• 제목/요약/키워드: 발화 시험

Search Result 81, Processing Time 0.052 seconds

Development of Electro-Mechanical Ignition Safety Device (전기-기계식 점화안전장치 개발)

  • Jang, Seung-Gyo;Kang, Ho-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.332-335
    • /
    • 2011
  • Electro-Mechanical Ignition Safety Device(EMISD) for solid rocket motor is designed and manufactured. The EMISD utilizes a true rotary solenoid for arming mechanism and an electric squib(initiator) for generating ignition energy. In order to prove the ignition capability of the EMISD, 10-cc Closed Bomb Test(CBT) is performed, which measures the pressure built by high temperature and high pressure gas generated by operating EMISD.

  • PDF

Study on combustion characteristics of the Wood (Pinus rigida, Castanea sativa, Quercus variabilis and Zelkova serrala) grew up in Korea (한국에서 자란 목재(리기다 소나무, 밤나무, 굴참나무, 느티나무)의 연소특성에 관한 연구)

  • Shi, Nan;Jin, Eui;Oh, Jung-Kyoo;Chung, Yeong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.321-324
    • /
    • 2011
  • 건자재로서 나무 결함 중의 하나는 화재에 대한 취약성이다. 본 연구의 목적은 한국에서 자란 리기다 소나무, 밤나무, 굴참나무, 느티나무의 연소성질을 시험하는 것과 건자재로서의 사용에 대한 바람직한 특성을 알아내는 것이며 연소억제를 위해 실온에서 3종류의 암모늄염 즉, ammonium sulfate, monoammonium phosphate, 그리고 diammonium phosphate를 20 wt% 수용액에 각각 리기다 소나무를 함침시켜 건조시킨 후 재료의 난연성을 시험하였다. 콘칼로리미터(ISO 5660-1)를 이용하였고 분석 결과로는 열방출랑을 비롯하여, 가스방출량, 발화점 등을 측정하여 비교분석하였다.

  • PDF

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

A Study on the Assessment of Hazardous Properties of the Oxidizing Solids (산화성고체의 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Park, Chul-Woo;Song, Haak
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.9-16
    • /
    • 2009
  • Chemical products have had an favorable influence on our everyday life, and contributed very much to the development of human culture. According to the rapid change of industry and the development of scientific technique the using chemical products are increasing more and more. Chemical products can have any hazardous property such as flammability or explosiveness. There are occurring many accidents in the international trade due to the different classification and labelling of chemicals produced in various countries. The main purpose of this work is the development of global standard test methods for the chemicals, and the classification and labelling in building block approach by means of the basic technical data. Oxidizing solids, combustible solids, spontaneously combustible materials, water-prohibitive materials, flammable liquids, self-reactive materials and oxidizing liquids have been classification The first Experiment have tested Oxidizing solids of third five. The results have been classified according to the hazard material safety regulation and the UN regulation, and summarized in a data-base.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

Study of Analysis on Dielectric Strength of Vegetable Oil for Development of Eco-friendly Transmission Transformer (친환경 송전급 변압기 개발을 위한 식물성절연유 절연성능 분석 연구)

  • Kim, Yong-Han;Seok, Bok-Yeol;Lee, Chanjoo;Kang, Hyoungku;Kim, Joon-Yeon;Oh, Hoon;Kim, Dong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1195-1196
    • /
    • 2008
  • 최근, 친환경 물질이면서 광유에 비하여 발화점이 높은 식물성절연유에 대한 관심이 고조되고 있으며 식물성절연유변압기의 사용이 미주 등 해외시장에서 급격하게 증가되고 있다. 본 연구에서는 송전급 식물성절연유변압기 개발을 위하여 액체절연 매질의 고전압 시험법을 검토하고 전극 간 이격 거리에 따른 절연파괴 시험을 통하여 식물성절연유의 절연성능을 평가하였다. Weibull 분포와 전계해석을 이용하여 2% 절연파괴전압을 산출하고 전계분포를 계산하여 기존의 변압기 절연매질인 광유와 비교하였다. 본 연구 결과는 향후 식물성 절연유변압기 제작에 필요한 설계 자료로 활용될 것이다.

  • PDF

The Ignition Characteristics of Tree Branches, Barks, Living Leaves and Dead Leaves in Pinus Densiflora and Quercus Dentata (소나무와 떡갈나무의 주요 부위별 착화특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Sin, Young-Ju;Kim, Su-Young;Kim, Young-Tak;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.308-312
    • /
    • 2008
  • In this study, we have carried out test to examine the ignition characteristics, such as a relation of moisture content and combustibility, and ignition temperature using KRS-RG-9000 tester, of significant part of above trees which are representative species of Young Dong Province of Korea. After rainfall, the percentage of moisture content of living leaves and branches was between 52 and 70%. But it was just between 17 and 33% after 144 hours drying at normal temperature. For dead leaves, it was 10% lower than of first. There was a significant difference on ignition characteristics. The hazard of ignition is highest on dead leaves. The ignition temperature of barks and branches is higher so a retard time is long than of living and dead leaves at normal temperature.

  • PDF

Flammability and Thermal Stabilities of Heat Transfer Oils (열매체유의 인화성과 열안정성)

  • Lee, Keun-Won;Lee, Jung-Suk;Choi, Yi-Rac
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.82-87
    • /
    • 2011
  • Heat transfer oils are used in applications such as heating systems of chemical plant, refinery heat exchange systems, gas plant process, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistance to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignite easily when there is an ignition source. This paper discusses the flammability and thermal stabilities of new and used oils. The flammability of the oils are assessed by measuring changes in flash point and auto ignition temperature. The thermal stability of oils are evaluated by the thermal screening unit ($TS^u$) and the differential scanning calorimeter (DSC). From the experimental results, it is suggested to give fire hazard characteristics to safe precautions for the proper use and treatment of heat transfer oils.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.