• Title/Summary/Keyword: 방사선 선량 분포

Search Result 726, Processing Time 0.027 seconds

Energy Distribution of X-rays from Medical Linear Accelerator (의료용 선형 가속기에서 발생된 X-선의 에너지 분포에 대한 고찰)

  • 김진기;김정홍;김부길
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • For accureate treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the X-rays incident on the surface of the material. In this present study, we applied the Monte Carlo methods to the systematic analysis of the spectra distribution of X-ray beams produced by medical linear accelerator. As expected, the spectra become softer as the distance is farther from the central axis. also, its influenced by the geometrical dffect of head system.

  • PDF

Quality Assurance of CORVUS Planning System for Intensity Modulated Radiation Therapy (CORVUS Planning System을 사용한 세기조절방사선치료의 정도관리에 관한 연구)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • The intensity modulated radiation therapy (IMRT) is believed to be on of the best treatment techniques for the goal of radiation therapy: to irradiate fatal dose to tumor region while minimizing dose to critical organs. It is essential to have comprehensive quality assurance program to assure the precision and the accuracy of the treatment due to the characteristic of the IMRT. The quality assurance technique for the Corvus treatment planning system was developed and its effectiveness was tested with the treatment planning of H&N region. Acrylic phantom, film and ionization chamber were used for this study, the discrepancy between the treatment planning and the film measurements showed 0.03 cm and 0.28 cm for the 90% of isodose line in each directions. Dose measurements showed 1% and 1.2% differences for ionization chamber and TLD, respectively. This concluded that the system can be used for clinic.

  • PDF

Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer (전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가)

  • Heo, Kwangmyoung;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.449-457
    • /
    • 2015
  • In this study, to evaluate the usefulness of the treatment plan of tomotherapy and volumetric modulated arc therapy (VMAT) in the radiotherapy for prostate cancer, the absorbed dose, dose volume histogram (DVH), treatment efficiency, and the results of dose verification accuracy using MapCHECK2 were compared and analyzed. Of the prostate cancer patients who underwent tomotherapy treatment in the Radiologic Oncology of H University Hospital between July 2014 and December 2014, 12 patients were randomly selected. As a result of analyzing the absorbed dose and DVH, both radiologic treatment plans showed slight differences in the treatment of the cancer tissues and the bladder, but the difference was in the error range of -5% to +3%, and did not exceed the side effect guideline or the tolerance dose limit. VMAT showed higher treatment efficiency than tomotherapy with a 2.5 times shorter treatment time and a 10.3 times less monitor unit (MU). Both showed 95% or higher dose accuracy satisfying the standard. VMAT showed 2.3% higher efficiency than tomotherapy. In both tomotherapy and VMAT, appropriate doses were absorbed for cancer tissues, and did not exceed the tolerance dose for normal tissues showing no significant difference in dose distribution. However, considering the shorter treatment time, lower total MU, and better treatment efficiency and dose verification accuracy, VMAT may be more useful than tomotherapy in cancer treatments.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.

Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging (방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구)

  • Song, Keun-Young;Hwang, Young-Gwan;Lee, Nam-Ho;Na, Jun-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1535-1541
    • /
    • 2019
  • To carry out safe and rapid decontamination in radiological accident areas, acquisition of various information on radiation sources is needed. In particular, to figure out the location and distribution of radiation sources is essential for rapid follow-up and removal of contaminants as well as minimizing worker damage. The radiation distribution detection device is used to obtain the position and distribution information of the radiation source. In the case of a radiation distribution detection device, a detection sensor unit is generally composed of a single sensor, and the detection range is limited due to the physical characteristics of the single sensor. We applied a calibration detector for controlling the detection sensitivity of a single sensor for radiation detection and improved the limited detection range of radiation dose rate. Also, gamma irradiation test confirmed the improvement of radiation distribution detection range.

Estimation of the Characteristics for the Dose Distribution in the Polymer Gel by Means of Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 양성자 조사에 따른 Polymer Gel 내부의 선량 분포 특성 평가)

  • Park, Min-Seok;Kim, Gi-Sub;Jung, Hai-Jo;Park, Se-Young;Choi, In-Seok;Kim, Hyun-Ji;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.165-173
    • /
    • 2013
  • This study was the estimation of the dose distribution for proton, prompt gamma rays and proton induced neutron particles, in case of exposing the proton beam to polymer gel dosimeter and water phantom. The polymer gel dosimeter was compositeness material of Gelatin, Methacrylic acid, Hydroquinone, Tetrakis and Distilled water. The density of gel dosimeter was $1.04g/cm^3$ which was similar to water. The 72, 116 and 140 MeV proton beams were used in the simulation. Proton beam interacted with the nuclei of the phantom and the nuclei in excited states emitted prompt gamma rays and proton induced neutron particles during the process of de-excitation. The proton particles, prompt gamma rays, proton induced neutron particles were detected by polymer gel dosimeter and water phantom, respectively. The gap of the axis for gel was 2 mm. The Bragg-peak for proton particles in gel dosimeter was similar to water phantom. The dose distribution for proton and prompt gamma rays in gel dosimeter and water phantom was approximately identical in case of 72, 116 and 140 MeV for proton beam. However, in case of proton induced neutron particles for 72, 116 and 140 MeV proton beam, particles were not detected in gel dosimeter, while the Water phantom absorbed neutron particles. Considering the resulting data, gel dosimeter which was developed in the normoxic state attentively detected the dose distribution for proton beam exposure except proton induced neutron particles.

The Study on the Head and Neck Phantom for Quality Assurance of Intensity Modulated Radiotherapy (세기변조방사선치료의 정도관리를 위한 두경부 팬톰 제작에 관한 연구)

  • Shin Dongho;Park Sung-Yong;Kim Joo Young;Lee Se Byeong;Cho Jung Keun;Kim Dae Yong;Cho Kwan Ho
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.39-46
    • /
    • 2005
  • For the QA of IMRT treatment of head and neck cancer by using M3 (BrainLAB Inc. Germany), it is not easy to measure delivery dose exactly because the dose attenuation appears by the couch according to the position of table and gantry. In order to solve this problem, we fabricated head and neck phantom which would be implemented on the couch mount of Brain Lab Inc. We investigated dose attenuation by the couch and found the difference of dose distribution by the couch, in the applying this phantom to the clinic. After measurement, we found that point dose attenuation was 35% at maximum and dose difference was 5.4% for a point dose measurement of actual patient quality assurance plan.

  • PDF