• Title/Summary/Keyword: 반사 손실

Search Result 1,005, Processing Time 0.03 seconds

Internal Antenna Design for GSM900/DCS1800/PCS1900 Using an Overlap of Return Loss (반사 손실 합성법을 이용한 GSM900/DCS1800/PCS1900 내장형 안테나 설계)

  • Jang, Byung-Chan;Kim, Che-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.503-510
    • /
    • 2007
  • This paper proposes the design scheme of internal triple band antenna intended for using in GSM900, DCS1800, and PCS1900 bands. The suggested folding metal plates of the two branches are mounted on a dielectric coated ground plane for size miniaturization and durability. Return losses are overlapped when length of metal branches are controlled. This is important technique for wide band operation. For the suggested antenna geometry its return loss was calculated by HFSS 9 simulator, and was shown to be -10 [dB] less within the required band. Also, gain and radiation pattern of antenna were measured using far field measurement system in an anechoic chamber. The measured peak gain is more than 3.0 [dBi], and the average gain is over -1.0 [dBi] for the triple band, which is regarded as satisfactory for the internal antenna application. Also, the radiation pattern for two frequencies shows a similar shape each other within the required band.

Fabrication of Low Reflectance Optical Fiber Mirrors (저 반사율을 가진 광섬유 거울의 제작)

  • Park, Jae-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.39-44
    • /
    • 1998
  • Low reflectance optical fiber mirrors in the continuous length of the single mode fiber were fabricated using mechanical splices and pieces of fiber coated with $TiO_{2}$ dielectric film at the cleaved end. When fiber mirrors of refelctance of about 1% were produced, the insertion loss ranged from 0.055dB to 0.3dB and the average insertion loss was 0.15 dB. These mirrors could be produced easy in the field.

  • PDF

Reflection and Transmission Coefficients by a Circular Pile Breakwater (원형 파일 방파제에 의한 반사율과 투과율)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Using the mathematical model suggested by Bennet et al.(1992), the reflection and transmission coefficients by a circular pile breakwater has been investigated in the framework of potential theory. Flow separation due to sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of exact energy loss coefficient is critical to enhance the reliability of mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code. The energy loss coefficient can be obtained from the pressure difference between upstream and downstream. Energy loss coefficient is the function of porosity and the relation equation between them is suggested throughout the curve fitting processing. To validated the suggested relation, comparison between the analytical results and the experimental results is made for four different porosities with good agreement.

Frequency Dependence of High-frequency Bottom Reflection Loss Measurements (고주파 해저면 반사손실의 주파수 종속성 측정)

  • 박순식;윤관섭;최지웅;나정열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.652-659
    • /
    • 2003
  • High-frequency(40∼120 kHz) reflection loss measurements on the water-sandy sediment with a flat interface were conducted in a water tank for various grazing angles. The water tank(5×5×5 m) was filled with a 0.5 m-thick-flat bottom of 0.5ø-mean-grain-size sand. Reflection losses, which were experimentally obtained as a function of grazing angle and frequency, were compared with the forward loss model, APL-UW model (Mourad & Jackson, 1989). For frequencies below 60 kHz, the observed losses well agree with the reflection loss model, however, in cases for frequencies above 70 kHz, the observed losses are greater by 2∼3 dB than the model results. The model calculation, which does not fully account for the vertical scale of roughness due to grain size, produce less bottom losses compared to the observations that correspond to large roughness based on the Rayleigh parameter in the wave scattering theory. In conclusion, for the same grain-size-sediment, as frequencies increase, the grainsize becomes the scale of roughness that could be very large for the frequencies above 70 kHz. Therefore, although the sea bottom was flat, we have to consider the frequency dependence of an effect of roughness within confidential interval of grain size distribution in reflection loss model.

Design and Fabrication of K Band Push-Push Dielectric Resonator Oscillator (K 대역 Push-Push 유전체 공진기 발진기 설계 및 제작)

  • 정재권;박승욱;김인석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.613-624
    • /
    • 2002
  • Electrical characteristics of two types of 20 GHz Push-Push GaAs MESFET dielectric resonator oscillators having Wilkinson and T-junction power combiners for the output stage have been investigated and compared. So we have explained that the output power and phase noise properties of the Push-push FET DRO are depending on return loss and isolation characteristics of power combiner at the fundamental and the second harmonic frequencies. A Push-push oscillator for suppressing the fundamental frequency of 10 GHz and enhancing the second harmonic of 20 GHz has been designed and fabricated in microstrip configuration on 20 mil thick RT-Duroid($\varepsilon$$_{r}$ = 2.52) Teflon substrate. Return loss and isolation characteristics of T-junction and Wilkinson have been measured at the fundamental frequency of 10.2 GHz and the second harmonic frequency of 20.5 GHz. At the fundamental frequency, -12 dB return loss and -3.7 dB isolation have been measured for the T-junction power combiner, and -14 dB return loss and -11 dB isolation fur the Wilkinson power combiner. At the second harmonic frequency, -10 dB return loss and -7.5 dB isolation have been obtained for the T-junction power combiner, and -23 dB return loss and -22 dB isolation for the Wilkinson power combiner. As a result, we have confirmed that the oscillator based on the Wilkinson power combiner with better retrun loss and isolation characteristics produces more output power and better phase noise characteristics..

Measurements of Mid-frequency Bottom Loss in Shallow Water of the Yellow Sea (서해 천해환경에서의 중주파수 해저면 반사손실 측정)

  • Yoon, Young Geul;Lee, Changil;Choi, Jee Woong;Cho, Sungho;Oh, Suntaek;Jung, Seom-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.423-431
    • /
    • 2015
  • KIOST-HYU joint acoustics experiment was performed on the western shallow water off the Taean peninsula in the Yellow Sea in May 2013. In this paper, mid-frequency (6~16 kHz) bottom loss data measured in a grazing angle range of $17{\sim}60^{\circ}$ are presented and compared to the predictions obtained using a Rayleigh reflection model. The sediment structure of the experimental site was characterized by multi-layered sediment and the components of the surficial sediment consisted of various types of particles with a mean grain size of $5.9{\phi}$. The model predictions obtained using the mean grain size were not in agreement with the measured bottom loss, and those obtained using the grain size of $4{\phi}$, which was estimated by an inversion process, showed a best fit to the measurements. It would be because the standard deviation of the gain-size distribution of surficial sediment is $4.3{\phi}$, which is much larger than those of other areas around the experimental site. Finally, the model predictions obtained using the geoacoustic parameters estimated from the inversion process for the surficial sediment layer and those corresponding to the mean grain size of $1.3{\phi}$ for lower layer are reasonably agreement with the measured bottom loss data.

Prototype Phase Array Antenna using Ferroelectric Phase Shifter (강유전체 위상변위기를 이용한 위상배열 안테나)

  • Moon, Seung-Eon;Ryu, Han-Cheol;Kwak, Min-Hwan;Kim, Young-Tae;Lee, Sang-Seok;Lee, Su-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.127-130
    • /
    • 2003
  • 4-bit 강유전체 위상변위기를 이용하여 10 GHz, 상온에서 작동하는 위상배열 안테나를 설계 및 제작하였다. 이 안테나는 빔 스캔을 위하여 전압에 대한 비선형특성을 보이는 강유전체 Bal-xSrxTiO3 (BST)를 기본으로 하는 위상변위기를 이용하였다. 우리는 펄스레이져 증착법으로 MgO (001) 기판위에 걸맞게 증착된 BST 박막을 일반적인 사진공정과 식각법을 이용하여 동일평판형 전극을 가진 위상변위기를 만들었다. 일반적인 동일평판형 강유전체 위상변위기의 경우 연결 전송선로의 임피던스와의 차이로 인해 반사손실과 이로 인한 부가적인 삽입손실이 발생한다. 이런 손실들을 줄이기 위해 입력과 출력 포트에 임피던스 매칭을 하였다. 이렇게 테이퍼링되어 만들어진 동일평판형 위상변위기는 이전의 구조에 비해 반사 손실과 삽입 손실 값에서 각각 약 10, 2 dB 정도씩의 개선을 보였다. 이 구조로 전송선로의 길이를 길게하여 만든 1-bit 강유전체 위상변위기는 10 GHz, 150 V의 전압변화에서 180도의 차등위상변위를 보였으며 최대 삽입손실과 최대 반사손실은 각각 약 10 dB, 20 dB 이다. 안테나 모듈은 4개의 마이크로스트림 패치 안테나와 4개의 강유전체 위상변위기로 이루어졌는데 10 GHz, 150 V의 전압변화에서 약 15도의 빔 스캔을 확인하였다.

  • PDF

Characteristics of Virtual Reflection Images in Seismic Interferometry Using Synthetic Seismic Data (합성탄성파자료를 이용한 지진파 간섭법의 가상반사파 영상 특성)

  • Kim, Ki Young;Park, Iseul;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.2
    • /
    • pp.94-102
    • /
    • 2018
  • To characterize virtual reflection images of deep subsurface by the method of seismic interferometry, we analyzed effects of offset range, ambient noise, missing data, and statics on interferograms. For the analyses, seismic energy was simulated to be generated by a 5 Hz point source at the surface. Vertical components of particle velocity were computed at 201 sensor locations at 100 m depths of 1 km intervals by the finite difference method. Each pair of synthetic seismic traces was cross-correlated to generate stacked reflection section by the conventional processing method. Wide-angle reflection problems in reflection interferometry can be minimized by setting a maximum offset range. Ambient noise, missing data, and statics turn to yield processing noise that spreads out from virtual sources due to stretch mutes during normal moveout corrections. The level of processing noise is most sensitive to amplitude and duration time of ambient noise in stacked sections but also affected by number of missing data and the amount of statics.

Evaluation of the performance of silencer (소음기의 감음성능 평가)

  • 김석홍;이홍기;이상엽;이규배;이규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • 본 연구에서는 덕트내 입사파와 반사파의 분리가 가능한 2개 마이크로폰법 (Two-sensor Method)의 입사파와 반사파의 분리측정 정밀도를 확인하고 이 방법에 따라 입사파 음향인텐시티만을 분리 측정하여 투과손실을 구하고 이 값과 ASTM E 477규격에 따른 삽입손실 측정값을 상호 비교검토하고자 한 다.

  • PDF

압축 센싱과 산술 부호의 연접을 통한 초음파 반사 신호의 손실 압축 방법

  • Im, Dae-Un;Kim, Se-Yun;Jo, Nam-Ik;Kim, Jeong-Seok
    • The Magazine of the IEIE
    • /
    • v.38 no.1
    • /
    • pp.50-55
    • /
    • 2011
  • 초음파 시스템은 진단 영상뿐만 아니라 초음파 수술과 같이 초음파를 사용하여 특정 세포를 제거하거나, 또는 일반적인 수술을 위한 가이드 영상을 제공하는 등 그 활용이 증가되고 있다. 반면, 기존 초음파 시스템은 크기가 커서 클리닉 센터나 종합병원 등에서 이동성 및 공간 효율성이 낮고 환자에 관한 주치의들의 진단 활동 반경이 매우 제한적이라는 불편함을 초래한다. 본 논문은 서버 클라이언트 기반의 무선 초음파 진단 시스템에서 프루브가 수신한 초음파 반사 신호를 무선으로 실시간 전송하기 위해서 압축센싱과 산술 부호의 연접을 통한 손실 압축 알고리즘을 제안한다.

  • PDF