• Title/Summary/Keyword: 발열전원

Search Result 78, Processing Time 0.028 seconds

Characterization Analyses for Direct Current Tumor Ablation (직류 전류 이용 종양세포치료의 특성 연구)

  • Yang, T.K.;Kim, J.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.307-312
    • /
    • 2011
  • As a technique for removing cancerous tumors from normal tissue, radio-frequency electromagnetic waves were employed to heating target cells up to the critical temperature, which kills the cancerous cells. However, its use in treating tumors in soft organs is limited by inconvenient factors, which are use of high-currents and long time operation. In this work, the feasibility of the localized heating by inserting four conducting electrodes with tiny direct current is investigated. The heat source is resulting from the electric field as known as resistive heating. We have investigated the temperature distribution as a function of applying DC voltages ranging from 10 V to 30 V with 10 V step. From the simulation results, the mushroom-like lesion shape by applying 20 V is generated by four electrodes within a few minutes, that is proper to the clinical application.

Power Design of an S-Band Transmitter for KSLV-II with Derating (디레이팅을 고려한 한국형발사체 S-밴드 송신기 전원부 설계)

  • Kim, Seokkwon;Kim, Sung-Wan;Hong, Seung Hyun;Kim, Hyo Jong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.5
    • /
    • pp.339-347
    • /
    • 2019
  • The power circuit design of an on-board S-band transmitter for KSLV-II with derating(operation of a component at less than its maximum rated specification to enhance reliability) is investigated. The power circuit of the transmitter consists of linear voltage regulators, DC/DC converters for regulating the DC supply, and diodes for reverse voltage protection. After analyzing the load current of the components, derating requirements are explored. Furthermore, power dissipation and junction temperature rise are considered with respect to the load current. The analysis is compared to the results from an engineering model of the transmitter. The temperature of the components is derated by >$40^{\circ}C$ in an environment where the ambient temperature is $+60^{\circ}C$, which is the acceptance test specification of high temperature.

직류 전류 이용 종양세포의 효율적 치료에 관한 시뮬레이션 연구

  • Kim, Jae-Hong;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.289-289
    • /
    • 2010
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 암세포가 사멸되는 임계온도 보다 높게 악성조직에 열을 가하는 방법이 연구되어지고 있다 [1]. 전류가 흐를 수 있는 4개의 전기탐침을 종양조직에 삽입하여 국부적으로 열을 발생시키는 발열요법으로 암을 치료하는 연구가 고려되고 있다. 발열요법은 1960년대에 시작하여 우리나라에서는 1985년 연세 암센터에서 capacitive type의 RF heating 또는 전자파에 의한 국소가온법과 방사선치료와 병용으로 이용되고 있다. 주로 이용되는 방법은 Radio frequency heating, Microwave heating, ultrasound heating을 들수 있다. 라디오주파수는 보통 300 MHz 이하의 주파수를 가리킨다. 본 연구에서는 교류파 대신에 직류전원에 의해 열을 발생하는 경우에 관한 연구이다. 전극에 의해 형성되는 전기장에 대한 방정식은 전도매질에서의 DC 응용모드이고, 조직 내에서의 직류 전류에 의해 발생되는 온도 분포를 모델링하는 bioheat 방정식과 연계된 문제이다. 전기장에 의해 발생되는 열의 근원은 resistive heat 또는 Joule 열이다. 본 연구에서는 교류 전류에 의한 RF heating 대신 단순한 모델의 경우로 직류 전류에 의한 열 발생에 관한 이론적 연구를 수행하였다. 종양 조직 내에 삽입된 전극에 22V를 인가하면 60초 이내에 $80^{\circ}C$까지 급속히 증가 된 후, 서서히 $90^{\circ}C$에 까지 도달한다. 4 개의 전극에 대칭적인 전위가 인가 된 경우 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하게 하여 효과적인 치료를 수행 할 수 있는 조건을 제시한다.

  • PDF

An experimental study on the fire hazard of Sheath Heater (시즈히터의 화재위험성에 관한 실험 연구)

  • Kim, Hakjoong
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.511-517
    • /
    • 2014
  • Recently, the fire by sheath heater has been occurred frequently on winter season. The sheath heater has simple internal structure and boils water simply. Therefore, the use of sheath heater has been increased. In this study, found the fire hazard property of sheath heater from understanding the fire mechanism through the experiment to get the measure for decreasing the occurrence of fire. For the analysis of the fire hazard property of the sheath heater, performed the test of temperature change and ignition temperature by using current product. On the result of test, the sheath heaters are the most dangerous appliance to arise fire. Water temperature controller attached to sheath heater is not sufficient to prevent overheating it. The sheath heater should have level switch of water and temperature controller for heater itself to shut off the power supply. Because the cause of fire by sheath heater is overheating itself in the situation of lack water.

The Developed Study for SMPS to Protect the Noise and Inrush Current at LED Lighting Source (LED 광원에서 잡음 및 돌입전류 방지를 위한 스위칭모드 전원공급 장치 (SMPS) 개발 연구)

  • Chung, Chansoo;Hong, Gyujang;We, Sungbok;Yu, Geonsu;Kim, Mijin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.577-582
    • /
    • 2016
  • This Study focused on the development of SMPS (Switching Mode Power Supply) to supply the constant votage and current nevertheless LED fluorescent Light generated the electric noise (with Harmonics) and Inrush current at instant time of turn-on and off. Recently, according to the Green policy in government, the LED fluorescent Lighter showed the rapidly increasing tend as indoor and outdoor Lighter. But, because of costs, LED fluorescent Light not considered and neglected the following items; power factor, efficiency, Harmonics and Inrush current. So, we are developed the SMPS about 3 key issues as follows: 1st, power factor and efficiency is 85%. 2nd, the switching noisy by harmonic is minimized. 3rd, the Inrush current at turn on and off time is reduced the minimum 0.3 A after $100{\mu}sec$ on turnon time. The proposed SMPS adjusted by LNK 409 driver (included the high frequency modulation function). Although, the developed SMPS maintained the about 85% of power factor and efficiency. but, the SMPS must be generated low heat by the variation of minute load current at switching timing. To improve the above weak point, the developed SMPS have the feedback monitoring circuit between input side and output side to maintain the power factor and efficiency. Also, we are studied the time-constant of control circuit to output the constant voltage and current nevertheless the load disturbance of LED lighting. The LED fluorescent Light of 46W is checked the above items.

The Design of High efficiency multi-channel LED light Driver suitable for Streetlamp (가로등에 적합한 고효율 멀티채널 LED 조명 구동장치 설계)

  • Song, Je-Ho;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4489-4493
    • /
    • 2014
  • LED light driving device has problems in efficiency and heating at higher than 150W. In addition, there is inconvenience in replacing the lighting device to another when W is not the same as the previous one. In this paper, a multi-channel LED light driver, driver embedded driver circuit in a multi-channel structure with a power system in the driver-interlocking structure was designed. With the auto control converter structure with a power efficiency above 93% and power factor above 0.98, the weight of the high efficiency LED lighting-actuating device in driver-interlocking structure, a driver in self-calibrating self-optimization structure. In this paper, at below 10% THD, the existing converter contrast weight was reduced by 40% or more.

Design and Properties of the 300 W Planar Transformer (300 W급 평면 변압기의 설계 및 분석)

  • Lee, Hae-Yon;Heo, Jeong-Seob;Kim, Hyun-Sik;Kim, Jong-Ryung;Oh, Young-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.46-49
    • /
    • 2003
  • 전원장치의 소형 경량화 및 고효율화를 위한 핵심 기술인 변압기를 설계 및 제조하기 위해 넓은 유효단면적을 가진 평면 자성체와 편편하고 넓은 도체를 이용하여 고주파 손실을 감소시켜 고주파 대역용 전원장치에 채용 가능한 입력 220 V, 출력 15V, 300 W급 포워드(Forward) 평면 변압기를 설계 및 제조하고 전자기적 특성과 입출력 신호 특성을 측정하였다. 1차 코일과 2차 코일의 권선수는 각각 15회와 2회 그리고 여자(demagnetizing) 권선은 15회로 설계하였으며, 변압기의 총 발열은 $44.78^{\circ}C$로 설계 및 제작하였다. 스위칭 주파수 100kHz에서 1.65mH의 인덕턴스 값을 얻었으며, 100 V의 입력전압에 대하여 13 V의 안정한 구형 출력파형을 얻었다. 따라서 스위칭 듀티(duty)가 최고 0.4로 설계되었기 때문에 설계 목표한 15 V 출력에 유사한 전압을 나타내어 평면 변압기의 설계 방법을 확립하였으며, 평면 변압기의 응용 가능성을 확인할 수 있었다.

  • PDF

Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle (하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발)

  • Kim, Jong-Cheol;Choi, Deok-Kwan;Park, Hae-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.261-265
    • /
    • 2005
  • This paper describes the DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle. DC-DC Converter is used for charging 12V auxiliary battery supplying electric power to head ramp, audio, ECU etc in automobiles. used DC-DC Converter Topology is PS-ZVS FB(Phase Shifted Zero Voltage Switching Full-Bridge) to reduce switching loss and EMI noise induced by high frequency operating condition. And For easy compensation and stable system response characteristic, current mode control method including slope compensation is employed. Constant current / constant voltage charging control method guarantee stable electric charging of auxiliary battery. Simulation toll PSIM6.0 is used for initial circuit parameter settings and H/W debuging. Thermal problems of Switching components in DC-DC Converter is improved by using Thermo Tracer.

  • PDF

New High Performance and Low Cost Construction of Unified Power System for LCD TV Backlight Driver Circuitb (LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템)

  • Jang, Doo-Hee;Lee, Jae-Kwang;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jin-Wook;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A new high performance and low cost unified power system is proposed through investigating conventional Power-Integrated Drive(PID) system and Power-Separated Drive(PSD) system applied to LCD TV. Since the proposed system consists of two stage, namely power and inverter stage it features high efficiency and cost effectiveness. To satisfy the safety standard of the High voltage transformer, 1:1 transformer is employed between inverter and high voltage transformer. Moreover, to ensure the Zero Voltage Switching(ZVS) of all power switches and the Pulse Count Modulation(PCM) method is employed, which controls the number of pulse at the fixed frequency and fixed duty cycle. Therefore, it features high efficiency, improved heat generation, cost effectiveness and good EMI performance including no additional current balancing coil. To confirm the validity of proposed system, comparison of conventional system, verification of experimental results are presented.

Small bowel obstruction caused by an anomalous congenital band in an infant (신생아에서 발생한 선천성 밴드에 의한 장폐색증 1예)

  • Sung, Tae-Jung;Cho, Ji-Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.219-221
    • /
    • 2008
  • Intestinal obstruction is not uncommon in infants. The common causes of intestinal obstruction in the neonatal period are Hirschsprung disease, intestinal atresia, meconium ileus, and intussusception. However, small bowel obstruction caused by a congenital band is very rare. We report a 27-day-old baby who was admitted with abdominal distension and fever. The abdominal X-ray revealed massive bowel dilatation and the contrast gastrografin enema suggested a distal small bowel obstruction. The explolaparotomy showed small bowel entrapment due to an unusual anomalous congenital band.