• Title/Summary/Keyword: 발전소 온배수

Search Result 82, Processing Time 0.026 seconds

A Review on Conception of Policy for Production of Imported Tropical and Temperate Fresh Fruits Using Hot Waste Water from Power Plant (발전소 온배수를 활용한 온·열대 신선과일 수입대체 정책 방안)

  • Kim, Yean-Jung;Park, Jiyun;Kim, Bae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.48-53
    • /
    • 2017
  • One of the policies of the Ministry of Agriculture, Forestry and Livestock Food and Livestock aims to export $10 billion worth of products. Although it was not easy to achieve the export goal of $ 6.5 billion in 2016, the policy should be pursued continuously. Accordingly, a facility modernization project and high-tech greenhouse project are being implemented to facilitate exports. Moreover, it is possible to consider substitution of imports in the policy shift. Imports of temperate and tropical fresh fruits totaled 1.2 trillion won in 2016. Accordingly, identification of alternatives to tropical and temperate fresh fruit imports will enable farm income to increase and the fresh fruit industry to grow. The major obstacle to tropical fruit production in Korea is high heating costs. However, Jeju Island apple mango farmers found that using non-taxable kerosene and hot water from power plants could reduce heating costs by 42.5%. Indeed, using hot wastewater can reduce heating costs by more than 40%. To improve competition with imported fruits, farmers can change their heating systems using financial support plans (e.g., 20% government subsidies, 20% loans, 30% subsidies from local governments). The income effect and import substitution effect of fruit tree farmers should be carefully analyzed in the future and the study will be closed to discuss the policy direction.

Flow Analysis of Thermal Discharge Channel due to Development of Hydropower (발전소 해수방수로의 수력개발에 따른 수리특성 분석)

  • Kim Ji-Young;Lee Dae-Soo;Kang Keum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.498-501
    • /
    • 2005
  • 삼천포 등 국내 대형 화력발전단지에서 냉각수로 사용되고 방류되는 해수는 약 150 cms로 (100 MWe당 약 5 cms) 약 3,000 kW 이상의 수력에너지를 보유하고 있으나, 현재 활용되지 못하고 그대로 해양으로 방류되고 있어 이 수력에너지의 개발을 추진하고 있다 온배수를 이용한 수력 개발시에는 기존 발전소의 배수로를 변경하여 이용하는 것으로 기존 발전소에 미치는 영향을 최소화하는 것이 중요하다. 본 검토에서는 삼천포화력에 댐식 수력발전소를 건설할 경우 기존 배수로의 수리특성 변화를 3차원 유동해석 프로그램인 FLOW-3D를 이용하여 해석한 결과를 소개하였다. 수치해석 결과를 이용하여 수력에너지의 최적 개발을 도모하였고, 다양한 운전조건을 설계에 반영할 수 있었다.

  • PDF

Hematological Characteristics of Olive Flounder (Paralichthys olivaceus) in Culture Farm Influenced by Heated Effluent Water from a Power Plant in Summer (여름철 온배수 수역에 인접한 양식장 넙치(Paralichthys olivaceus)의 혈액 성상)

  • Chang, Young-Jin;Hur, Jun-Wook;Chin, Pyung
    • Journal of Aquaculture
    • /
    • v.15 no.4
    • /
    • pp.267-273
    • /
    • 2002
  • Effect of heated water from a power plant in summer on hematological characteristics of flounder (Paralichthys olivaceus) were investigated. Hematocrit level fluctuated between 15.7 and 16.3% in control farm, but it significantly increased to 17.7% in the high-WT farm. The corresponding values for hemoglobin concentration were 9.9~18.0 $g/㎗$ for the control farm and 6.2~19.4 $g/㎗$ for the exposed farm. The plasma cortisol remained between 0.6 and 2.8 ng/$ml$ in the former but significantly decreased 317.1 to 3.3 ng/$ml$ in the later. The plasma glucose also decreased from 36.5~46.0 to 23.5~36.5 mg/$dl$. Plasma osmolality decreased from 551.5~597.0 to 391.0~466.5 mOsm/kg.

A Numerical Analysis of Thermal Discharge using k-1 Turbulence Closure (k-1 난류모델을 이용한 온배수 수치해석)

  • 최홍식
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.146-151
    • /
    • 1995
  • 원자력, 화력발전소 및 임해공업시설로부터 방출되는 냉각용 온수는 하천 또는 연안일대의 수계환경에 전반적인 수중온도의 상승과 가동 중단시 갑작스러운 수온 저하 등의 열균형 파괴를 가져온다. 따라서 여러가지 형태의 주위수에 영향을 받는 온배수의 이동 및 확산에 대한 정성, 정량적 예측을 위한 수치모델의 개발은 환경관리 및 생태계 보전 측면에서 매우 중요하다. (중략)

  • PDF

A Study on Hydro Energy Development of Discharged Cooling Water at the Power Plant (발전소 온배수의 수력에너지 개발에 관한 연구)

  • Kang, K.S.;Lee, D.S.;Kim, J.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.813-818
    • /
    • 2005
  • Cooling seawater of thermal power plant which amounts about 5 cms per 100 MWe has hydro energy of about 3,000 kW at the thermal power plant complex, but this useful hydro energy has not been developed. Therefore, the feasibility study on hydro energy development of three power plants located in the southern and western coast of Korea was performed. Three target power plants are Samcheonpo, Boryeong and Hadong thermal power plant. The design head to discharge cooling water by gravity and the head caused by tidal level in the southwestern coastal area, could be used for the production of electric power. The various alternatives were studied and technical feasibility and economical efficiency were clearly proved.

  • PDF

Thermal Effluent Diffusion and Flow Characteristics using the TGPS Buoy (TGPS 부이를 이용한 온배수 확산과 흐름 특성)

  • 박일흠;이연규;최정민
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.614-617
    • /
    • 2000
  • To get the maximum diffusion boundary of thermal effluent of Youngkwang Nuclear Power Plant, paths of TGPS Buoy and temperatures of surface water are obtained to 4 times at spring tide during 1 year. According to the paths of TGPS Buoy, the flumes of thermal effluent are moved about 12km from outlet to SW or WSW direction. After 3∼4 times of tidal period the waters are reached to Chilsan Island because the ebb flow is more predominant than the flood flow in this area. At the spring and fall season, a sudden drop of surface water temperature is detected around 5km radius from the outlet. At the summer season, it is measured about 10km. On the other hand the flumes are continuously cooled down by the atmosphere condition at winter season.

  • PDF

Development of Industrialization Model of IoT-Based Smart Farm (스마트 수직구조 양식장의 원격제어 App 개발)

  • Kim, Yu-Hwan;Kim, Byeong-Jun;Shin, Kyoo-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.343-345
    • /
    • 2018
  • 전력 발전사들은 해안을 중심으로 운영되고 있는데, 이는 발전하는 과정에서 회전기기 터빈과 발전기 열을 냉각시키기 위해 해수를 사용한 후, 발생한 온배수는 해안으로 방출되고 있다. 양식장에는 수온 관리를 하는데 큰 비용이 발생하기 때문에 수열에너지를 공급하는데는 경제적으로 매우 중요하다. 따라서 효율적인 스마트 양식장을 운용하기 위해서는 발전소에서 폐수로 방출되는 온배수 에너지원을 재생에너지로 활용하여 이 열을 저장하고 양식수조에 공급하는 온배수 히트펌프의 수온 제어시스템과 양식수조의 최적화 설계를 위하여 새로운 형태의 육상수조 양식구조와 수질과 수온을 제어하는 IoT(Internet of Things)기반의 스마트 양식장이 필요하다.

Analysis of Sea Surface Temperature Distribution Around Uljin Nuclear Power Station Using Time Series Landsat Satellite Images (시계열 Landsat 위성영상을 활용한 울진 원자력발전소 주변 해수온도 분포분석)

  • Choi, Seung-Pil;Yook, Woon-Soo;Hong, Sung-Chang;Song, Yeong-Sun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.51-57
    • /
    • 2007
  • In this study, We analyzed change of sea surface temperature due to cooling water around nuclear power station. Study area is around of Uljin nuclear power station, which is relatively large power station. There are many problems in monitering environmental change around of nuclear power station, because area is relatively large. We used Landsat 5, 7 Imagery which are useful in temperature analysis and can be easily obtained. After we georeferenced Landsat Imagery, radiance and sea surface temperature were calculated. As a result, As we compared sea surface temperature of surrounding area of nuclear power station with same area located 3 km east, there are $2.049^{\circ}C$ temperature difference.

  • PDF

A Tracing Survey of Hot Waste Spread from Nuclear Power Station by Means of Landsat TM Images (Landsat TM 영상에 의한 원자력 발전소로부터의 온배수 확산의 추적조사)

  • 최승필;양인태
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.231-236
    • /
    • 1997
  • Observation for hot water spread has been carried out by such activites as sampling of water with ship, etc, until now It was required further to have new probe methodologies in such issues as simultaneity, great-spheric nature, and economics due to many hindering ele- ments such as spread speed of hot waste water, weather conditions, cost and expenses, scope and location determinations. However, it was believed that satellite could be utilized to monitor spread of water temperature and spread level in more quick and correct way than existing one, because it would be possible to supervise and detect marine environment within significantly short period if analyzed by means of satellite images. Therefore, this study is taken into account to flow and spread conditions of hot waste water, survey of water temperature, by means of satellite images.

  • PDF