% (11 patients) had radiation pneumonitis greater than grade 3. $\underline{Conclusion}$: Paclitaxel and cisplatin with induction chemotherapy followed by concurrent chemoradiotherapy for stage IIIB NSCLC seems to be an effective treatment. Occurrence of esophagitis and pneumonitis represents a significant morbidity and suggests a modification of the treatment regimen, either with the chemotherapy schedule or with radiotherapy treatment planning.

The Study of CYFRA 21-1 and Epidermal Growth Factor Receptor Levels in Cancer Tissue of Bronchogenic Carcinoma Patients (폐암환자의 암조직내 CYFRA 21-1과 Epidermal Growth Factor Receptor의 측정치에 대한 연구)

  • 김대연;김송명
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.854-861
    • /
    • 1997
  • CYPRA 21-1 is known to be a cytokeratin 19 fragment, and it can be detected by using two specific monoclonal antibodies (KS 19-1 and BM 19-21) and can be clinically applied as a useful circulating tumor marker The epidermal growth factor receptor (EGF-R) expression was evaluated and characterized by its tyrosine protein kinase activity and by its ligand-stimulated autophosphorylation, a property shared with other peptide growth factor receptors. Autocrine or para'urine action was initiated by a growth factor, or by a transforming growth factor o, which had an extensive homology with EGP and which also stimulated tyrosine kinase activity on the EGF-R. The CYFRA 21-1 and the EGF-R levels in 30 patients with primary lung tumors were investigated. There were 24 patients with squamous cell carcinomas and 6 patients with adenocarcinomas. Specimen 5 mm3 in size were sampled at three different locations ; the main lesion, the boundary between the lesion and the unaffected tissue, and the unaffected tissue of the patients. The results were as follows 1. The CYPRA 21-1 concentration in the cancer boundary, the most malignant region,(348.6 : 89.9 ng/ml) was the lowest value. The CYFRA 21-1 concentration in unaffected tissue,(718.4$\pm$77.8 ng/ml) was higher than that in the main lesion. which had intact cellularity. 2. The EGF-R concentration in the main lesion was higher than that in the unaffected tissue, and the EGF-R concentration in a squamous cell cacinoma was higher than that in an adenocarcinoma. also, the EGF-R concentration in the cancer b undary was highest at stage 1, ll. The EGF-R concentration was higher in the main cancer lesion that in the unaffected tissue at stage 111, IV. 3. The CYFRA 21-1 was a cytoplasmic skeleton and the EGF-R was a cell-wall component; there was no correlation. In conclusion, CYFRA 21-1 was abundant in the cytoplasm but had a higher concentration in the unaffected tissue than in the main cancer lesion. The CYFRA 21-1 concentration of the tissue did not reflect the amount of cancer activity, the EGP-R was located in the cell membrane, the level of tissue that reflects cancer activity, so the main cancer lesion had a higher concentration than the unaffected tissue. CYFRA 21-1 is not a useful tumor maker at the tissue level. Because the EGF-R concentration re(looted the cancer activity, its a useful tumor marker for lung cancer.

  • PDF

Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy (Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.155-162
    • /
    • 1998
  • Ho-l66 was produced by neutron reaction in a reactor at the Korea Atomic Energy Institute (Taejon, Korea). Ho-l66 emits a high energy beta particles with a maximum energy of 1.85 MeV and small proportion of gamma rays (80 keV). Therefore, the radiation absorbed dose estimation could be based on the in-vivo quantification of the activity in tumors from the gamma camera images. Approximately 1 mCi of Ho-l66 in solution was mixed into the flood phantom and planar scintigraphic images were acquired with and without patient interposed between the phantom and scintillation camera. Transmission factor over an area of interest was calculated from the ratio of counts in selected regions of the two images described above. A dual-head gamma camera(Multispect2, Siemens, Hoffman Estates, IL, USA) equipped with medium energy collimators was utilized for imaging(80 keV${\pm}$10%). Fifty-nine year old female patient with hepatoma was enrolled into the therapeutic protocol after the informed consent obtained. Thirty millicuries(110MBq) of Ho-166-CHICO was injected into the right hepatic arterial branch supplying hepatoma. When the injection was completed, anterior and posterior scintigraphic views of the chest and pelvic regions were obtained for 3 successive days. Regions of interest (ROIs) were drawn over the organs in both the anterior and posterior views. The activity in those ROIs was estimated from geometric mean, calibration factor and transmission factors. Absorbed dose was calculated using the Marinelli formula and Medical Internal Radiation Dose (MIRD) schema. Tumor dose of the patient treated with 1110 MBq(30 mCi) Ho-l66 was calculated to be 179.7 Gy. Dose distribution to normal liver, spleen, lung and bone was 9.1, 10.3, 3.9, 5.0 % of the tumor dose respectively. In conclusion, tumor dose and absorbed dose to surrounding structures were calculated by daily external imaging after the Ho-l66 therapy for hepatoma. In order to limit the thresholding dose to each surrounding organ, absorbed dose calculation provides useful information.

  • PDF

Changes on physio-chemical properties of oak sawdust during fermentation (참나무류 톱밥의 발효기간 중 물리화학적 특성 변화)

  • Koo, Chang-Duck;Lee, Sun-Jeong;Lee, Hwa-Yong;Park, Yong-Woo;Lee, Hee-Su;Kim, Je-Su
    • Journal of Mushroom
    • /
    • v.12 no.3
    • /
    • pp.209-215
    • /
    • 2014
  • Changes in physical and chemical properties of oak sawdust were investigated by depth and time for 46 days during the fermentation process of 33 tons of the sawdust for oak mushroom cultivation. The degrees of change in the properties of the sawdust differed depending on the depth and fermentation period. Most of the physical-chemical properties except temperature and pH gradually changed during the fermentation. The temperature change was highly sensitive to the environment at the surface sawdust to 20 cm depth, while it gradually increased to the maximum $58.9^{\circ}C$ at 40~100 cm depths in 12 days and slowly to the maximum at 150 cm depth in 24 days. The moisture content of the sawdust decreased gradually from 31% to 26.5~28.0% in 24 days. Of the chemical properties during the fermentation, pH generally rose from 5.2 to 5.6, but it decreased to 4.4~4.7 at 150 cm depth in 16 days. While the carbon content of the sawdust was 68~70% without significant change, nitrogen content increased from 0.22% to 0.25% and thus C/N ratio gradually lowered from 320 to 280. P content in the sawdust gradually increased from 0.005% to 0.022% for 46 days. Osmotic concentration of the hot water extract of the sawdust varied 41.5~44.2 mmol/kg without significant change by the depth and time. The starch particles within initial ray parenchyma cells of sawdust decreased and fungal hyphae formed on the surface of the sawdust granules and within xylem vessel cells in 35 days. The effect of the sawdust fermentation on oak mushroom cultivation needs continued research.

Study of Mobility for Radionuclides in Nuclear Facility Sites (원자력 시설물 주변에서의 방사성 오염물 거동 특성 연구)

  • Chang, Seeun;Park, JongKul;Um, Wooyong
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.99-111
    • /
    • 2018
  • In this study three target radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) were reacted with solid samples collected from the nuclear facility sites to investigate their sorption and mobility behaviors for preparing unexpected nuclear accidents. The highest sorption distribution coefficients ($K_{ds}$) of target radionuclides ($^{60}Co=947mL/g$, $^{137}Cs=2105mL/g$, $^{125}Sb=81.3mL/g$) were found in topsoil layer under groundwater condition, and the $K_d$ values of three radionuclides decreased in the order of fractured rock and bedrock samples under the same groundwater condition. High $K_d$ values of $^{60}Co$ in topsoil layer and fracture rock resulted from the clay minerals present, and the $K_d$ values decreased 58-69 % under seawater condition due to high ionic strength. $^{137}Cs$ sorption was controlled by the ion exchange reaction with $K^+$ on flayed edge sites (FES) of mica. The $^{137}Cs$ sorption was the most affected by seawater (89-97 % decrease), while $^{125}Sb$ sorption was not much affected by seawater. As the results of column and batch experiments, the retardation factors (R) of $^{137}Cs$, $^{60}Co$, and $^{125}Sb$ were determined about 5400-7400, 2000-2500, and 250-415, respectively, indicating no significant transport for these radionuclides even in fractured zone with groundwater. These results suggest that even in the case of severe nuclear accident at the nuclear facilities the mobility of released radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) can be significantly retarded by the topsoil layer and fractured rock. In addition, the results of this study will be used for the safety and environmental performance assessment of nuclear facilities.