• Title/Summary/Keyword: 방사선구역

Search Result 133, Processing Time 0.024 seconds

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Osteoid Osteoma in Scaphoid - A Case Report - (주상골의 유골 골종 - 1례 보고 -)

  • Lee, Kwang-Suk;Woo, Kyoung-Jo;Park, Jong-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.240-243
    • /
    • 1995
  • Osteoid osteoma is a benign osteoblastic tumor composed of osteoid and atypical bone, with a loose, highly vascular fibrous marrow. The tumor has been reported in most of the bones of the body, but it is infrequently localized to the hand. The scaphoid is the carpal bone involved most frequently. Typically the lesions are painful and respond to aspirin. Roentgenologic finding of the central area of lucency surrounded by sclerotic bone often is diagnostic. Block excision with bone grafting is an acceptable method of treatment. We report a case of osteoid osteoma in scaphoid with a review of the literature.

  • PDF

Pulmonary Cystic Lymphangioma -A case report- (폐에 발생한 낭성림프관종 -1예 보고-)

  • Yoon, Yong-Han;Cho, Jung-Soo;Lee, Kyung-Hee;Kim, Lucia;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.872-874
    • /
    • 2006
  • Although pulmonary lymphangioma is very rare, it is usually discovered as cystic or cavitary or solitary pulmonary nodular shadow on radiological studies. The final diagnosis is usually made pathologically after surgical intervention. We report an unusual case of pulmonary cystic lymphangioma developed in the lingular segment of the left upper lobe which was diagnosed and treated by surgical resection.

Relative Dose Distribution in the Biological Irradiation Facility at TRIGE Mark-III Reactor

  • Kim, Byung-Sung;Ha, Chung-Woo;Lee, Chang-Kun
    • Nuclear Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.277-284
    • /
    • 1975
  • A result of measurement for the relative dose distribution of neutron gamma mixed radiation field in the biological irradiation facility installed at TRIGA Mark-III reactor is described. The relative dose distributions of neutron-gamma mixed radiation field in the biological exposure room have been experimentally determined using a thermoluminescent dosimeter. Presented herein in graphical forms are the experimental results obtained. It as observed that the region commonly having the characteristics of rather homogeneous horizontal and lateral dose distributions is confined to the area bounded by the two planes horizontally parallel to the beam direction with heights of about 40 cm and 130 cm, respectively, at distances beyond 100 cm from the segmentary surface of the aluminum pool liner projected into the the exposure room, while other areas show a steeper gradient in dosage, especially the places adjacent to the segment of the aluminum pool liner and near the inner po${\gamma}$lion of the concrete walls of the exposure room.

  • PDF

Plantar Pressure Distribution Characteristics of Hallux Valgus (엄지 발가락외반증환자의 발바닥 압력분포 특성)

  • 김영호;박시복;양길태;임송학;이강목;문무성
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.439-446
    • /
    • 1997
  • We undertook this study to determine the plantar pressure distribution characteristics of hallux valgus, major increasing foot disease. Twenty three valgus Patients were evaluated with clinical examinations, radiologic studies and dynamic plantar pressure distribution measurements. The present study also suggested a masking method for detailed analyses on plantar pressure distribution measurements. With higher grade of hallux valgus, pressure, contact area, and impulse on metartasus are significantly increased Pressure concentration is very important in foot diseases and an approximate plantar pressure distribution should be considered on any shoe design.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

전자부품의 냉각을 위한 자연대류 상관 관계식의 평가

  • 이재헌
    • Journal of the KSME
    • /
    • v.27 no.6
    • /
    • pp.504-514
    • /
    • 1987
  • 복잡한 전자부품의 조립시에 필요한 열적 디자인에 관한 정보는 오래전부터 실험을 통하여 얻어지고 있다. 실험적 데이터를 이용하여 무차원 파라미터로 표시된 실험결과는 꼭 같지는 않지만 현상적으로는 비슷한 상황에 응용될 수 있다. 여기서는 학술문헌에 나타나 있는 자연대류에 관한 실험적인 상관관계식들과 프레임에 수직으로 꽂혀있는 균일가열 전자회로기판의 모델에서 얻어진 무차원 자료들을 비교하고자 한다. 대부분의 자료들은 수정채널 Rayleigh수(Ra")가 15~100범위에 속하며, 이러한 범위는 부품이 조밀하게 배치된 기관이 서로 좁은 채널을 이루고 있으며, 동시에 상당한 전력을 소비하고 있는 경우에 해당한다. Wirt와 Stutzman, Bar-Cohen과 Rohsenow의 일반상관관계식은 AT'||'&'||'T Bell 연구소에서 개발된 전자기기를 이용하여 수집한 실험데이터를 잘 표현하고 있으며 10 < Ra" <1,000범위에서 추천될 수 있다. 두개의 유사한 상관관계식과 비교할 때 상당히 좋은 예측을 보였으며 또한 Sparrow와 Gregg의 연구결과와도 잘 일치하므로 Ra" < 10인 경우에 Aung의 완전발달층류의 채널유동방식, Ra" > 1,000인 경우에는 Aung등의 단일 수직평판 근사식이 추천될 수 있다. Coyne의 알고리즘에 의한 계산치는 10

  • PDF

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Consideration of Radioactive Contamination Materials Disposal (방사성오염물질 처분에 대한 고찰)

  • Im, Hyun-Jin;Kim, Tae-Yeob;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.128-132
    • /
    • 2010
  • Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

  • PDF