• Title/Summary/Keyword: 방사선 이용통계

Search Result 567, Processing Time 0.027 seconds

A Comprehensive Dosimetric Analysis of Inverse Planned Intensity Modulated Radiation Therapy and Multistatic Fields Technique for Left Breast Radiotherapy (좌측 유방 방사선치료를 위한 역치료계획의 세기변조방사선치료와 다중빔조사영역치료기법 사이의 포괄적 선량측정 분석)

  • Moon, Sung-Kwon;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.39-49
    • /
    • 2010
  • Purpose: This aim of this study is to analyze the dosimetric difference between intensity-modulated radiation therapy (IMRT) using 3 or 5 beams and MSF in the radiotherapy of the left breast. Materials and Methods: We performed a comparative analysis of two radiotherapy modalities that can achieve improved dose homogeneity. First is the multistatic fields technique that simultaneously uses both major and minor irradiation fields. The other is IMRT, which employs 3 or 5 beams using a fixed multileaf collimator. We designed treatment plans for 16 early left breast cancer patients who had taken breast conservation surgery and radiotherapy, and analyzed them from a dosimetric standpoint. Results: For the mean values of $V_{95}$ and dose homogeneity index, no statistically significant difference was observed among the three therapies. Extreme hot spots receiving over 110% of the prescribed dose were not found in any of the three methods. A Tukey test performed on IMRT showed a significantly larger increase in exposure dose to the ipsilateral lung and heart than multistatic fields technique (MSF) in the low-dose area, but in the high-dose area, MSF showed a slight increase. Conclusion: In order to improve dose homogeneity, the application of MSF, which can be easily planned and applied more widely, is considered an optimal alternative to IMRT for radiotherapy of early left breast cancer.

아조 화합물을 함유한 LDPE의 방사선 열화

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Oh, Tae-Seung;Lee, Chung
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.301-306
    • /
    • 2000
  • 케이블 절연파괴 사고에 관한 여러 통계에서 사고원인을 검토하여 보면, 전기트리, 열화, 침수의 순서로 발생하였으며, 전기트리에 의한 사고가 60%이상을 차지하고 있다[1]. 전기트리에 관한 억제책으로는 제조공정상의 개선, 블렌드 또는 공중합체를 이용하는 방법 또는 첨가제를 혼합하여 특성을 개선시키는 방법 등이 있다. 공정상의 개선은 어느 정도 한계에 이르렀으며, 공중합체를 만드는 것은 반응기를 수정해야 하는 어려움이 따라 활발하게 이용되지 못하고 있다.(중략)

  • PDF

Bladder volume variations of cervical cancer patient in radiation therapy using ultrasonography (초음파검사를 이용한 자궁경부암 환자의 방사선치료 시 방광 체적 변화)

  • Gong, Jong Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • Purpose : The bladder volume change was measured using ultrasonography for helping decrease the side effects and other organ variations in the location of radiation therapy for cervical cancer patients. An experiment was performed targeting patients who were treated with radiation therapy at PNUH within the period from September to December 2015. Materials and Methods : To maintain the bladder volume, each patient was instructed to drink 500 cc water before and after CT simulation, 60 minutes before the dry run. Also, the bladder volume was measured in each patient CT scan, and a 3D conformal therapy plan was designed. The bladder volumes measured before and after the CT simulation, dry run, and radiation treatment planning were compared and analyzed. Results : The average volume and average error of the bladder that were obtained from the measurement based on the CT scan images had the lowest standard deviation in the CT simulation. This means that the values that were obtained before and after the CT simulation were statistically relevant and correlative. Moreover, the bladder volume measured via ultrasonography was larger size, the average volume in the CT scan. But the values that were obtained Dry run and after the CT simulation were not statistically relevant. Conclusion : Drinking a certain amount of water helps a patient maintain his/her bladder volume for a dry run. Even then, it is difficult to maintain the bladder volume for the dry run. Also, whether or not the patients followed the directions for the dry run correctly is important.

  • PDF

Reproducibility Evaluation of Shear Wave Elastography According to the Depth of the Simulated Lesion in Breast Ultrasonography (유방초음파 검사에서 모조 병소의 깊이에 따른 전단파 탄성초음파의 재현성 평가)

  • Jin-Hee Kim;In-Soo Kim;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.919-927
    • /
    • 2023
  • Elastography utilizes the fact that the tissue of a malignant tumor is harder than that of a benign tumor and increases the specificity of diagnosis according to the elastic modulus of the tumor, helping to reduce unnecessary biopsies. However, the reliability of elastography can be influenced by the equipment used and the examiner's skills. In this study, the researchers analyzed the reproducibility of elastography by evaluating phantom images when measuring the elasticity values repeatedly. Phantoms were created using silicone and gelatin with different levels of stiffness, and they were inserted at varying depths from the surface. The elasticity values were measured using shear wave elastography. The study aimed to determine whether the reproducibility of elasticity values remains consistent depending on the stiffness and depth of the lesions. The experimental results showed that there was no statistically significant correlation between the elasticity values obtained through shear wave elastography and the depth or stiffness of the lesions. However, in the lesions with the lowest stiffness, the elasticity values were statistically significant (p<0.001) and showed a high correlation with the depth of the lesions. Although there were variations in the measured elasticity values based on the differences in lesion stiffness and depth, these differences did not significantly impact the diagnosis. Therefore, shear wave elastography remains a reliable diagnostic method, and it is suggested that it can be helpful in the diagnosis of breast lesions.

Gynecologic Patients' Recognition of Radiation Exposure in Gyeongbuk Area (경북 지역 산부인과 환자의 방사선피폭 인식)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.8
    • /
    • pp.176-187
    • /
    • 2008
  • As the radiological medical instruments have been competitively developed in recent years, its utilization for the patient treatment has been expanded. The medical examination using the radiation has been gradually increased, so that it is recognized as a significant factor of increasing the radiation exposure. In this study, the recognition about the radiation exposure was analyzed for 555 gynecologic patients in 8 secondary and tertiary medical centers in Gyeongbuk from November 17 to April 19, 2007. The results are followed. There was a significant difference on the recognition for the radiation by age and education (p<0.05), There was the significant difference in the recognition about the radiological instruments by age and occupation (p<0.05), and there was the significant difference in the information identification & analysis by age and occupation (p<0.05). As the result of analyzing a correlation of the radiation's harmfulness, recognition, psychological state and exposure prevention, there was the correlation of 0.572 between the harmfulness and recognition, the correlation of 0.740 between the harmfulness and the psychological state, and the correlation of 0.477 between the harmfulness and the exposure prevention. It was statistically very significant (p<0.01). But, there was no significance with the radiological instrument and information identification (p>0.05). As the result of the study, it could be known that the mental threat factor was more included than the physical threat from the position of gynecologic patients who were sensitive to the radiation. Accordingly, radiological technologist who manages the radiation needs to let the patient or its guardians recognize the degree of physical harmfulness exactly.

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Treatment Outcome of Mandibular Advancement Device in Obstructive Sleep Apnea Patients- Polysomnographic and Cephalometric analyses (수면무호흡증 환자에서 수면다원검사와 두부규격방사선사진을 이용한 하악전방이동장치의 치료효과에 관한 연구)

  • Chung, Jin-Woo;Kim, Ebee;Kim, Sung-Hun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.203-213
    • /
    • 2013
  • Objecives : The purpose of the study was to evaluate treatment outcome of mandibular advancement device(MAD) in obstructive sleep apnea (OSA) patients using full night polysomnography and cephalometry. Methods : Twenty-seven OSA patients were confirmed by full night, lab-attended polysomnography. Cephalometric examinations were conducted to obtain SNA, ANB, $AH{\bot}MP$, AH-C3, SPT, PNS-U, NAS, SOAS, MOAS, and HAS. Mandibular advancement devices (MADs) were fabricated and delivered for all subjects. After acclimation period of MAD, the second polysomnographic examinations were conducted in the same manner. Polysomnographic variables were compared between before and after MAD placement. Also, correlation coefficients were calculated between apnea-hypopnea index (AHI) and each item of cephalometric parameters. Results : There were significant improvements in total AHI, lowest $SpO_2$, and total arousal index after MAD therapy. Also, there were significant improvements in NREM $SpO_2$ and NREM AHI, but not in REM $SpO_2$ and REM AHI with MAD. Stratifying the sleep stage, there were significant decrease in stage I and significant increases in stage II and REM, but change in stage III was not significant. SNA and SOAS were significantly correlated with total AHI and NAS was significantly correlated with supine AHI. ANB was significantly associate with the effect of MAD. Conclusions : MAD is an effective treatment in OSA patients comparing polysomnographic variables before and after treatment. Cephalometric examination can be useful to evaluate OSA patients and predict treatment outcome of MAD.

The Effect of Pentoxifylline on Radiation-Induced Cardiac Injury in ICR Mice (방사선조사후 발생한 심장손상에서 Pentoxifylline 이 미치는 효과)

  • Suh Hyun Suk;Yang Kwang Mo;Kang Seung Hee;Kang Yun Kyung
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.281-290
    • /
    • 1996
  • Purpose : Chest irradiation leads to a significant cardiac injury in a number of patients. To prevent, or to reduce the risk of radiation-induced cardiac injury, pentoxifylline(PTX), a haemorrheologic agent that improves the blood flow through small blood capillaries has been employed. Materials and Methods : One hundred and eighty ICR mice were divided into three study groups: control, radiation alone, and radiation-pentoxifylline. Each group was subdivided into 12 subgroups: 1 3, 6 and 10 days and 2, 3, 4, 6, 8, 12, 16 and 20 weeks by observation Period after irradiation. The total 15Gy of radiation was delivered in a single fraction through anterior mediastinal port. Pentoxifylline was injected subcutaneously daily 50mg/kg to the back of the mice from the first day of irradiation throughout the observation period. The mice of each group after a certain observation period were sacrificed and sectioned for histopathologic examination of the heart. Result : The findings of acute radiation-induced carditis i.e., heterophilic infiltration and vacuolization and ballooning of endothelial cells were observed upto 6 weeks and reduced sharply afterwards. The late radiation effects including pericarditis with mononuclear cell infiltration, pericardial fibrosis, endothelial cell changes, myocardial degeneration and fibrosis present from 4 weeks onwards after irradiation but with various degree of severity. The overall process of pathologic changes of radiation-pentoxifylline group was similar to those of radiation alone group but the duration of acute stage was relatively short and the severity of late cardiac toxicity was much lesser compared with those of radiation alone group. Conclusion : Pentoxifylline can effectively reduce the late radiation-induced cardiac injury and reslve the acute effects relatively rapidly.

  • PDF

Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT (ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가)

  • Hyun-Jun, Ahn;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.905-917
    • /
    • 2022
  • This study was conducted to evaluate the use of the MAR function and the image quality of the image when examining with each radiation dose. A simple Periapical phantom was made to set up an implant, and images were obtained and analyzed according to the presence or absence of MAR function for each radiation dose using CBCT equipment. In this study, MEAN, SNR, and CNR values were obtained using the Image J program, and through statistical analysis, images were the most quantitative and suitable values when the Abutment of Implant was 100 kVp and 8 mA, and when the Center of Implant and Apex of Implant were 100 kVp and 9 mA. As a result, it was confirmed that if the radiation dose increased, the Pixel Value, SNR, and CNR values of the image rose up so that the quality of the image improved, and using the MAR function reduced artifacts.