• Title/Summary/Keyword: 발열기

Search Result 457, Processing Time 0.032 seconds

Development of Heater Driven by Motor by Using Eddy Current (와전류 발열장치를 응용한 모터 구동형 히터 개발)

  • Chai, Yong-Yoong;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.935-942
    • /
    • 2019
  • This paper descries the operation of a heater which was designed to control a motor that generates an eddy current. As the motor drives the rotor of an eddy current heater, magnetic fields are provided within the air gap between an eddy current heater's rotor and stator. Throughout the research, a rotor composed of 8 and 16 pieces of magnets was used to analyze which are the factors that affect the efficiency of this equipment. Test results showed that the magnetic fields are influenced by variable functions including the velocity of a motor and the quantity of magnets composing a rotor.

Rate Augmentation of Exothermic Hydration in the CaO Packed Bed (CaO 충전층의 수화발열반응 촉진)

  • Chung, Soo-Yull;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.91-101
    • /
    • 1994
  • Heat release characteristics of a CaO packed bed reactor which is used for a chemical heat storage device has been studied. We employed Cu-plate fins to release the heat of reaction of the CaO packed bed inside the reactor fast and effectively. Two-dimensional analysis of unsteady state heat flow inside the bed was performed as a function of time and under various conditions of the Cu-plates. It is noted that the time required to release the heat of reaction with Cu fins is reduced more than twice fast compared to that without Cu fins. That was largely dependent upon the number of Cu-plate, as well.

  • PDF

Effect of Temperatures to Crude Oil Productions with Rapeseed Straw on Application of Hydro-thermal Liquefaction Technology (Hydro-thermal Liquefaction Technology적용 시 유채대를 이용한 Crude oil생산에 미치는 반응온도의 영향)

  • Shin, JoungDu;Hong, Seung-Gil;Kwon, Soon-Ik;Park, Woo-Kyun;Park, SangWon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2010
  • Hydro-thermal liquefaction technology for rapeseed straws was investigated the biomass conversion rate with different catalysts and reaction temperatures. NaOH and KOH were used for catalysts, and the reaction temperature were ranged from 180 to $320^{\circ}C$ at every $20^{\circ}C$ of intervals for 10 minutes. The reaction was carried out in a 5,000 mL liquefaction system with dispenser and external electrical furnace. Raw materials (160g), 2,000 mL of distilled water and 10% (wt/wt) of catalyst to plant residue were fed into the reactor. It was observed that the maximum crude oil yield was about 36% at temperature range, $260{\sim}280^{\circ}C$ with KOH and at $300^{\circ}C$ with NaOH, respectively. It was observed that the more calorific values of crude oil, the higher reaction temperature with KOH, but it had the reverse pattern in NaOH.

Clinical Characteristics of Pulmonary Tuberculosis Presenting Prolonged Fever Despite Primary Short-Course Anti-tuberculosis Treatment (1차 항결핵약제 치료 후에도 지속적으로 발열을 보인 폐결핵 환자의 임상상)

  • Kim, Eun-Kyung;Hwang, Jung-Hwa;Song, Kun-Sick;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Shim, Tae-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.169-178
    • /
    • 2000
  • Background : Usually fever subsides within one week in over 90% of pulmonary tuberculosis (TBp) patients after the start of short-course anti-tuberculosis therapy, but occasionally it persists over two weeks after treatment. When the fever persists, drug resistance, combined infection, or drug fever, and so on, are considered as an etiology and, in some cases, drugs are changed. But inadvertent discontinuation of a short-course regimen inevitably will extend the duration of treatment, and the treatment completion may be delayed. This study was performed to investigate the causes of prolonged fever (PF) and to identify the predictors of PF in drug-susceptible TBp patients in Korea. Method : Five hundred-ninety-eight patients, who were admitted to Asan Medical Center from January 1996 to March 1999, diagnosed with TBp and prescribed short-course, anti-tuberculosis treatment, were reviewed. PF was defined as having fever over two weeks despite treatment. The causes of PF were analyzed. Drug-sus-ceptible TBp patients who presented no causes for PF, except turberculosis itself, were selected(n=22), and they were compared with those who had no fever at diagnosis (n=22) and those who had fever at diagnosis, which had subsided within two weeks after treatment (n=22). Clinical, laboratory, and radiological parameters were compared among the three groups. Results : Twenty-eight (4.8%) of 598 patients showed PF over two weeks despite short-course treatment. The causes of PF were drug fever (n=2), multi-drug resistant tuberculosis (n=3), disseminated Mycobacterium kansasii infection (n=1), and drug-susceptible tuberculosis itself (n=22). The patients with PF had more risk factors for tuberculosis, long duration of symptoms before treatment, night sweats, weight long, numerous acid fast bacilli on sputum smear, anemia, hyponatremia, hypoalbuminemia, over three lung cavity numbers and extensive infiltration, indicating that they had prolonged and extensive lung diseases. Conclusion : The main cause of PF in TBp despite short-course regimen seems to be drug-susceptible but extensive disease in Korea. Any changes to the drug regiment provided for TBp patients with prolonged fever despite treatment should be carefully considered.

  • PDF

Factors associated with Renal Scarring in Children with a First Episode of Febrile Urinary Tract Infection (소아의 첫 발열성 요로감염에서 신 반흔에 영향을 미치는 인자)

  • Jung Suk-Won;Jung Kyeong-Hun;Kim Myung-Hyun;Hong Young-Jin;Son, Byong-Kwan;Lee Ji-Eun
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.56-63
    • /
    • 2005
  • Purpose : Development of renal scarring is associated with delayed diagnosis and treatment of urinary tract infection(UTI). This study was performed to clarify how soon treatment should be started to Inhibit renal scarring after onset of UTI and the factors associated with renal scarring in children with a first episode of febrile UTI. Methods : We retrospectively reviewed 163 patients with a first episode of febrile UTI under the age of 2 years from April 2000 to Ap,il 2004. All patients had a DMSA renal scan and voiding cystourethrogram done in the diagnostic period, 6 months after which a follow-up renal scan was done. After patients wet-e divided into 2 groups according to the duration of fever prior to start of treatment, the duration of fever after start of treatment, and total duration of fever, initial and follow-up DMSA scan findings were analyzed among the different groups. We compared the factors associated with renal scars between the groups with and without renal scars. Results : The initial DMSA renal scan identified abnormal finding in 23% of the patients who were treated $\leq$24 hr from the onset of disease and in 43% of those with fever more than 24 hr. Renal scars developed in 33% of patients who were treated $\leq$24 hr and 38% of those with fever >24 hr prior to treatment. Renal scars developed in 34% of patients with remission of fever $\leq$48 hr after treatment and ill 50% of those with fever >48 hr after treatment. The risk for renal scars was significantly higher in children who had total duration of feyer >72 hr(67%) than in those with shorter duration(19%). In children with renal scars, VUR was most highly associated with an increased risk of renal scar formation. Conclusion : Although children with a first episode of febrile UTI are treated within 24 hr after onset of the fever, renal damage cannot be prevented completely and it is mainly associated with VUR. (J Korean Soc Pediatr Nephrol 2005;9:56-63)

  • PDF

A Numerical Analysis on the Thermal Protection System Applied Phase Change Material (상변화물질을 이용한 열방어체계의 수치해석 연구)

  • Oh, Chang-Mook;Yoo, Yung-Joon;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.80-86
    • /
    • 2012
  • This study is for figuring out a possibility of realization of the thermal protection system(TPS) for temporary use under high temperature condition and improving a design of the future TPS. On this purpose, environmental condition of the system has been simplified: the boundary conditions consist of a internally heating surface and a externally heated surface which is simulating the external high temperature condition. Configuration of the system is simplified as a hexahedon. Melting characteristics of the phase change material(PCM) and air temperature variation of TPS with or without connector have been numerically analyzed and compared. As a result of numerical analysis, the heat from the internally heated surface could not be effectively transferred. Therefore, temperature of inner space has been increased.

Energy saving control system of wireless base station utilizing natural air-conditioning (자연공조를 활용한 무선기지국 Energy절감 제어시스템)

  • Ryu, Gu-Hwan;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.223-232
    • /
    • 2019
  • With the development of the information communication industry, the size of the communication device has been reduced to a system that generates a large amount of heat. Therefore, since the amount of heat generated by the wireless equipment is large in the wireless base station, the energy consumption is continuously consumed and the failure of the wireless base station may occur. Therefore, in this study, The study was analyzed. As a research method, we performed base station with a lot of calorific value and electric charge. We selected 25 base stations and obtained data for two weeks. To ensure reliability, the room temperature was kept constant at $27^{\circ}C$, and the control system was installed and equiped for two weeks to obtain the date analysis. In order to calculate the test results in the study method, the instrument was used with a computer, a digital thermometer, and dust measurement. For the date analysis, we conducted a research study on 25 wireless basestations before and after the installation of Control Sysetm.

A Study on the Fabrication of Surface Heating Panel Using SiC Ceramics (SiC계 세라믹을 이용한 면상발열 판넬 개발에 관한 연구)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.604-608
    • /
    • 2016
  • In recent years, research and development has been carried out in order to increase the economical efficiency and stability in terms of efficient use of energy for the heating apparatus. Especially, technology development for high performance and new functional materials is actively being carried out. This paper focuses on the development of exothermic products with excellent energy transfer characteristics. The heating element used for bedding or mattress uses a heating wire. Since the heating wire is thin, the distribution of heat is concentrated only around the heating wire,. In addition, electromagnetic induction is harmful to the human body and energy consumption is high. Therefore, it is aimed to develop a planar heating panel using SiC ceramics which can radiate far-infrared rays and anions to be harmless to the human body, but also has excellent heat conduction to enhance energy efficiency.

Analysis of Temperature Change of Tunnel Lining with Heating Element (발열체가 적용된 터널 라이닝 내부 및 배면의 온도변화 분석)

  • Jin, Hyunwoo;Kim, Teasik;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.5-12
    • /
    • 2017
  • The damage of the tunnel lining on the cold regions can be represented by cracks and leaks caused by freezing of ground water. However, domestically, the relevant construction guidelines are not provided so far. Thus, in this research, the mechanical behavior and thermal conductivity of designated tunnel area are measured using instrumentation system installed in the lining concrete inside tunnels in order to analysis their behavior with regard to temperature variations. Previous research mainly focused on the effect of temperature on the tunnel lining based on the air and initial ground temperature at urban regions. Thus, this study analyzes effects of air temperature and initial ground temperature of designated tunnel area at the cold regions. The temperature of the groundwater at the backfill of the tunnel lining are analyzed to evaluate the heating element. Numerical analyses are performed to evaluate the heating element with regard to the various initial ground temperatures.