• Title/Summary/Keyword: 방사선 이용통계

Search Result 572, Processing Time 0.033 seconds

Radiation Induced Changes in the Expression of Fibronectin, Pai-1, MMP in Rat Glomerular Epithelial Cell (백서 사구체 상피세포에서 방사선에 의한 Fibronectin, Pai-1, MMP 발현의 변화)

  • Park Woo-Yoon;Kim Won-Dong;Zheng Ying;Ha Tae-Sun;Kim Jae-Sung;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.58-66
    • /
    • 2006
  • Purpose: Renal irradiation can lead to the development of radiation nephropathy, and this is characterized by the accumulation of extracellular matrix and final fibrosis. To determine the possible role of the glomerular epithelial cell, the radiation-induced changes in the expression of its genes associated with the extracellular matrix were analyzed. Materials and Methods: Rat glomerular epithelial cells (GEpC) were irradiated with a single dose of 0, 2, 5, 10 and 20 Gy with using 6 MV LINAC (Siemens, USA), and the samples were collected 6, 24, 48 and 72 hours post-irradiation, respectively. Northern blotting, western blotting and zymography were used to measure the expression level of fibronectin (Fn), plasminogen activator inhibitor-1 (Pai-1), matrix metalloproteinases-2, 9 (MMP-2, 9), tissue inhibitor of metalloproteinase-2 (TIMP-2), tissue-type plasminogen activator (t-PA) and urokinase-type plasminogen activator (u-PA). Results: Irradiation with a single dose of 10 Gy resulted in a significant increase in Fn mRNA since 24 hours post-irradiation, and a single dose of 5 and 10 Gy significantly increased the Fn immunoreactive protein measured 48 hours post-irradiation. An increase in Pai-1 mRNA and protein was also observed and especially, a single dose of 10 Gy significantly increased the mRNA measured 24 and 48 hours post-irradiation. The active MMP-2 measured 24 hours post-irradiation slightly increased in a dose dependent manner, but this increase did not reach statistical significance. The levels of MMP-9, TIMP-2, t-PA and u-PA appeared unaltered after irradiation. Conclusion: Irradiation of the glomerular epithelial cells altered the expression of genes associated with the extracellular matrix, implying that the glomerular epithelial cell may be involved in the development of radiation nephropathy.

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

An Analysis of Intra-Fractional Movement during Image-Guided Frameless Radiosurgery for Brain Tumor Using CyberKnife (사이버나이프를 이용한 무고정틀 두개 방사선 수술 중 발생한 환자의 치료 중 움직임 분석)

  • Kang, Ki Mun;Chai, Gyu Young;Jeong, Bae Gwon;Ha, In-Bong;Park, Kyung Bum;Jung, Jin-Myung;Lim, Young Kyung;Jeong, Hojin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.169-176
    • /
    • 2012
  • Frameless method in brain radiosurgery has advantages relative to rigid head-frame method in terms of patient friendly and flexible application of multi-fractionation. However, it has also disadvantages and the most negative point is that it cannot control the patient motion during treatment as lowly as the level of the frame-based radiosurgery, which could affect to the treatment accuracy. In the present study, we analyzed the geometric uncertainty of the intra-fraction motion using the actual treatment records of 294-CyberKnife treatments for brain tumors. Based on the analysis, we statistically presented the magnitude of intra-fraction motion in frameless radiosurgy. The result could provide the quantitative information to determine the adequate treatment margins to compensate the intra-fraction movements.

Quantification of Experimentally Induced-Pleural Effusion in Beagle Dogs: Radiography versus CT and Ultrasonography (비글견에서 실험적으로 유발한 흉수의 정량 평가: 방사선, 컴퓨터단층촬영 및 초음파 검사 비교)

  • Lee, Ki-Ja;O, I-Se;Jeong, Seong-Mok;Lee, Hee-Chun;Park, Seong-Jun;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.96-101
    • /
    • 2008
  • This study was performed to quantify the pleural effusion in radiography, ultrasonography and computed tomography(CT) and to evaluate and compare the usefulness of these methods. Normal saline of 10 ml/kg was infused into the pleural space until a final loading volume of 60 ml/kg body weight was reached in six Beagle dogs. The radiographic examination was performed for the detection and quantification of pleural effusion. On the ultrasonographic study, the maximum perpendicular distance was measured between the surface of the lung and the thoracic wall to evaluate pleural effusion. On the CT image, pleural effusion was evaluated as the perpendicular distance to the thoracic surface in the maximum pleural effusion volume on any transverse images with soft tissue window. Statistical analysis was performed using linear regression test. The volume of pleural effusion and measurements of radiography and ultrasonography had no statistical relationship. However, a significant correlation was identified between the volume of pleural effusion and the depth at right ($r^2=0.715$), left ($r^2=0.745$), and mean right and left depth ($r^2=0.844$) on the CT images. All of the thoracic radiographs, ultrasonography, and CT are useful in recognition of pleural effusion. In quantification of pleural effusion, the CT measurement method is superior to radiographic and ultrasonographic measurements.

The Effect of Smart Media Literacy and Ego-Resilience on the Academic Achievement of Radiologic Science(Technology) Students (방사선(학)과 학생들의 스마트미디어 활용 역량과 자아탄력성이 학업성취도에 미치는 영향)

  • Na, Gil-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The purpose of this study was to confirm the degree of academic achievement among university students in the Department of Radiology(science) who are in the continuation of the COVID-19 situation and to investigate the effect of smart media literacy and ego-resilience on academic achievement. The research method was descriptive research. Data was 188 students collected from June 1 to July 31 in 2021 using structured questionnaires as students in the Department of Radiology(science). Collected data was analyzed using descriptive statistics, t-test, ANOVA, Cronbach's pearson's correlation, multiple regression analysis with SPSS/WIN 21.0. The result of the study showed that the academic achievement was 3.43, ego-resilience was 3.37 and smart media literacy was 2.94. There was a significant positive correlation between a academic achievement and smart media literacy, academic achievement and ego-resilience. Factors influencing academic achievement were smart media literacy, ego-resilience, major satisfaction and practice satisfaction. As a result of the above research. it is necessary to develop and apply curriculums, extra curriculums and educational programs that improve the smart media literacy and ego-resilience in order to improve the academic achievement. In addition, it is necessary to improve major satisfaction and practice satisfaction.

Effect of Other Behaviors on Self-Directed Learning Ability, Flow and Academic Achievement of Department of Radiology(science) Students in Online Classes (온라인 수업에서 방사선(학)과 학생들의 딴짓이 자기주도적 학습역량, 몰입, 학업성취도에 미치는 영향)

  • Na, Gil-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.611-618
    • /
    • 2022
  • The purpose of this study was to confirm the degree of other behaviors among university students in the department of radiology(science) who experienced online classes in the COVID-19 situation and to investigate the effect of self-directed learning ability, flow and academic achievement on other behaviors. The research method was descriptive research. Data were 200 students collected from June 1 to 30 in 2022 using structured questionnaires as students in the Department of Radiology(science). Collected data were analyzed using descriptive statistics, t-test, ANOVA, Cronbach's pearson's correlation, multiple regression analysis with SPSS/WIN 21.0. The result of the study showed that the other behaviors were in the order of 'having s different thought, and 'sending text messages'. other behaviors was 1.75, self-directed learning ability was 3.60, flow was 3.23 and academic achievement was 4.29. There was a significant negative correlation between other behaviors and self-directed learning ability, flow, academic achievement. Factors influencing other behaviors were academic achievement, age, flow, self-directed learning ability in that order. As a result of the above research. it is expected that specific measures and various teaching methods to be flowed in the class are need as the way to lower the other behaviors of university students in the Department of Radiology(science) is to increase academic achievement.

Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer (자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화)

  • Park, Won;Huh, Seung-Jae;Lee, Jeung-Eun
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Purpose: The purpose of this study was to investigate the positional change of the uterus during radiotherapy. Materials and Methods: Between 1997 and 2001, 47 patients received definitive radiotherapy for cervical cancer at the Samsung Medical Center. For each patient, two MRI scans were taken; one before and the other 3$\~$4 weeks after the radiotherapy treatment. In T2 weighted MRI images, the positional change of the uterine was quantified by measuring six quantities; the distance from the cervix os to the isthmus of the uterus (Dcx), the maximum length from the isthmus of the uterus to the uterine fundus (Dco), the maximum vertical distance of the uterine body (Dco-per), the angle between the vertical line and the cervical canal in the sagittal images (Acx), the angle of the uterine corpus from the vertical line in the sagittal plan (Aco-ap), and the relative angle of the uterine corpus from a fixed anatomical landmark in the axial images (Aco-axi). Results: The mean Dcx values, before and during the treatment, were 36.7 and 27.8 mm, respectively. The Dco deviated by more than 10 mm in 14 cases (29.8$\%$). The change in the Acx ranged from 0.1 to 67.8$^{\circ}$ (mean 13.2$^{\circ}$). The Aco-ap changed by a maximum of 84.8$^{\circ}$ (mean 16.9$^{\circ}$). The differences in the Dcx plus the Dco in the smaller (<4 cm) and larger ($geq$4 cm) tumors were 5.3 and 19.4 mm, respectively. With patients less than 60 years old, or with a tumor size larger than 4 cm, the difference in the Acx was statistically significant. Conclusion: The positional changes of the uterus, during radiation treatment, should be considered in the 3DCRT or IMRT treatment planning, particularly in patients under 60 years of age or in those with a tumor size greater than 4 cm in maximum diameter.

Dosimetric Advantages of the Field-in-field Plan Compared with the Tangential Wedged Beams Plan for Whole-breast Irradiation (유방암 환자의 방사선치료에 있어서 순치료계획 세기변조방사선치료법과 쐐기접선조사기법의 선량측정 비교)

  • Kim, Suzy;Choi, Yunseok
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.199-204
    • /
    • 2014
  • The purpose of this study is to evaluate the dosimetric outcome of the field-in-field (FIF) plans compared with tangential wedged beams (TWB) plans for whole breast irradiation of breast cancer patients. Twenty patients with right-sided breast cancer and 10 patients with left-sided breast cancer were retrospectively enrolled in this study. We generated a FIF plan and a TWB plan for each patient to compare dosimetric outcomes. The dose the homogeneity index (HI), the conformity index (CI) and the uniformity index (UI) were defined and used for comparison of the dosimetric outcome of the planning target volume (PTV). To compare the dosimetric outcome of the organs at risk, the mean dose ($D_{mean}$) and the percentage of volumes receiving more than 10, 20 and 30 Gy of the ipsilateral lung and heart were used. The FIF plans had significantly lower HI (p=0.002), higher UI (p=0.000) and CI (p=0.000) than those of the TWB plans, which means that the FIF plans were better than the TWB plans in the dosimetric comparisons of the PTV. The $V10_{lung}$ ($17.1{\pm}7.1$ vs. $18.6{\pm}6.6%$, p=0.020) and $V30_{lung}$ ($10.3{\pm}5.1%$ vs. $10.7{\pm}5.2%$, p=0.000) were lower with the FIF plans compared with those of the TWB plans, with statistical significance. For the left-sided breast cancer patients, $D_{mean}$ of the heart ($2.6{\pm}1.3$ vs. $3.2{\pm}1.4$ Gy, p=0.000), $V20_{heart}$ ($3.4{\pm}2.6$ vs. $3.6{\pm}2.8%$, p=0.005) and $V30_{heart}$ ($2.6{\pm}2.3%$ vs. $2.9{\pm}2.4%$, p=0.004) were significantly lower for the FIF plans in comparison with those of the TWB plans. The FIF plans increased the dose homogeneity, conformity and uniformity of the target volume for the whole-breast irradiation compared with the TWB plans. Moreover, FIF plans reduced the doses to the ipsilateral lung and heart.

Detection of Irradiated Beef and Pork by DNA Comet Assay (DNA Comet Assay를 이용한 방사선 조사 쇠고기와 돼지고기의 검지 기술)

  • 박준영;오경남;김경은;양재승
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.6
    • /
    • pp.1025-1029
    • /
    • 2000
  • This study was conducted to investigate whether a DNA comet assay could be applied for identifying irradiated pork and beef. Pork and beef were irradiated with Co-60 gamma rays at 0.1, 0.3, 0.5, 0.7 and 1.0 kGy, and stored in a freezer Cells separated from the samples were embedded in agarose gel on a slide, dissolved in a lysis solution, and electrophoresed at 2 V/cm for 2.0 min by horizontal electrophoesis. The cells were then stained with a silver staining in order to visualize the DNA using a micro-scope. The DNA fragments of the irradiated cells stretched or migrated out of the cells and formed tails towards the anode, giving the appearance of comets, while unirradiated cells formed very short or no tails. The distance of DNA migration increased with irradiation dose. Since the statistical analysis showed a significant correlation between tail length and irradiation dose, a DNA comet assay could provide not only identification but also estimation of the irradiation dose for irradiated beef and pork.

  • PDF