• Title/Summary/Keyword: 방사선오염

Search Result 321, Processing Time 0.021 seconds

Conceptual Design and Development of an Automatic Classification System According to Radioactive Contamination Level Measurement and Contamination of Radioactive Metal Waste (방사성 금속폐기물의 방사능 오염도 측정 및 오염 여부에 따른 자동 분류 시스템 개념설계 및 개발)

  • Sun Beom Kwon;Bo Gil Kim;Jeong Min Yeom;Gyeong Mo Lee;Hong Yeon Lee;Sang Jun Han
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2023
  • Waste generated during the dismantling of nuclear power plants is not only diverse in types such as metal, concrete, soil, but also in a large amount, requiring systematic and efficient management. It is very important to quickly and accurately measure radioactive contamination of wastes generated simultaneously at the decommissioning site, classify them by level, and make decisions so that they can be disposed of in accordance with related laws and regulations. In this paper, for the technical and economic aspects of recycling of radioactive metal waste generated during the dismantling of nuclear power plants, we propose a management system that can measure the radioactive contamination by shape of metal waste at the decommissioning site and automatically classify it according to the presence or absence of contamination. Accordingly, a system for collecting information on metal samples such as weight measurement and shape acquisition of metal waste, measurement of radioactive contamination and identification of nuclides, and an automatic classification system according to radioactivity measurement results were described.

Decontamination of Poultry Feeds by Gamma Irradiation (감마선 조사에 의한 가금용 사료의 살균)

  • Byun, Myung-Woo;Cho, Han-Ok;Lee, Jae-Won;Kwon, Joong-Ho;Kim, Young-Bae
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.403-408
    • /
    • 1987
  • The effects of gamma irradiation on microbiological and chemical qualities of four kinds of poultry feeds were investigated. The viable counts of total bacteria in the samples were $10^5\;to\;10^6/g$. They were reduced by 2 to 3 log cycles after 3 to 5 kGy irradiation, and were completely eliminated with irradiation of 7 kGy. Coliforms and enteric pathogens were contaminated in high levels in all samples, ranging from $1.2{\times}10^4\;to\;1.7{\times}10^5/g\;and\;4.0{\times}10\;to\;2.6{\times}10^3/g$, respectively, They were sterilized by 3 to 5 kGy irradiation. Fungi, ranging from $10^{2}\;to\;10^4/g$, mainly osmophiles were identified as Aspergillus and Penicillium. They were eliminated to a undetectable level by 5 to 10 kGy irradiation. Six kinds of species, including Aspergillus flavus, were potential mycotoxin producers. Chemical components, such as proximate compositions, and mineral contents were not affected by the gamma irradiation. However, TBA values and amino acid content seemed to be affected by gamma irradiation.

  • PDF

Consideration of Radioactive Contamination Materials Disposal (방사성오염물질 처분에 대한 고찰)

  • Im, Hyun-Jin;Kim, Tae-Yeob;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

  • PDF

기획 - 원자력 안전규제

  • Son, Myeong-Seon
    • Nuclear industry
    • /
    • v.36 no.3
    • /
    • pp.6-15
    • /
    • 2016
  • 우리나라가 급속한 성장을 이루는 과정에서 원자력은 이를 뒷받침하며 함께 성장해 왔다. 그러나 그 과정에서 안전보다 성과를 강조하다보니 안전을 경시하는 비정상적 환경이 조성되었다. 그 결과 숨겨져 있던 과거의 원전 비리가 수면 위에 드러났고, 같은 시기에 후쿠시마 사고로 인한 오염수 유출과 전력난까지 발생하면서 국민의 불안과 불신을 가중시켰다. 국민들은 정부가 불안감을 해소해 주고 원칙을 지키는 안전규제, 신뢰할 수 있는 안전규제를 마련할 것을 요구하고 있다. 원자력 안전규제의 독립성을 확보하기 위해 지난 2011년 설립된 원자력안전위원회는 출범 이후 새로운 안전규제 제도 시스템을 마련하는 데 총력을 기울여 왔다. 원전 비리 같은 비정상 관행을 근절하기 위해 공급자 검사 제도, 성능검증기관 관리 제도 등 새로운 규제 시스템이 마련되었고, 방사선 작업 종사자 보호 강화와 생활 주변 방사선 감시 효율성 제고를 위한 다양한 제도적 장치들도 구비되었다. 이외에도 원자력안전규제기금 설치, 원전 부지별로 설치된 원자력안전협의회 실효성 제고 등 소통과 협업을 위한 시스템을 정착시켰다. 그러나 단순히 제도와 시스템이 만들어졌다고 해서 원자력 안전이 저절로 확보되는 것은 아니다. 차고 다닐 옥의 종류가 바뀌면 걸음걸이도 바꾸어야 한다는 개옥개행(改玉改行)의 고사성어에서처럼 제도가 바뀌면 그에 따른 일하는 방식 문화가 달라져야만 변경된 제도 시스템이 완전히 정착될 수 있을 것이다. 이를 위해서는 규제기관의 노력도 중요하지만 무엇보다 필요한 것은 원전 및 방사선 관련 사업자, 이해 관계자 나아가 일반 국민들이 이러한 달라진 제도 시스템을 이해하고 이에 적극 협조해 나가는 것이다. 본 기획 기사는 그러한 취지에서 그간 원자력안전위원회가 안전규제를 공고히 하기 위해 추진해 왔던 주요 규제 정책, 제도들을 소개하는 데 주안점을 두었으며, 이를 통해 원전 및 방사선 관련 사업자와 일반 국민들의 이해를 바탕으로 새로운 제도 시스템이 조기에 성공적으로 정착될 수 있기를 희망한다.

  • PDF

A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter (전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Whole body counters (WBCs) are used to monitor radiation workers for internal contamination of radionuclides at domestic nuclear power plants (NPPs). A WBC is a scintillation detector using sodium iodide (NaI) and provides the identification of inhaled radionuclide and the measurement of its internal radioactivity in a short time. However, it is often possible to estimate external contamination as internal contamination due to radionuclides attached to the skin of radiation workers and this leads to an excessively conservative estimation of radioactive contamination. In this study, several experiments using a WBC and the Korean humanoid phantom were performed to suggest the more systematic method of discrimination between external and internal contamination. Furthermore, a WBC geometry experiment was conducted to suggest the optimal WBC geometry in consideration of deposited areas inside the body for dominant radionuclides at NPPs. The procedure of measurement and estimation of internal radioactivity for radiation workers at NPPs was improved on the basis of experimental results. Thus, it is expected to prevent from estimating internal exposure dose conservatively owing to the application of accurate whole body counting program to NPPs.

Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists (영상의학과 촬영실 장비와 방사선사의 손 오염의 세균학적 모니터링)

  • Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.329-335
    • /
    • 2008
  • Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  • PDF

Ultrasound Probe Contamination Classification using ATP Meter (ATP meter를 이용한 초음파 탐촉자의 오염도 분류)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.

Bacteriological Research for the Contamination of Equipment in Chest Radiography (영상의학과 흉부 엑스선 촬영 기기의 세균 오염도)

  • Choi, Seung Gu;Song, Woon Heung;Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.395-401
    • /
    • 2015
  • The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

A Study on the Natural Uranium Contamination Measuring Technology (천연우라늄 오염에 관한 방사선/능 측정기술 연구)

  • 정운수;홍상범;서범경;박진호;조용우;조성원;이정민
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.407-417
    • /
    • 2004
  • This study is to verify radiation detection method by using $\alpha$-spectroscopy and ${\gamma}$-spectroscopy for concretes and components which will be generated during the decommissioning of the uranium conversion plant. Components and inside walls of the building were contaminated with natural uranium materials. Some parts of the stainless steel pipes and concretes of the walls were sampled and analyzed their alpha and gamma activities respectively. Alpha and gamma activities are well matched each other in the range of high activity region to 0.01 Bq/g and gamma activities are over estimated comparing alpha activities corresponded in below 0.005 Bq/g region for the natural uranium of AUC sample. The $^{238}U$ originated from natural products of conversion process could be distinguished by measuring $^{214}Pb$ or $^{214}Bi$ and $^{234}Th$ or $^{234m}Pa$. Uranium contaminations mainly are in the wall surface of the plant. Decontamination process of generating wastes which can be reached tp background level gamma activities measured by gamma spectroscopy can also be used to conservative assessment data.

  • PDF

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.