• Title/Summary/Keyword: 반복표준편차

Search Result 164, Processing Time 0.028 seconds

Estimation of conbined uncertainty for dioxin reference materials from the fly ash (소각재에 함유된 다이옥신의 확장불확도 평가)

  • Kim, Woo-Il;Shin, Sun-Kyoung;Lee, Su-Young;Kim, Dong-Hoon;Kang, Hak-Gu;Han, Jin-Suk
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.363-370
    • /
    • 2010
  • This study was performed to validate reference materials (RMs) for proficiency testing (PT) in waste inter-laboratories. Dioxin RMs were prepared from fly ash in industrial incinerators. The relative standard deviations (RSDs) of analytical results were 2.6~15.7% for the dioxin RMs in 10 replicates (between and withinbottles). Data were collected and statistical analysis was performed by the One-way ANOVA test. The combined uncertainties of target isomers in dioxin analysis were 0.114~7.091.

Deviation of Heavy-Weight Floor Impact Sound Levels According to Measurement Positions (마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차)

  • Oh Yang-Ki;Joo Moon-Ki;Park Jong-Young;Kim Ha-Geun;Yang Kwan-Seop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.49-55
    • /
    • 2006
  • Measurement of impact sound insulation of floor, by current Korean Standard KS F 2810-2. is to be made with peak levels over 4 point in a receiving room. But it is often the case that there is inconsistency in results at various receiving points in the receiving room. Such variations obviously have effects on the repeatability and reproducibility of measured data. The result shows that there are even 10 dB deviations in 63Hz octave band frequency range and relatively less variations are occurred in other low frequency ranges. Such variations seems to be coming from modal overlaps of the receiving room. According to current rating method of floor impact sound. KS F 2863-2, that may affect on the single number latins scheme. From the result of tests in this study, there are 2dB to 6dB differences in the sin91e number with the combination of measurement points. This means that the reduction of measurement variations from the microphone positions is needed for a better credibility of measurement results.

Analysis Method Development for Bound-MCPD (3-MCPD 지방산에스테르 분석법)

  • Woo, Sung-Min;Oh, Jae-Ho;Jang, Young-Mi;Kim, Mee-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.294-302
    • /
    • 2010
  • Toxicity of 3-MCPD that comes from food manufacture and processing is well-known. Recent studies reported that 3-MCPD fatty acid ester which is formed by metabolic material was 10~2000 times as much as 3-MCPD in food. This study made analysis method of 3-MCPD fatty acid esters by recent research and laboratory work, and determined the content of 3-MCPD and 3-MCPD fatty acid esters in sources and meat processing products. 3-MCPD fatty acid esters were analysed by GC/MS, which were hydrolyzed from fatty acid and then transferred 3-MCPD was extracted and reacted with derivative subject. As a result of analysis method validation, LOD was 5.4ppb, LOQ was 9.0ppb.

A Noise-Robust Measuring Algorithm for Small Tubes Based on an Iterative Statistical Method (통계적 반복법에 기반한 노이즈에 강한 소형튜브 측정 알고리즘 개발)

  • Kim, Hyoung-Seok;Naranbaatar, Erdenesuren;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • We propose a novel algorithm for measuring the radius of tubes. This proposed algorithm is capable of effectively removing added noise and measuring the radius of tubes within allowable precision. The noise is removed by using a candidate true center that minimizes the standard deviation with respect to the radius. Further, the disconnection in data points resulting from noise removal is solved by using a connection algorithm. The final step of the process is repeated until the value of the standard deviation decreases to a small predefined value. Experiments were performed using circle geometries with added noise and a real tube with complex noise and that is used in the braking units of automobiles. It was concluded that the measurement carried out using the algorithm was accurate within 1.4%, even with 15% added noise.

Evaluation of the consistency and homogeneity of artificial latent fingerprint printed with artificial sweat (인공땀으로 출력한 인공지문의 균질성 평가)

  • Hong, Ingi;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.26-32
    • /
    • 2015
  • The consistency and homogeneity of repetitive printing of artificial fingerprint were evaluated using a visual minutiae comparison method and an Automated Fingerprint Identification System (AFIS). The standard latent fingerprint pattern was prepared by the printing of a master digital fingerprint pattern with an inkjet printer cartridge case filled with artificial sweat. The master digital fingerprint pattern was prepared with a scanning of an inked fingerprint pattern of a living subject. The intensities of the master digital fingerprint pattern were adjusted by changing the 'output level' values of the Adobe Photoshop CS 5 software. Number of standard latent fingerprint patterns were printed and then developed with conventional latent fingerprint developing methods; ninhydrin treatment method and 1,2-indandion(1,2-IND)/$ZnCl_2$ treatment method. The ridge details of the latent fingerprint patterns developed with the reagents were visually compared with the inked fingerprint pattern and could confirm that the minutiae of both patterns are visually identical. The ridge detail of the inked fingerprint and reagent developed standard latent fingerprint patterns were compared with an AFIS. The average number of minutiae searched by the AFIS was $52.4{\pm}2.4$ (range = 48~56) for 50 ninhydrin developed latent fingerprint patterns, and $50.2{\pm}1.9$ (range = 47~53) for 50 1,2-IND/$ZnCl_2$ developed latent fingerprint patterns. These low standard deviation values over 50 repetitive printing demonstrated that the 50 standard latent patterns were printed with consistent and homogeneous manner.

Adaptation to Health Perception and Use of Yansaeng in Middle-aged Korean Womens (중년여성의 건강지각에 따른 양생 이행에 관한 연구)

  • Kim, Mi-Young;Jun, In-Gyeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.913-916
    • /
    • 2011
  • 본 연구는 중년의 건강지각과 양생 이행간의 관계를 파악하여 중년의 건강증진에 도움이 되고자 본 연구를 시도하였다. 방법 : 부산광역시 K 대학 사회교육원 및 K대학 야간 재학생 및 사회교육원에 수강중인 250명 가운데 일부 자료가 누락된 56명을 제외한 총 194명을 대상으로 분석하였다. 자료 분석은 spss win 18.0 을 사용하여 다음과 같이 분석하였다. 일반적 특성은 빈도와 백분율, 건강지각 정도와 양생 이행정도는 평균과 표준편차로, 일반적 특성에 따른 건강지각과 양생 이행 정도는 t-test와 ANOVA, Scheffe' test, 건강지각과 양생 이행 정도의 상관관계는 Pearson's correlation으로 분석하였다. 결과 :중년여성의 일반적 특성에 따른 건강지각은 연령에서 통계적으로 유의한 차이가 있었다. 중년여성의 일반적 특성에 따른 양생은 결혼여부, 직업 상태와 음주 경험에 통계적으로 유의한 차이가 있었다. 건강지각과 양생 간의 상관관계에서는 유의한 상관관계가 없었다. 결론 : 본 연구의 추후 효과를 규명하기 위한 반복연구와 건강지각과 양생의 간호중재프로그램의 효과 검증하는 연구가 필요하다.

  • PDF

Sensitivity to differences in the extent of neck retraction and rotation movements made with and without vision (시각 차단 유무에 따른 경부 후인과 회전의 운동 감각 비교)

  • Lee, Haejung;Nicholson, Leslie L.;Adams, Roger D.
    • PNF and Movement
    • /
    • v.2 no.1
    • /
    • pp.59-69
    • /
    • 2004
  • 목적 : 본 연구는 경부의 후인과 회전 운동 범위에 있어 운동 감각 역치의 차이를 비교하기 위해 수행되었다. 방법 : 본 연구의 대상자는 19명(10명 남자, 9명 여자 나이 19~30세 평균 23.2, 표준편차 3.3)이 참가하였다. 이 연구에서 운동 감각 역치는 편안히 앉은 자세에서 시각 차단시와 시각 허용시에, constant stimuli의 방법을 사용하여 반복 측정되었으며, 움직임을 수행 하는 과정에서 정지 상태를 유도하여 그 정지동작에서 두 동작의 차이를 평가하였다. 결과 : 본 연구의 결과 후인 운동 감각이 오른쪽 또는 왼쪽 회전 운동 감각 보다 더 민감하게 나타났다. 결론 : 중간 범위의 두 움직임간의 차이를 비교할 때 시각차단 유무는 각 운동 감각에 영향을 미치지 않았다.

  • PDF

Development of Visual Inspection System to the defect of Quad chip (Quad chip의 외관 불량 검사 시스템 개발)

  • Lee, Ji Yeon;Ko, Kuk Won;Han, Chang Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1076-1077
    • /
    • 2015
  • 본 연구에서는 최근 널리 사용되고 있는 QFP(Quad Flat Package)의 소형화 및 대량 생산 Quad chip 공정에서 최종 외관 불량 검사를 위한 기존의 2D 영상 검사 시스템에 3D 영상 검사 시스템을 추가하여 광학 장치를 설계하고 이에 따른 영상처리 알고리즘을 개발하였다. 개발된 검사 장치는 실제 LQFP/TQFP에 생산 공정에 적용되어 불량을 검사에 적용하였으며, 10 회 반복 측정 시 최대 오차는 $1.34{\mu}m$와 측정 오차의 표준편차가 $0.715{\mu}m$으로 요구하는 3차원 불량 검사를 만족할 만한 성능을 보였다.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Channel estimation scheme of terrestrial DTV transmission employing unique-word based SC-FDE (Unique-word 채용한 SC-FDE 기반 지상파 DTV 전송의 채널 추정 기법)

  • Shin, Dong-Chul;Kim, Jae-Kil;Ahn, Jae-Min
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.207-215
    • /
    • 2011
  • A signal passed through multi-path channel suffers ISI(Inter-Symbol Interference) and severe distortions caused by channel delay spread and noise components at the SC-FDE(Single Carrier with Frequency Domain Equalizer) transmission. Conventional UW(Unique-Word) based SC-FDE iterative channel estimation improves channel estimation performance by smoothing estimated CIR(Channel Impulse Response) of the noise components outside the channel length at time domain and restoring the broken cyclic property through UW reconstruction. In this paper, we propose channel estimation scheme through noise suppression within channel length. To suppress the noise, we estimate noise standard deviation as estimated CIR of the noise components outside the channel length and make criteria of the noise standard deviation gain that doesn't affect the original signal samples. When estimated CIR samples within channel length are less than the criteria value using the noise standard deviation and gain, the noise components are removed. Simulation results show that the proposed channel estimation scheme brings good channel MSE(Mean Square Error) and good BER(Bit Error Rate) performance.