• Title/Summary/Keyword: 방사능측정기

Search Result 18, Processing Time 0.024 seconds

Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth (치아의 전베타 농도 및 감마선 방사능 평가)

  • Jeong, Hyunja;Kang, Hyun-Kyung;Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.261-265
    • /
    • 2014
  • The ${\gamma}$-ray concentration and gross-${\beta}$ activity by age group were measured in the teeth of males and females of the domestic residents. They were divided into 7 age groups from 10s to the age of 70s. The gross-${\beta}$ activity concentration was measured by using the Tennelec XLB measuring instrument filled with P10 gas (argon 90%, methane 10%). The ${\gamma}$-ray was measured through the ${\gamma}$-ray spectroscopic analytical method by using the high purity germanium (HPGe) radiation detector. The range of gross-${\beta}$ activity concentration was measured 0.089 to 0.32 Bq/kg in females and 0.13 to 0.26 Bq/kg in males. From the ${\gamma}$-ray spectroscopic analysis of the teeth, the natural radioactive isotopes of $^{40}K$, $^{208}Tl$, $^{228}Ac$ and $^{234}Th$ were detected and their measured ${\gamma}$-ray activity concentrations were found to be 20.7, 21.9, 3.88 and 5.24 Bq/kg, respectively.

The Analysis of radioactivity Concentration in drainage when using a radioactive Iodine (방사성옥소 사용 시 배수 중 방사능농도 분석)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • Purpose With regard to the use of radioiodine in domestic medical institution, the case of exceeding the allowance of nuclear safety Act about radioactive concentration in drainage was found. Through understanding the cause of exceeding case and analyzing radioactive concentration in drainage, evaluating the relationship of the public waters in surroundings and usefulness. Materials and Methods From November 1, 2014 to April 30th, 2015, the research is aiming at domestic twenty hospitals for six months. By using a HPGe gamma-ray spectrometer(Canberra DSA-1000) and GENIE-2000 Analysis software for comparative analysis, measuring a radioactive concentration of radioiodine in drainage. Consequently, we confirm the excess of radioactive concentration of radioiodine in seven medical institutions. Results Conducting a survey of twenty hospitals and average radioactive concentration of radioiodine in drainage appears $42,100Bq/m^3$. The features of domestic hospitals where show a high radioactive concentration are a number of medical treatment patient when using radioactive iodine and the absence of private rest room. During I-131 whole body scan, the pretreatment procedure of urinating is considered emission of residual Iodine. In public waters, the cause of exceeding detect on radioactive concentration in drainage suppose a diagnostic radioactive iodine. Conclusion We confirm the importance of enhanced education, providing a safety control instructions and installing a private rest rooms for patients who injected a low capacity radioiodine. Also, constructing institutional and legal management system is considered about the Emission management standard in drainage.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF

Induced Activity and Space Dose Distribution from Medical Linear Accelerator (의료용(醫療用) 선형가속기(線型加速器)에 의한 산난공간(散亂空間) 선량분포(線量分布)와 유도방사능(誘導放射能))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • It is important to measure and protect from the radiation space dose and induced activity at the high energy medical linear accelerator facilities. These are to consider the additional risk to patients undergoing treatment, machine operators and staff members. Measurements of the space dose distribution and induced radioactivity at the 18 MeV medical linear accelerator facility in the Yonsei Cancer Center. 1. Exposure space dose for 300 rads monitor doses of 18 MeV electron are measured as 50 mR at 1 meter from patients. 2. Exposure space dose for 300 rads monitor doses of 10 MV X-ray are detected as 350 mR at 1 meter from phantom. 3. Induced radioactivity by photonuclear reaction was measured as 0.65 mR/hr from collimater after 30 Gy(3,000 rads) irradiated. 4. Analyzing the decay curves and energy spectrum of induced radioactivity, detected a few materials to be activated by photoneutron reaction, $^{65}Cu({\gamma}{\cdot}n)\;^{64}Cu,\;^{186}W({\gamma}{\cdot}n)\;^{185}W,\;^{181}Ta({\gamma}{\cdot}n)\;^{180}Ta,\;^{199}Au({\gamma}{\cdot}n)\;^{198}Au$.

  • PDF

Investigation on the techniques of quality control for radiation counting systems (방사선 측정기의 품질관리 기법에 대한 고찰)

  • Song, Byoung-Chul;Kim, Young-Bok;Han, Sun-Ho;Oh, Se-Jin;Lee, Myung-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.414-420
    • /
    • 2011
  • In this study, radiation measurement system has been investigated to set up for the radioisotopes analysis in the radioactive waste samples after selecting the radiation counters of alpha beta and gamma nuclides. The counting efficiencies for alpha, beta and gamma measurement systems were calibrated. To obtain stability of the radiation detectors, quality control program has been established. Also, minimum detectable activities (MDAs) depending on the type of samples were calculated for increasing the confidence level for analytical result.

Quality Control of Dose Calibrator using 3D Printery (3D 프린터를 이용한 Dose Calibrator의 품질관리)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.307-312
    • /
    • 2021
  • In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

A Study on Far-infrared Radiation and Proliferation of Ocherous Cotton Quilt Fabrics (황토를 부착한 이불 면 원단의 원적외선 방출량 및 생균의 분리 동정 연구)

  • Lee, Ku Yeon;Lee, Hyung H.;Hahm, Suk Chan
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.71-77
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the far-infrared emissivity of patented ocher quilt cotton fabrics and to investigate the microorganisms that survived the washing of cotton fabrics up to 20 times. Methods: A 16S rRNA assay was performed using a far-infrared radiometer and a single colony in which microorganisms grew in nutrient media. Results: The far-infrared emissivity of ocher quilt was 0.902 (90.2%) at 5~20 ㎛ at 40℃, and the radiation energy was 3.63 × 102 w/m2. The number of viable cells was 2.0 × 102 cells/ml in ocher duvet cotton fabric, and no viable bacteria found in regular cotton fabric. The base sequence of 16S rRNA of B-2 strain isolated into single colonies was 1,419 bases, and the base sequence of strain A-4 was 1,284 bases. The base sequence of 16S rRNA of these two strains showed high homology with Bacillus spp. The B-2 bacteria showed high homology with 99.0% of the 16S rRNA sequence of B. aryabhattai EF114313 and 99.0% of the A-4 bacteria of B. bingmayongensis AKCS01000011. Consequently the colony strain B-2 finally identified as B. aryabhattai BJ-2 and A-4 as B. bingmayongensis BJ-4 strain. Concusions: Soil Bacillus strains survived in ocher quilt cotton fabric after 20 washing. The material can be useful because quilt cotton fabric emits a large amount of far-infrared and far-infrared radiation energy.