• Title/Summary/Keyword: 방사선 영향평가

Search Result 741, Processing Time 0.023 seconds

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

Reproducibility Evaluation of Shear Wave Elastography According to the Depth of the Simulated Lesion in Breast Ultrasonography (유방초음파 검사에서 모조 병소의 깊이에 따른 전단파 탄성초음파의 재현성 평가)

  • Jin-Hee Kim;In-Soo Kim;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.919-927
    • /
    • 2023
  • Elastography utilizes the fact that the tissue of a malignant tumor is harder than that of a benign tumor and increases the specificity of diagnosis according to the elastic modulus of the tumor, helping to reduce unnecessary biopsies. However, the reliability of elastography can be influenced by the equipment used and the examiner's skills. In this study, the researchers analyzed the reproducibility of elastography by evaluating phantom images when measuring the elasticity values repeatedly. Phantoms were created using silicone and gelatin with different levels of stiffness, and they were inserted at varying depths from the surface. The elasticity values were measured using shear wave elastography. The study aimed to determine whether the reproducibility of elasticity values remains consistent depending on the stiffness and depth of the lesions. The experimental results showed that there was no statistically significant correlation between the elasticity values obtained through shear wave elastography and the depth or stiffness of the lesions. However, in the lesions with the lowest stiffness, the elasticity values were statistically significant (p<0.001) and showed a high correlation with the depth of the lesions. Although there were variations in the measured elasticity values based on the differences in lesion stiffness and depth, these differences did not significantly impact the diagnosis. Therefore, shear wave elastography remains a reliable diagnostic method, and it is suggested that it can be helpful in the diagnosis of breast lesions.

Automatic Segmentation of the Prostate in MR Images using Image Intensity and Gradient Information (영상의 밝기값과 기울기 정보를 이용한 MR영상에서 전립선 자동분할)

  • Jang, Yj-Jin;Jo, Hyun-Hee;Hong, Helen
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.9
    • /
    • pp.695-699
    • /
    • 2009
  • In this paper, we propose an automatic prostate segmentation technique using image intensity and gradient information. Our method is composed of four steps. First, rays at regular intervals are generated. To minimize the effect of noise, the start and end positions of the ray are calculated. Second, the profiles on each ray are sorted based on the gradient. And priorities are applied to the sorted gradient in the profile. Third, boundary points are extracted by using gradient priority and intensity distribution. Finally, to reduce the error, the extracted boundary points are corrected by using B-spline interpolation. For accuracy evaluation, the average distance differences and overlapping region ratio between results of manual and automatic segmentations are calculated. As the experimental results, the average distance difference error and standard deviation were 1.09mm $\pm0.20mm$. And the overlapping region ratio was 92%.

Study on Methods to Improve Image Quality of Abdominal CT Images (복부 CT 영상의 화질 개선 방법에 대한 연구)

  • Seok-Yoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.717-723
    • /
    • 2023
  • Liver disease is highly associated with death, and other abdominal diseases are also important causes affecting a person's lifespan, and a CT scan is essential when treating abdominal diseases. High radiation exposure is essential to create images that are good for reading, but managing the patient's radiation exposure is also essential. In this study, a post-processing wavelet algorithm was proposed to improve the image quality of abdominal CT images. Wavelets have the disadvantage of having to set a threshold value depending on the type of input image. Therefore, we experimentally proposed the threshold value of the wavelet and evaluated whether the image quality was effective. As a result of the experiment, the optimal threshold value for abdominal CT images was calculated to be 50. In the case of image 1, noise was improved by 49% and in the case of image 2, by 29%, and the contrast also increased. if the results of this study are applied for post-processing after abdominal CT, image quality can be improved and it will be helpful in disease diagnosis.

Analysis of Learning Effects MRI Education Content based on Virtual Reality (가상현실 기반 MRI 교육 콘텐츠 학습효과 분석)

  • Jung-Hun Lee;Jae-Goo Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2023
  • In order to overcome practical limitations in installing, managing and operating MRI machines with expensive equipment, this study developed and utilized virtual reality (VR) experience education by combining virtual reality (VR) with magnetic resonance imaging devices. The Students who experienced virtual reality-based educational systems were surveyed to identify possible side effects during the experience and self-directed learning ability and academic self-efficacy surveys were conducted to analyze the impact of virtual reality-based practice on learning. In the analysis of the self-directed learning ability survey there was no difference in the average between the student group who experienced education and the student group who did not but there was a significant difference in the average for each group. Virtual Reality-based practical education is expected to provide an efficient practice system by providing new learning methods and opportunities for education that can be repeated anytime, anywhere regardless of time and space.

The vertical changes of the lip and perioral soft tissue resulting from incisor retraction (전치의 후방견인에 따른 입술과 주위 연조직의 수직적 변화)

  • Kang, Chang-Soo;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.185-196
    • /
    • 2000
  • Patients who want to reduce their lip protrusion usually estimate the severity of the lip protrusion on the frontal aspect. Most orthodontists have a perplexed experience of a reduced thin line of vermilion border on the frontal aspect as incisors we retracted, even though the lip protrusion is thought to be reduced favorably on the sagittal aspect. Some patients also look older after orthodontic treatment because of severe lip thinning. This unaesthetic reduction of vermilion border urges us to study the vertical lip change during orthodontic procedure. The purpose of this study was to evaluate the vertical lip and perioral soft tissue changes in respect to incisor retraction in an effort to analyze which factors might be responsible for their vertical changes, using the multiple regression analysis. The results were as follows. 1. Upper and lower lip philtrum length(SnLs, LiB') were increased after retraction of anterior teeth, where as upper and lower vermilion height(LsSuls, StmiLi), and vermilion length(LsLi) were decreased. 2. Upper and lower lip length(SnStms, StmiB'), and soft tissue lower anterior facial height(SnMe') did not show any significant difference after treatment. 3. The increase of the upper lip philtrum length was mainly influenced by the extrusion of upper anterior teeth(${\Delta}U1V$), and the increase of the lower lip philtrum length was mainly influenced by the initial overjet before treatment. 4. The decrease of the upper and lower lip vermilion height was mainly influenced by the decrease of upper lip thickness.

  • PDF

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

A Study on the Overall Economic Risks of a Hypothetical Severe Accident in Nuclear Power Plant Using the Delphi Method (델파이 기법을 이용한 원전사고의 종합적인 경제적 리스크 평가)

  • Jang, Han-Ki;Kim, Joo-Yeon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Potential economic impact of a hypothetical severe accident at a nuclear power plant(Uljin units 3/4) was estimated by applying the Delphi method, which is based on the expert judgements and opinions, in the process of quantifying uncertain factors. For the purpose of this study, it is assumed that the radioactive plume directs the inland direction. Since the economic risk can be divided into direct costs and indirect effects and more uncertainties are involved in the latter, the direct costs were estimated first and the indirect effects were then estimated by applying a weighting factor to the direct cost. The Delphi method however subjects to risk of distortion or discrimination of variables because of the human behavior pattern. A mathematical approach based on the Bayesian inferences was employed for data processing to improve the Delphi results. For this task, a model for data processing was developed. One-dimensional Monte Carlo Analysis was applied to get a distribution of values of the weighting factor. The mean and median values of the weighting factor for the indirect effects appeared to be 2.59 and 2.08, respectively. These values are higher than the value suggested by OECD/NEA, 1.25. Some factors such as small territory and public attitude sensitive to radiation could affect the judgement of panel. Then the parameters of the model for estimating the direct costs were classified as U- and V-types, and two-dimensional Monte Carlo analysis was applied to quantify the overall economic risk. The resulting median of the overall economic risk was about 3.9% of the gross domestic products(GDP) of Korea in 2006. When the cost of electricity loss, the highest direct cost, was not taken into account, the overall economic risk was reduced to 2.2% of GDP. This assessment can be used as a reference for justifying the radiological emergency planning and preparedness.

Postoperative Radiotherapy for Locally Advanced Gastric Cancer (국소적으로 진행된 위암의 수술후 방사선 치료성적)

  • Lee Myung Za;Chun Ha Chung;Kim Insoon;Chung Tejune
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.113-119
    • /
    • 1997
  • Purpose : Radical gastrectomy is main treatment of gastric cancer. But the result is not satisfactory with surgery alone. Most of pattern of failure remain locoregional recurrence. To improve 5 year survival postoperative chemotherapy with or without radiotherapy has been used. We analyzed patients with stage III and IV stomach cancer who had radical operation and received postoperative radiation therapy combined with or without chemotherapy retrospectively. Material and Method : From March 1985 to June 1993, 68 patients treated with curative resection and received postoperative adiuvant radiotherapy with 36Gy or more were evaluated. Median age was 60 years(range 28-66 yrs) . Patients were followed from 3 to 133 months with median follow up of 48 months. Thirty seven patients had non signet ring adenocarcinoma, 29 signet ring cell, 2 other cell. Patients with stage IIIA, IIIB, IV disease were 19, 25 and 24 respectively Chemotherapy was given to all patients except two. Results : Five-year overall survival and disease-free survival rate were 36.6% and 33.6%, respectively. Prognostic factor affecting survival were assessed. High ratio of jnvolved/dissected Iymph node, signet ring histology showed Poor Prognosis with statistical significance. Presence of residual tumor after surgery, stageIV. split course of radiation therapy, age, number of involved Iymph node, number of Iymph node dissection and grade of tumor affected survival without statistical significance, Type of chemotherapy did not affect survival. Recurrence was documented in 34 patients. High recurrence was seen in omentum and peritoneum with 23.5%, and remnant stomach, anastomosis site, A-loop and I-loop had also high recurrence with 13.2%. In field locoregional recurrence was 20.7% and total distant metastases were 39.7%. Total intraabdominal failure was 47.1% and extraabdominal failure was 13.2%. Treatment toxicity was considered to be acceptable. 22.1% of patients had grade 3 and only 1 patient had grade 4 leukopenia. Six Patients(8.8%) had weigh loss more than 10%. Conclusion : Treatment toxicity was acceptable with combined treatment with chemotherapy and radiotherapy. Locoregional recurrence was relatively low compared to distant failure with addition of irradiation. Peritoneal and omental seeding was high Five-rear surival was increased with combined modality. Radiation may eradicate minimal residual disease and improve survival, To evaluate role of radiation Prospective randomized study employing chemotherapy alone and chemotherapy plus radiation is necessary. Futhermore to reduce intraabdominal failure, role of intraabdominal chemotherapy in addition to combined chemotherapy plus radiation has to be explored.

  • PDF