• Title/Summary/Keyword: 발열 특성

Search Result 1,073, Processing Time 0.025 seconds

Generation of Hydration Heat of the Concrete Combined Coarse Particle Cement and Blast Furnace Slag (조분 시멘트와 고로슬래그를 조합 사용한 콘크리트의 수화발열 특성)

  • Noh, Sang-Kyun;Baek, Dae-Hyun;Jang, Duk-Bae;Kim, Young-Pil;Cha, Wan-Ho;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.61-65
    • /
    • 2008
  • This study, having combined and displaced blast furnace slag("BS" hereinafter) known as admixture material that delays hydration reaction with coarse particle cement("CC" hereinafter) collected in particle classification method during ordinary portland cement("OPC" hereinafter), reviewed the hydration heat characteristics affecting the concrete. To reduce hydration heat, the study plain-mixed which used 100% OPC for W/B 50% level 1, displaced CC at level 3 of 25%, 50% and 75% for OPC, and by displacing BS with admixture material at level 5 of 0%, 20%, 40%, 60% and 80% for cement(OPC+CC), experimented totally 16 batches. As a result of experiment, in the case of flow, the more CC displacement rate increased, the more it tended to decrease, and the more BS displacement rate increased, the more it decreased. Also, as for simple adiabatic temperature rise by the CC and BS displacement rates, it decreased as displacement rate increased, and particularly in the case of displaced BS of 80%, It showed temperature reduction effect of about 63% companing with plain. Compressive strength decreased in proportion to displacement rate, however strength reduction increment was shown to decrease with age progress.

  • PDF

Study on the size spectrum and morphology of soot particles in a compartment fire (구획화재에서 매연입자의 시간에 따른 입경별 농도분포 및 형상 변화에 관한 연구)

  • Goo, Jae-Hark
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.258-261
    • /
    • 2011
  • 실내에서 화재가 발생한 경우에 매연의 크기분포 및 형상(morphology) 변화 특성은 경보장치의 작동 및 흡입에 의한 인체피해 등과 관련되어 중요한 연구 분야이다. 이와 관련하여 많은 연구가 이루어져 왔으나 실험에 의한 연구는 각 연구마다 결과치가 정량적 또는 정성적 측면에서 많은 편차를 보이고 있고, 이론적인 연구는 몇몇 특정 조건에 대하여 제한적으로 이루어져 있어서, 실재 구획화재에 적용하는 데는 어려움이 있다. 이 연구에서는 구획화재에 대하여 발열속도이력(history of heat release rate) 및 매연발생률(soot yield) 등에 따른 매연입자의 크기분포 및 형상 변화 해석을 위한 방법을 개발하였으며, 이를 유럽표준시험화재(EN54 Part7)에 규정된 폴리우레탄폼화재(TF4)에 대하여 시험 적용하였다. 이 방법에서는 입자의 크기분포방정식(dynamic equation for the discrete-size spectrum)을 푸는데 있어서 계산시간을 줄이기 위하여 결절방법(nodal method)을 도입하였으며, 또한 실재 화재에서의 매연입자의 성장에 따른 입경범위에 맞추기 위하여 분자운동영역(free molecular region)과 연속영역(continuum region)을 포괄하는 입자크기에 적용되는 충돌빈도함수(collision frequency function)를 사용하였다.

  • PDF

Recycling of Sound Insulation Headliner Waste Material (흡음재 폐기물의 재활용 방안)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3089-3095
    • /
    • 2013
  • The headliner was made of polyurethane(PU) and glass fiber(GF) composite materials are widely used as a sound insulation material. A large amount of waste materials occurs as a by-product in the headliner manufacturing process. In order to efficiently reuse the headliner waste materials, separation process of the components are very necessary. According to the results of thermal analysis, weight loss showed increase in the order polyurethane foam> non-foaming polyurethane> non-woven fabric> 1st layer> glass fiber in the range of up to $400^{\circ}C$. Analysis of the DSC characteristics, HDPE, LLDPE, PP, and Master Batch by adding additives the wasted scrap. As a result, except for the PP, there was no exothermic transition due to the crystallization.

A Study on Combustion Characteristics of Purverized Fuel Made from Food Waste (음식물쓰레기로부터 제조한 분체연료 연소특성)

  • Son, Hyun-Suk;Park, Yung-Sung;Yun, Jong-Deuk;Lee, Ho-Nam;Lee, Seung-Hoon;Kim, Sang-Guk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.149-152
    • /
    • 2008
  • Three properties of food waste are water 80%, ash 3%, volatile matter 17%. When food waste goes through treatment process such as removal of foreign substances, removal of water as well as sodium, dryness, and pulverization, it transforms into 4,000Kcal/kg purverized fuel if moisture content is below 13%. Fuel ratio(fixed carbon/volatile matter) of purverized fuel is low compared with bituminuous coal. Ignition temperature measured by thermogravimetry analyzer is about $460^{\circ}C$. Combustion test of purverized fuel have been performed using energy recovery facility which include storage tank of dewatered cake, dryer, hammer mill, combuster including burner, boiler, flue gas treatment equipment. When 160-180 kg/hr of fuel is steadily supplied to burner for 3 hours, combueter temperature reaches about $1000^{\circ}C$ and CO is 77-103ppm at 1.55 excess air ratio and SOx and Cl are under 2ppm and 1ppm, respectively. This experiment demonstrate that purverized fuel made from food waste could be an alternative clean energy for high oil price era

  • PDF

Effects of Sintering Conditions and Additives on the Properties of Sintered MoSi$_2$Powders Prepared by Self-propagating High-Temperature Synthesies (자전고온합성법으로 제조한 이규화몰리브덴 발열체의 소결특성에 미치는 소결조건 및 첨가물의 영향)

  • Sim, Geon-Ju;Jang, Dae-Gyu;Seo, Chang-Yeol;Kim, Un-Baek
    • Korean Journal of Materials Research
    • /
    • v.5 no.8
    • /
    • pp.921-928
    • /
    • 1995
  • MoSi$_2$heating elements were fabricated using MoSi$_2$, powder prepared by SHS. Their apparent density, electrical resistivity, bending strength and victors hardness were measured as a function of sintering temperature, time and the amount of ceramic additives. The additives were A1$_2$O$_3$, SiO$_2$and bentonite which were added as a plastisizer. The electrical resistivity of MoSi$_2$decreased with the increase in the apparent density as expected. It decreased when the additives were added and the increase was the largest for the case of SiO$_2$. The bending strength and hardness decreased when the grain size becomes larger which is opposite to the expectation from the Hall-Petch type relation. Instead, they showed inverse proportionality with the volume fraction of pores probably in an exponential manner. The strength and hardness also decreased with the additives.

  • PDF

Effects of Emulsifier on the Thermal Behaviour in Palm Oil (유화제의 첨가가 팜유의 열 특성에 미치는 영향)

  • Chang, Young-Sang;Yi, Young-Soo;Kang, Woo-Suk;Shin, Zae-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.857-862
    • /
    • 1989
  • Palm oil was crystallized and melted in the differential scanning calorimeter (DSC) in the presence and the absence of sucrose fatty acid ester (SE) at the different scanning rate. In the presence of SE, the crystallization temperature of palm oil was lowered, because SE inhibited the formation of mother crystal at the initial cooling stage The melting curves of SE added palm oil changed irregularly in the ${\alpha}-form$ transition and fusion entropy. It was that the presence of SE affected the molecular diffusion in palm oil.

  • PDF

Characterization of a TSV sputtering equipment by numerical modeling (수치 모델을 이용한 TSV 스퍼터링 장비의 특성 해석)

  • Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.46-46
    • /
    • 2018
  • 메모리 소자의 수요가 데스크톱 컴퓨터의 정체와 모바일 기기의 폭발적인 증가로 NAND flash 메모리의 고집적화로 이어져서 3차원 집적 기술의 고도화가 중요한 요소가 되고 있다. 1 mm 정도의 얇은 웨이퍼 상에 만들어지는 메모리 소자는 실제 두께는 몇 마이크로미터 되지 않는다. 수직방향으로 여러 장의 웨이퍼를 연결하면 폭 방향으로 이미 거의 한계에 도달해있는 크기 축소(shrinking) 기술에 의지 하지 않고서도 메모리 소자의 용량을 증대 시킬 수 있다. CPU, AP등의 논리 연산 소자의 경우에는 발열 문제로 3D stacking 기술의 구현이 쉽지 않지만 메모리 소자의 경우에는 저 전력화를 통해서 실용화가 시작되었다. 스마트폰, 휴대용 보조 저장 매체(USB memory, SSD)등에 수 십 GB의 용량이 보편적인 현재, FEOL, BEOL 기술을 모두 가지고 있는 국내의 반도체 소자 업체들은 자연스럽게 TSV 기술과 이에 필요한 장비의 개발에 관심을 가지게 되었다. 특히 이 중 TSV용 스퍼터링 장치는 transistor의 main contact 공정에 전 세계 시장의 90% 이상을 점유하고 있는 글로벌 업체의 경우에도 완전히 만족스러운 장비를 공급하지는 못하고 있는 상태여서 연구 개발의 적절한 시기이다. 기본 개념은 일반적인 마그네트론 스퍼터링이 중성 입자를 타겟 표면에서 발생시키는데 이를 다시 추가적인 전력 공급으로 전자 - 중성 충돌로 인한 이온화 과정을 추가하고 여기서 발생된 타겟 이온들을 웨이퍼의 표면에 최대한 수직 방향으로 입사시키려는 노력이 핵심이다. 본 발표에서는 고전력 이온화 스퍼터링 시스템의 자기장 해석, 냉각 효율 해석, 멀티 모듈 회전 자석 음극에 대한 동역학적 분석 결과를 발표한다. 그림1에는 이중 회전 모듈에 대한 다물체 동역학 해석을 Adams s/w package로 해석하기 위하여 작성한 모델이고 그림2는 180도 회전한 서브 모듈의 위상이 음극 냉각에 미치는 효과를 CFD-ACE+로 유동 해석한 결과를 나타내고 있다.

  • PDF

Properties of St/BA Modified Cellular Lightweight Concrete as Sandwich Panel Core (샌드위치패널심재로 활용한 St/BA 개질 다공성 경량 콘크리트의 특성)

  • 강내민;노정식;도정윤;문경주;소양섭
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.31-34
    • /
    • 2003
  • Sandwich panel is composed of the facing sheets which support the external load, the cellular core with the low thermal conductivity and the adhesive agent to bond them. The cellular core was produced by binding lightweight cellular aggregates with cement and two types of acrylic base St/BA emulsion were added with a view to improving the workability ion due to high absorption of light weight aggregate and to develope more strength, respectively. This investigation is to comprehend the effect of the addition of two types of St/BA on thermal conductivity, calorific value and exhaustion content of noxious gas in addition re compressive and flexural strength. Flexural strength of the specimen made with St/BA-2 ranged 20kgf/cm2 to 25kgf/cm2 and was about 50% to 100% as high as that of the non-fiber specimen. Thermal conductivity was recorded from 2.0 to 3.0 kcal/mh$^{\circ}C$ and calorific value of St/BA modified specimen was much lower than that of commercial sandwich panel core of EPS and urethane. Careful caution has to be taken because generation of noxious gas such as CO, NO and SO2 tend to increase with addition of polymer cement ratio.

  • PDF

Carbon Monoxide Consumption in Digestate and its Potential Applications (혐기성 소화액에서 일산화탄소 소비특성 분석과 그 활용 방안)

  • Hong, Seong-Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • Acetogen과 같은 일부 혐기성미생물은 소위 acetyl-CoA 경로에 의해 아세트산, 에탄올, 그리고 몇 가지 생화학 물질을 생산한다. 이 경로에서는 일산화탄소를 기질로 이용할 수 있다. 일산화탄소 이외에 수소가 이용될 수 있다. 즉 이들 미생물은 독립영양생물로서 이산화탄소와 태양광에너지를 이용하는 녹색식물과 비유될 수 있으며, 일산화탄소는 탄소원으로서 동시에 에너지원으로서 이용된다. 본 연구에서는 혐기성 소화액 중 아세트산을 생성하는 미생물이 존재한다고 가정하고, 일산화탄소와 수소가 주 가연성분인 합성가스를 공급하면 추가의 메탄이 생성가능성을 평가하였다. 혐기성 소화과정에서 발생되는 메탄은 주로 아세트산으로부터 만들어지므로 일산화탄소를 공급하는 경우 추가로 메탄이 생성될 것으로 추측할 수 있기 때문이다. 이를 확인하기 위하여 현재 운영중인 바이오가스 생산 설비로부터 얻은 혐기성 소화액을 생물반응조에 넣은 후, 합성가스를 순환-공급하여 가스 생산량의 변화 및 조성을 분석하였다. 질소가스를 공급한 대조구와는 달리 일산화탄소 또는 합성가스를 공급한 경우에는 메탄가스가 생산되는 것을 확인하였다. 질소가스를 공급한 대조구와는 달리 일산화탄소 또는 합성가스를 공급한 경우에는 메탄가스가 생산되는 것을 확인하였다. 일산화탄소만을 공급했을 때에는 이산화탄소의 생성으로 가스 생산량이 증가하였으나, 수소가 포함된 합성가스를 공급하였을 때에는 이산화탄소가 탄소원이로 소비되어 가스 저장도 내의 가스량이 감소하는 것을 확인할 수 있었다. 가스화공정에 으해 얻어지는 합성가스는 온도와 가스 조성을 고러할 때, 바이오가스 생산을 위한 혐기성 소화조와 연계하면 소화조의 가온에 필요한 열을 공급할 수 있고 바이오가스 중 이산화탄소 농도를 낮추어 발열량을 개선할 수 있을 것으로 판단된다.

Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations (선풍기의 운전 상황별 발열특성 및 전류신호 검출)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.