• Title/Summary/Keyword: 발열 특성

Search Result 1,073, Processing Time 0.027 seconds

Fuel Properities of Spent Coffee Bean by Torrefaction (반탄화에 의한 커피박 연료특성)

  • Oh, Dohgun;Kim, Yonghyun;Son, Hong-Seok
    • New & Renewable Energy
    • /
    • v.9 no.3
    • /
    • pp.29-35
    • /
    • 2013
  • This research analyzed the fuel characteristic change of spent coffee bean by torrefaction. The calorific value was increased from 4,974 kcal/kg to 6,075 kcal/kg ($260^{\circ}C$, 30min), 6,452 kcal/kg ($270^{\circ}C$, 30min), 6,823 kcal/kg ($280^{\circ}C$, 30min), 6,970 kcal/kg ($260^{\circ}C$, 30min). The highest energy yield was obtained when the spent coffee bean were torrefied on the condition of $280^{\circ}C$, 30min. The moisture absorption rate was decreased from 5.12% to 2.76% when the spent coffee bean were torrefied on the condition of $290^{\circ}C$, 30min. Lignin was increased from 11.33% to 14.39% on the condition of $260^{\circ}C$ 30min. But it did not preferability to torrefy spent coffee bean at temperature of more than $270^{\circ}C$ because lignin decreases to the level that is hard to make pellet.

Fabrication of Micro-Heatsink using Nanotemplate (나노 템플레이트를 이용한 마이크로 히트 싱크)

  • 함은주;손원일;홍재민
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • The semiconductor chips or electronic components generate heat, which causes malfunction of the parts when it was not cooled properly. Bulky heat sink and cooling fan are used to get rid of the heat. However, with this bulky system, it is hard to integrate the electronics system in a small scale. The cooling efficiency of the system depends on the surface area of the heat sink, thermal conductivity of the material and the method of integration. In order to develop a novel cooling system, a micro-heatsink with a large surface area while retaining small volume was fabricated by electroless deposition of gold/copper inside a Track-etched membrane. The structure of the micro-heatsink was investigated using SEM or optical microscope. It was also found that the micro-heatsink is more efficient than a flat copper plate.

  • PDF

Analysis of Thermal Characteristics for Components of Electrical Door System in Electric Multiple Unit (전동차 전기식 도어시스템의 구성부품에 대한 발열 특성분석)

  • Lee, Bon Hyung;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.18-24
    • /
    • 2020
  • This research conducted an the failure analysis was performed based on the failure and operation data for Seven years using the Reliability, Availability, Maintainability, and Safety(RAMS) constructed at the operation stage after the opening of the D urban railway. therefore, the risk priority was selected for failure frequency component within the door system that showed high failure. Finally, the goal was to suggest ways to improve the door system. For this purpose, the analysis of thermal characteristics of failed components such as Door Control Unit(DCU) in the door system based on the Seven-year failure analysis data of RAMS was performed. These results were applied to the main component exchange cycle of the door unit, the mean time between failure(MTBF) and mean kilometer between failure(MKBF) values of RAMS increased by 26% in 2017-2018 when the improvement measures were taken, and the MTBF value of DCU was 300,000 hours, which was a 57% improvement in reliability. The results of this thesis identify potential enhancements in reliability and improvements in maintenance of the door system that, if implemented, would contribute to train safety and reduce instances of failure in the future.

Experimental Study of Gasification Characteristics of Low-rank Liquid Fuel and Producer gas Generation in a Fluidized Bed Reactor (유동층 반응기에서 액상의 저급 연료 가스화 특성 실험 및 프로듀서 가스 생산을 위한 연구)

  • Kim, Youngdoo;Jeong, Soohwa;Jung, Jaeyong;Yang, Won;Lee, Uendo
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.25-28
    • /
    • 2014
  • In this study, waste cooking oil was gasified in a fluidized bed reactor. The main objective of this study was to produce clean producer gas for power generation engine. As a result, heating value of producer gas is suitable for engine operation and tar content in producer gas was satisfied after use of activated carbon filter. Results from a lab scale experiment and a preliminary results from a pilot scale experiment will be presented.

  • PDF

Characteristics of Cooling for the Adjacent Double Micro-Porous Coated Surfaces in PE5060 (마이크로다공성 코팅된 인접 복수 발열체에 대한 PF5060의 냉각 특성)

  • Kim Tae-Gyun;Kim Yoon-Ho;Lee Kyu-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.646-655
    • /
    • 2006
  • The present research is an experimental study on characteristics of cooling behavior for the adjacent copper blocks with surface roughness or micro-porous coated surface. The experiments were carried out at saturation state or within subcooled states of PF5060. The effects of heater orientation and the intervals between heating surfaces or substrates were investigated under various heat flux conditions. The boiling performance of copper block with micro-porous coated surface was better than that of copper block with surface roughness. It is understood that the bubble sweeping enhances boiling performance for the heaters with inclinations of $\theta=45^{\circ}\;and\;\theta=90^{\circ}$, where as the bubble flattening decreases boiling performance for the heaters with inclinations of $\theta=135^{\circ}\;and\;\theta=180^{\circ}$. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping. It is also found that boiling performance decreases in the case of adjacent double heaters with only 0.2cm substrate interval.

Gradational Double Annealing Process for Improvement of Thermal Characteristics of NiCr Thin Films (NiCr 박막의 발열 특성 개선을 위한 순차적 이중 열처리 방법 연구)

  • Kwon, Yong;Noh, Whyo-Sup;Kim, Nam-Hoon;Cho, Dong-You;Park, Jinseong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.714-719
    • /
    • 2005
  • NiCr thin film was deposited by DC magnetron sputtering on $A;_2O_3$/Si substrate with NiCr (80:20) alloy target. NiCr thin films were annealed at $300^{\circ}C,\;400^{\circ}C,\;500^{\circ}C,\;600^{\circ}C,\;and\;700^{\circ}C$ for 6 hr in $H_2$ after annealing at $500^{\circ}C$ for 6hr in air atmosphere, respectively. To analyze NiCr thin film properties, the changes of its micro structure were Investigated through field emission scanning electron microscope (FESEM). X-ray photoelectron spectroscopy (XPS) was used to analyze a surface of NiCr thin film. Resistance of NiCr thin film was measured by 4-point probe technique. The generated heats were measured by infrared thermometer through the application of DC voltage (5 V/l2 V). NiCr thin film treated by gradational double annealing process had uniform and small grains. Maximum temperature generated heat by NiCr micro heater was $173^{\circ}C$. We expect that our results will be a useful reference in the realization of NiCr micro heater.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

Characteristics of Municipal Solid Wastes and Heating Value in Tourist Season of the eastern side of Gangwondo (강원 영동지역의 관광철 폐기물 및 발열량 특성)

  • Lee Hae-Seung;Choi Yong-Bum
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.66-75
    • /
    • 2006
  • When we looked at the seasonal food dregs of the eastern side of gangwondo, gangneung city's summer and winter food dregs showed 25.9 and 25.8% respectively due to the presence of beach areas and ski resorts. Sokcho city showed 28.12% in summer and yangyang gun's summer food dregs showed 40.2%. Yangyang gun's august food dregs showed 2.7 times larger than annual average amount. Outlook density showed regional characteristics. Data showed that food dregs' amount rate has been reduced gradually from 2005 because of the prohibition of direct filling up. As a result of compositions analysis, the eastern side of gangwondo's water fraction of living dregs were lower than that of chuncheon city where is located at the gangwondo's inland area. chuncheon city's data showed residential areas 53.5%, community areas 56.8% and commercial areas 55.6%. These discrepancies caused by the characteristics of dregs discharge type and climate. The caloric value of dregs has been increased incrementally after the ban of food dregs' direct filling up. Therefore, heating value of the dregs exceeds the existing furnace design spec and it can cause high caloric value problems, so we need additional research to solve these problems.

The Electromagnetic and Thermal Properties of Magnetic Core Materials for the Power Line Communication as the function of Additives (첨가제에 따른 전력선 통신용 자심 재료의 전자기적 특성 및 발열거동)

  • 오영우;이혜연;김현식;허정섭;민복기;김종령
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.2
    • /
    • pp.61-66
    • /
    • 2003
  • The electromagnetic properties and thermal behavior of Mn-Zn ferrite cores used for the blocking filter in he Power Line Communication(PLC) application were investigated as the function of additives. The highest density and permeability of 4.98 g/㎤) and 8,221 respectively were obtained to the specimen with composition of MnO 24 mol%, ZnO 25 mol% and Fe$_2$O$_3$ 51 mol% added MnO$_3$ 400 ppm, SiO$_2$ 100 ppm and CaO 200 ppm since the uniform grains were organized and the microstructures were compacted through reduction of pores. The permeability was increased up to 13,904 as temperature of specimen increased to 11$0^{\circ}C$, however, it was decreased precipitously under 100 over 11$0^{\circ}C$. The exothermic behavior was observed in the frequency range from 1 kHz to 1 MHz that the maximum temperature of specimens became 102$^{\circ}C$ at 1 MHz. In the consequence, the Mn-Zn ferrite core developed by this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to 93$^{\circ}C$ in the range of 10 kHz to 450 kHz bandwidth qualified for PLC.

Output characteristics of a continuous wave deuterium fluoride chemical laser (연속발진 불화중수소 화학 레이저 출력특성)

  • 이정환;박병서;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.65-69
    • /
    • 2002
  • A continuous wave deuterium fluoride (DF) chemical laser was designed and manufactured, and we have achieved DF laser beam generation with the maximum output power of 101 W. The gain medium is vibration-rotationally excited DF molecules produced by F+D$_2$ cold reaction through supersonic diffusion mixing in an optical cavity. F atoms are produced in a combustor by F$_2$+ H$_2$ reaction and injected into the cavity through a supersonic nozzle. The optimal chemical efficiency was measured to be 5.12% and specific power to be 96.5 J/g.