• Title/Summary/Keyword: 방사조건

Search Result 1,107, Processing Time 0.035 seconds

A Study on the Heat Flow Analysis of Infra-Red Signature Suppression System for Naval Ship (함정 적외선 신호저감 장치의 열 유동해석 연구)

  • Yoon, Seok-Tae;Cho, Yong-Jin;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.740-746
    • /
    • 2017
  • Infrared signatures emitted from hot exhaust gases generated by the internal combustion engine and generator of naval ships and from the metal surfaces of the funnel have become the targets of infrared homing missiles, which is the main cause of a reduced survivability of naval ships. The infrared signatures from the exhaust gas and the metal surface of a funnel can be reduced by installing an infrared signature suppression (IRSS) system on a ship. The IRSS system consists of three parts: an eductor that generates turbulent flow of the exhaust gas, a mixing tube that mixes the exhaust gas with ambient air, and a diffuser that forms an air film using the pressure difference between the inside and outside air. As a basic study to develop an IRSS system using domestic technology, this study analyzed the model test conditions of an IRSS system developed by an overseas engineering company and installed on a domestic naval ship, and a numerical heat-flow analysis was conducted based on the results of the aforementioned analysis. Numerical heat-flow analysis was performed using a commercial numerical-analysis application, and various turbulence models were considered. As a result, the temperature and velocity of the exhaust gas at the educator inlet and diffuser outlet and that of the metal surface of the diffuser were measured, and found to agree well with the measurement results of the model test.

On the Solution Method for the Non-uniqueness Problem in Using the Time-domain Acoustic Boundary Element Method (시간 영역 음향 경계요소법에서의 비유일성 문제 해결을 위한 방법에 관하여)

  • Jang, Hae-Won;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.19-28
    • /
    • 2012
  • The time-domain solution from the Kirchhoff integral equation for an exterior problem is not unique at certain eigen-frequencies associated with the fictitious internal modes as happening in frequency-domain analysis. One of the solution methods is the CHIEF (Combined Helmholtz Integral Equation Formulation) approach, which is based on employing additional zero-pressure constraints at some interior points inside the body. Although this method has been widely used in frequency-domain boundary element method due to its simplicity, it was not used in time-domain analysis. In this work, the CHIEF approach is formulated appropriately for time-domain acoustic boundary element method by constraining the unknown surface pressure distribution at the current time, which was obtained by setting the pressure at the interior point to be zero considering the shortest retarded time between boundary nodes and interior point. Sound radiation of a pulsating sphere was used as a test example. By applying the CHIEF method, the low-order fictitious modes could be damped down satisfactorily, thus solving the non-uniqueness problem. However, it was observed that the instability due to high-order fictitious modes, which were beyond the effective frequency, was increased.

Feature Vector Extraction and Classification Performance Comparison According to Various Settings of Classifiers for Fault Detection and Classification of Induction Motor (유도 전동기의 고장 검출 및 분류를 위한 특징 벡터 추출과 분류기의 다양한 설정에 따른 분류 성능 비교)

  • Kang, Myeong-Su;Nguyen, Thu-Ngoc;Kim, Yong-Min;Kim, Cheol-Hong;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.446-460
    • /
    • 2011
  • The use of induction motors has been recently increasing with automation in aeronautical and automotive industries, and it playes a significant role. This has motivated that many researchers have studied on developing fault detection and classification systems of an induction motor in order to minimize economical damage caused by its fault. With this reason, this paper proposed feature vector extraction methods based on STE (short-time energy)+SVD (singular value decomposition) and DCT (discrete cosine transform)+SVD techniques to early detect and diagnose faults of induction motors, and classified faults of an induction motor into different types of them by using extracted features as inputs of BPNN (back propagation neural network) and multi-layer SVM (support vector machine). When BPNN and multi-lay SVM are used as classifiers for fault classification, there are many settings that affect classification performance: the number of input layers, the number of hidden layers and learning algorithms for BPNN, and standard deviation values of Gaussian radial basis function for multi-layer SVM. Therefore, this paper quantitatively simulated to find appropriate settings for those classifiers yielding higher classification performance than others.

Manufacture and Properties of White Charcoal Board in Relation with Final Mat Moisture Content and Charcoal Particle Size (백탄파티클 크기와 최종매트함수율에 따른 백탄보드의 제조와 성능)

  • Lee, Hwa Hyoung;Cho, Youn Mean;Park, Han Sang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.3 s.131
    • /
    • pp.22-29
    • /
    • 2005
  • This research was carried out not only to examine the proper manufacturing condition for white charcoal board in relation to charcoal particle size and final mat moisture content (FMC), but also to maintain the advantageous properties of white charcoal as a well being building material against the sick house problem. Excellent functional white charcoal board was produced with two groups of FMC 20~25% and FMC 36~60%. The latter showed best results among tested samples in two types which are #40-60type-P15%, M5%, FMC 60% and mixed type-P15%, M5%, FMC36% with non formaldehyde adhesives [MDI (M), poly vinyl acetate emulsion (P)] and three stage pressing cycle of 30-10-$30kgf/cm^2$ (1 min.-1.5 min.-6 min.). The former gave highly acceptable results in two types which are #6 over-M15%FMC25% and mixed type-M25%FMC20%. White charcoal board gave excellent in dimensional stability, gas adsorption and far-infrared emission.

Anatomy of Quercus variabilis Charcoal Manufactured at Various Temperatures (제조 온도에 따른 굴참나무 목탄의 해부학적 특성)

  • Kim, Nam-Hun;Hwang, Won-Joong;Kwon, Sung-Min;Kwon, Goo-Joong;Lee, Seong-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1-8
    • /
    • 2006
  • Anatomy of Quercus variabilis charcoal was investigated by scanning electron microscopy. Charcoal was prepared in an electric furnace under nitrogen gas atmosphere at $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$, and $1000^{\circ}C$ for 10 min. The structure of charcoal was significantly affected by charring temperature. In cross section, charcoal prepared at $400^{\circ}C$ exhibited a smooth clean surface. As the charring temperature increased, the surface became more rough and increasingly disrupted. The cell walls appeared homogeneous and glass-like. Ray parenchyma cells showed very little separation from each other in radial section at $400^{\circ}C$. At $600^{\circ}C$ and above there is an apparent disintegration of the middle lamella, resulting in a separation of the ray cells. The $2{\sim}4{\mu}m$ wart-like protuberances were observed on the surfaces of the parenchyma cells. These structures were seen in charcoal prepared at all temperatures. Distinctive features can be seen in multiseriate rays as large crack and split. Rhomboidal crystals in crystalliferous cells had a smooth surface at $400^{\circ}C$ and $600^{\circ}C$, but the crystals had a sponge like appearance at $800^{\circ}C$ and $1000^{\circ}C$.

Leveling the Gamma-ray Spectrometric Data using Baseline Survey (Baseline 탐사를 이용한 항공 방사능 탐사 자료 맞추기)

  • Park, Yeong-Sue;Rim, Hyoungrea;Lim, Mutaek;Shin, Young Hong
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.97-104
    • /
    • 2015
  • KIGAM has surveyed most of the Korean territory since 1982 using airborne gamma-ray spectrometry, and complete the nationwide scale map in the near future. However, since the duration of survey is too long and the conditions of survey is not consistent, the data does not have physical consistency. In addition, the window counts (count/sec) were recorded instead of potassium, uranium and thorium radioelement concentrations. Thus, the data could not be registered to the International Atomic Energy Agency (IAEA) radioelement datum. This limits the usefulness of the data and it is not possible to easily combine surveys into regional compilations or make quantitative interpretations between different survey areas. To solve these problems, we undertook a test baseline survey over Jincheon-Eumseong area, to level the different two sets of data and to map radioelement concentrations. This survey confirms to IAEA radioelement baseline. The method and procedures of data leveling prepared by this study improve the usefulness and usability of the radiometric data, and make it enable to compile the nationwide scale radioelement concentration maps.

Development by Temperatures and Copulation Flight of Comstock mealybug, Pseudococcus comstocki (가루깍지벌레(Pseudococcus comstocki )의 온도별 발육 및 교미비행)

  • Cho, Min-Kyu;Kwon, Hey Ri;Yu, Yong Man;Youn, Young Nam
    • Korean journal of applied entomology
    • /
    • v.57 no.2
    • /
    • pp.105-115
    • /
    • 2018
  • The comstock mealybug is one of the serious insect pest in pear. It is necessary effective control methods such as attractive sex pheromone. Using sex pheromones is necessary for studying the physiology and ecology of insect pests. In the present study, the sex pheromone of comstock mealybug was used for investigating the flying acts of the adult male. As temperature increased, the development period of eggs shortened, but it was longer at $30^{\circ}C$. The mean number of eggs laid was 482 at $25^{\circ}C$ and males constituted 37% of the experimental population at $30^{\circ}C$. The flight of the male comstock mealybug was mostly restricted to a 2-4 hour period after sunrise, even if condition of light period is changed. Male mealybugs were incapable of upwind flight towards an attractant when air velocity was 1.5 mph. Preference of height was tested in a pear orchard. The ineffective heights of the traps were 2 and 2.5 m, whereas the effective heights were 1 and 1.5 m. Many captured males at 0.5, 1, and 5 m, and the number of captured males were similar in 10, 15, and 20 m. Male mealybugs were captured up to a distance of 50 m, suggesting that it is possible to control the male mealybugs that are more than 50 m away when sex pheromone traps are used.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

Automated Determination of Prostate Depth for Planning in Proton Beam Treatment (양성자치료에서의 종양의 위치 및 깊이 검출 자동화 시스템에 관한 연구)

  • Cheong, Min-Ho;Yoon, Myong-Geun;Kim, Jin-Sung;Shin, Dong-Ho;Park, Sung-Yong;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.180-190
    • /
    • 2009
  • Depth of prostate volume from the skin can vary due to intra-fractional and inter-fractional movements, which may result in dose reduction to the target volume. Therefore we evaluated the feasibility of automated depth determination-based adaptive proton therapy to minimize the effect of inter-fractional movements of the prostate. Based on the center of mass method, using three fiducial gold markers in the prostate target volume, we determined the differences between the planning and treatment stages in prostate target location. Thirty-eight images from 10 patients were used to assess the automated depth determination method, which was also compared with manually determined depth values. The mean differences in prostate target location for the left to right (LR) and superior to inferior (SI) directions were 0.9 mm and 2.3 mm, respectively, while the maximum discrepancies in location in individual patients were 3.3 mm and 7.2 mm, respectively. In the bilateral beam configuration, the difference in the LR direction represents the target depth changes from 0.7 mm to 3.3 mm in this study. We found that 42.1%, 26.3% and 2.6% of thirty-eight inspections showed greater than 1 mm, 2 mm and 3 mm depth differences, respectively, between the planning and treatment stages. Adaptive planning based on automated depth determination may be a solution for inter-fractional movements of the prostate in proton therapy since small depth changes of the target can significantly reduce target dose during proton treatment of prostate cancer patients.

  • PDF

Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators (진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교)

  • Han, Beom-Hui;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;You, In-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.389-394
    • /
    • 2012
  • In this study, based on IEC 60601-2-54 standard load conditions presented in the limited interval over the air kerma at the absolute linearity closely evaluated by measuring the X-ray results were as follows: 10 units targeted all Diagnostic X-ray generating device (DR) presented in the IEC 60601-2-54 standard linearity of air kerma emerged as inappropriate, the general evaluation of the dose linearity from four in the top 50% and 80 kVp % of the two measurement series were as irrelevant all the rest from six of the top tube voltage of 50% and 80% of the two measurement series, appeared in all suitable. Presented in IEC 60601-2-54 standard dose linearity testing and conventional linearity tests showed many differences. IEC 60601-2-54 standard linearity in the proposed international standards of air kerma is the recommendation of the existing dose linearity considerably more feasible, and to quantify the amount of radiation as the standard suggested by the standard IEC 60601-2-54 air kerma of a diagnostic X-ray imaging device linearity performance management is considered key elements in the critical appraisal.