• Title/Summary/Keyword: 방사선 피해

Search Result 77, Processing Time 0.037 seconds

A Study on the Effect of Containment Filtered Venting System to Off-site under Severe Accident (중대사고시 격납건물여과배기계통(CFVS)적용으로 인한 사고영향과 결과 고찰)

  • Jeon, Ju Young;Kwon, Tae-Eun;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.244-251
    • /
    • 2015
  • The containment filtered venting system reduces the range of the contamination area around the nuclear power plant by strengthening the integrity of the containment building. In this study, the probabilistic assessment code MACCS2 was used to assess the effect of the CFVS to off-site. The accident source term was selected from a Probabilistic Safety Analysis report of SHINKORI 1&2 Nuclear Power Plant. The three source term categories from 19 STC were chosen to evaluate the effective dose and thyroid dose of residents around the power plant and the dose with CFVS and without CFVS were compared. The dose was calculated according to the distance from the nuclear power plant, so the damage scale based on the distance that exceeds the IAEA criteria for effective dose (100 mSv per 7 days) and thyroid dose (50 mSv per 7 days) were compared. The effective dose reduction rates of the STC-3, STC-4, STC-6 were about 95-99% in the whole range (0~35 km), 96-98% for the thyroid dose. There are similar results between effective dose and thyroid dose. After applying the CFVS, the damage scale that exceeds the effective dose criteria was about 1 km (mean). Especially, the STC-4 damage scale was decreased from 26 km (mean) to 1.2 km (mean) significantly. The damage scale that exceed the thyroid dose criteria was decreased to 2~3 km (mean). The STC-4 damage scale was also decreased significantly as compared to STC-3, STC-6 in terms of effective dose.

An External Costs Assessment of the Impacts on Human Health from Nuclear Power Plants in Korea (국내원전운전(國內原電運轉)에 따른 보건영향(保健影響)의 외부비용평가(外部費用評價))

  • Kim, Kyoung-Pyo;Kang, Hee-Jung
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.67-76
    • /
    • 2008
  • As the first comprehensive attempt at a national implementation, this study aims at assessing the external costs of major electricity generation technologies in Korea, particularly an evaluation of the impacts on human health resulting from exposures to atmospheric radiological emissions from nuclear power plants, and a monetary quantification of their damages. The methodology used for the assessment of the externalities of the selected fuel cycles has been developed by the International Atomic Energy Agency (IAEA), namely the SimPacts Model Package. The model is internationally recognized as a tool which can be applied to a wide range of fuels, different technologies and locations, for an externalities study. In this study, the relevant emissions are quantified first and then their impacts on human health are evaluated and compared. The study focused on all the nuclear power plants for the last 6 years ($2001{\sim}2006$) in Korea. With respect to nuclear power, the impact analysis only focuses on a power generation, however the front- and back-end nuclear fuel cycles are not included, namely uranium mining, conversion, enrichment, reprocessing, conditioning, etc., because these facilities are not present in Korea. The analysis results show that nuclear power in general, generates low external costs. The highest damage costs from the nuclear power plants among the 4 sites in Korea were estimated to be 3.9 mills/MWh, which is about 1/20th of the result for a similar case study conducted in the U.K., implemented through the ExternE project. This difference is largely due to the number of radionuclides included in the study and the amount of released radioactive emissions based on up-to-date information in Korea. In this study, the sensitivities of the major factors for nuclear power plants were also calculated. The analysis indicates that there was around a ${\pm}3%$ damage costs variation to a ${\pm}15%$ change of the reference population density and a ${\pm}1%$ damage cost variation to a $1{\sim}30$ meters change of the effective release height, respectively. These sensitive calculations show that there is only a minor difference when the reference costs are compared.

Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area (방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로)

  • Yang, Won Seok;Choi, Jun-Hyeok;Shin, Woon-Jae;Min, Byung-In
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.768-777
    • /
    • 2013
  • The purpose of this study is to minimize radiation exposure to the workers and public members during CT examination. The objects are seven of the CT rooms in university hospitals and four of the CT rooms in clinics located in Busan and Gyung-nam area. The places of measurement for radiation leakage are 1) 3 m above the ground of shielding wall in the control room 2) particular space in the control room 3) worker's gate in the control room 4) the patient gate. Its values were calculated maximum leakage radiation per week(MLRW). As a result, the worker's gate of M clinic displayed the highest dose. When it was calculated by MLRW in classic method, it showed 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week. All of them did not exceed limit for maximum permissible dose per week(MPDW). However, When MLRW of M clinic was calculated by empirical method, its value displayed $118.31{\pm}17.72$ mR/week.(MPDW>100 mR/week). Radiation leakage influenced in the control room(p<0.05). Therefore, The way of calculating MLRW must be developed and shielding wall in control room is designed 3 m above the ground for reducing dangerous of leakage radiation.

A Study of Changes in the Primary Dose Penetrating the Protective Apron on SID in X-ray Radiography (X선촬영에서 보호앞치마를 투과한 1차 선량의 SID별 변화)

  • Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.501-507
    • /
    • 2016
  • This study is to figure out the amount of primary X-ray generated in SID 50cm, 1m, and 2m penetrating protective aprons in X-ray radiography for hands, skull, and lumbar spine. Results are as follows: Firstly, the exposure dose of primary X-ray which is low such as that of hand X-ray may be reduced by 270 times if protective aprons are worn, but it still slightly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Secondly, the exposure dose of primary X-ray which is moderate such as that of skull X-ray may be reduced by 22 times if protective aprons are worn, but it still fairly penetrates 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Thirdly, the exposure dose of primary X-ray which is very high such as that of lumbar spine X-ray may be reduced by 13 times if protective aprons are worn, but it still penetrates a lot 0.3mm thick Pb protective aprons at SID 50cm, 1m, and 2m. Therefore, people in X-ray room should not only wear protective aprons at any spaces that the primary X-ray can reach, but also need to stand behind the thick Pb shield to protect the body if it is inevitable to stay in the room.

Microbiological Hazard Analysis of Botanical Raw Materials used for Functional Health Foods and Preliminary Screening for Irradiation of Aloe Powder Products (건강기능식품 중 주요 식물성 원료에 대한 미생물학적 위해 분석과 알로에 제품에 대한 방사선 조사 가능성 검지)

  • Sung, Dong-Eun;Lee, Jee-Hye;Oh, Sang-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • Health functional foods refer to food which manufactured in the form of a tablet, capsule, granule or pill, using materials and ingredients with useful function for a human body in Korea. It needs to be confirmed as safe. Microbiological analyses on 37 samples of botanical raw materials used in the health functional food were performed. Microbiological analyses and probability of irradiation using PSL on 4 samples of aloe powder products were studied. In health functional food ingredients APC was $10^{3}-10^{6}\;CFU/g$ and coliform counts were $10^{2}-10^{5}\;CFU/g$. Among 37 samples B. cereus were found in 12 samples. Four samples of aloe powder products were tested for possible irradiation using preliminary PSL, Two samples of aloe powder products showed positive on preliminary PSL test for irradiation.

A Study of Applied Pressure According to Knee variable During Lachman Test for Anterior Cruciate Ligament using Telos Device (Telos Device를 이용한 전방십자인대 Lachman 검사 시 무릎두께와 활성도에 따른 인가압력에 대한 고찰)

  • Lim, Jong-Cheon;Kim, Sang-Hyuk;Seo, Sang-Hyuk;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.391-398
    • /
    • 2019
  • The purpose of study is to investigate the difference of the daN force applied during the examination using Telos Device and the degree of fluctuation of anterior cruciate ligament according to the individual differences of the muscles involved in knee stability. The examination was done by the Lachman test using Telos Device and the changes of anterior cruciate ligament were measured by varying the force of 0. 15, 30 daN on each right and left side and the force of 30 daN after the bruce protocol. Computed tomography (CT) was used to measure muscle mass. As a result of measuring the degree of fluctuation of the anterior cruciate ligament according to the change of the force applied to the Telos Device, there was a statistically significant difference in the knee fluctuation when 15 daN and 30 daN were applied on both right and left. Also, it is analyzed that the degree of fluctuation of anterior cruciate ligament varies according to the difference of individual's muscle mass. Therefore, it is considered that the force applied to the Telos Device should be changed according to the difference of individual's muscle mass.

Low Power and Long Range MAC Protocol for Inter-Drone communications based Sub-GHz Band (Drone간 Ad hoc통신 시스템을 위한 Sub-GHz 저전력 원거리 MAC Protocol 연구)

  • Lee, Joon beom;Min, Jin gi;Seo, Hyo-seung;Song, Dong hyuk;Kim, Hyeon jung;Son, Bong-ki;Lee, Jaeho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.90-93
    • /
    • 2016
  • 본 논문에서는 Sub-GHz band module을 Drone에 탑재하여 Drone과 전원공유로 Node(Drone)간 Low power and Long range Ad-hoc communication을 할 수 있는 방법을 제안하고자 한다. 또한 이동성이 있는 Node(Drone)의 Low power and Long range communication을 위해서 Drone에 적합한 Asynchronous MAC (medium access control) protocol을 비교분석하여 적용하였다. 본 고에서는 무선 센서 네트워크의 응용 범위가 확대되면서 고정된 인프라 없이 Drone간에 실시간 정보를 통신 할 수 있게 하고 사람의 이동이 어렵고 위험한 재난지역, 방사선노출지역 또는 우천시 유인기와 사람의 접근이 불가능한 지역을 Drone이 대신 이동하여 인명피해를 줄이고 안전하게 필요한 데이터를 수집하여 상황관제실로 전송하는 서비스를 제공하고자 한다.

A Study on the Overall Economic Risks of a Hypothetical Severe Accident in Nuclear Power Plant Using the Delphi Method (델파이 기법을 이용한 원전사고의 종합적인 경제적 리스크 평가)

  • Jang, Han-Ki;Kim, Joo-Yeon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Potential economic impact of a hypothetical severe accident at a nuclear power plant(Uljin units 3/4) was estimated by applying the Delphi method, which is based on the expert judgements and opinions, in the process of quantifying uncertain factors. For the purpose of this study, it is assumed that the radioactive plume directs the inland direction. Since the economic risk can be divided into direct costs and indirect effects and more uncertainties are involved in the latter, the direct costs were estimated first and the indirect effects were then estimated by applying a weighting factor to the direct cost. The Delphi method however subjects to risk of distortion or discrimination of variables because of the human behavior pattern. A mathematical approach based on the Bayesian inferences was employed for data processing to improve the Delphi results. For this task, a model for data processing was developed. One-dimensional Monte Carlo Analysis was applied to get a distribution of values of the weighting factor. The mean and median values of the weighting factor for the indirect effects appeared to be 2.59 and 2.08, respectively. These values are higher than the value suggested by OECD/NEA, 1.25. Some factors such as small territory and public attitude sensitive to radiation could affect the judgement of panel. Then the parameters of the model for estimating the direct costs were classified as U- and V-types, and two-dimensional Monte Carlo analysis was applied to quantify the overall economic risk. The resulting median of the overall economic risk was about 3.9% of the gross domestic products(GDP) of Korea in 2006. When the cost of electricity loss, the highest direct cost, was not taken into account, the overall economic risk was reduced to 2.2% of GDP. This assessment can be used as a reference for justifying the radiological emergency planning and preparedness.

Whiplash Injury Conditions of Rear-End Collisions at Low-Speed (저속 추돌사고에서 목 상해 조건에 대한 연구)

  • Kim, Myeongju;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.2
    • /
    • pp.58-76
    • /
    • 2019
  • As the number of reported injuries has tended to increase over time, large hospitalization expenditure from excessive medical treatments and hospitalization, and insurance frauds associated with moral hazard in minor collisions have caused a global societal problem. Many occupants of rear-ended vehicles involved in rear-end collisions complain of whiplash injury, which is also known as neck injury, without any anatomical and radiological evidence. With only clinical symptoms, stating that a whiplash injury is a type of injury defined by the Abbreviated Injury Scale would be difficult. Therefore, this study focuses on minor rear-end collisions, where the rear-ender vehicle collides with the rear-ended vehicle at rest. The mathematics dynamic model is employed to simulate a total of 100 rear-end collision scenarios based on various weights and collision speeds and identify how the weights and speeds of both vehicles influence the risk of whiplash injury in occupants involved in minor rear-end collisions. The possibility of an injury is very high when the same-weight vehicles are involved in accidents at collision speeds of 15 km/h or higher. The possibilities are 36% and 84% with collision speeds of 15 km/h and 20 km/h, respectively, if weights are disregarded.

Control of Lycoriella ingenua (Diptera: Sciaridae) in Exports of King Oyster Mushroom, Pleurotus eryngii, using Ionizing Radiation (이온화에너지를 이용한 수출용 큰느타리버섯의 긴수염버섯파리 방제)

  • Hyeonmo Ahn;Sun-Ran Cho;Hyun-Na Koo;Gil-Hah Kim
    • Korean journal of applied entomology
    • /
    • v.62 no.4
    • /
    • pp.333-343
    • /
    • 2023
  • King oyster mushrooms are one of the major fresh agricultural products which their exports are increasing every year in Korea. Lycoriella ingenua, is notorious insect pest in agriculture, especially in mushroom production. Larvae of L. ingenua cause mainly direct crop damage and adults are vectors of several dangerous fungal pathogens. In this study, the effects of electron beam, X-ray, and gamma-ray irradiation on the development and reproduction of L. ingenua were evaluated. In addition, to find the optimal dose to control L. ingenua in a box filled with king oyster mushrooms, an empirical experiment was conducted for each radiation. As a result, the development and reproduction of L. ingenua were inhibited at 50 Gy for all electron beam, X-ray, and gamma-ray irradiation. Additionally, at the top, middle, and bottom of the export box filled with king oyster mushrooms, the development and reproduction of L. ingenua were inhibited by electron beam with 150 Gy, X-ray with 100 Gy, and gamma-ray with 50 Gy. These results can be provided as basic data for establishing an integrated quarantine management system when exporting mushrooms. It will also contribute to the safety of agricultural products and the strengthening of export competitiveness.