• Title/Summary/Keyword: 반발도 시험기

Search Result 10, Processing Time 0.032 seconds

An Experimental Study on the Rebound Degree Tendency of Linear Hitting Test Hammer (선 타격 반발도 시험기의 반발도 경향에 관한 실험적 연구)

  • Ahn Hyo-Soo;Seo Chee-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.313-322
    • /
    • 2005
  • Recently, as the remodeling market gradually substitute for new construction market and safety diagnosis for reconstruction apartment become a matter of principal Interest, it is demanded that scientific diagnosis and evaluation for existing concrete structure state. And it is increasing that the significance for reliability of data which is used for estimating the concrete compressive strength by nondestructive test. As a result, it is found that different proposal to material age and hitting angle is good to improving the reliability of presumption of concrete compressive strength in the linear hitting rebound test hammer. And for the reason that mutual relation between the compressive strength and rebound degree is highest in linear hitting rebound test hammer 25mm in all portion according to early md middle material age and hitting angle except the early material age $-45^{\circ}$, analysis showed that linear hitting rebound test hammer is more reliable than existing schmidt hammer in presumption of concrete compressive strength.

Analysis on the Characteristics of the Superconducting Electrodynamic Suspension According to the Variation of the Ground Conductor (지상도체 변화에 따른 초전도 반발식 자기부상 특성 해석)

  • Bae, Duck-Kweon;Cho, Han-Wook;Lee, Jong-Min;Han, Hyung-Suk;Lee, Chang-Young;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1159_1160
    • /
    • 2009
  • This paper presents the numerical simulation results on the supercodnucting electrodynamic suspension (EDS) simulator according to the variation of the ground conductor. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible way to simulate the EDS system were simulated in this paper by using finite element method (FEM). The static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.

  • PDF

Measurement of Physical Properties of Pepper for Particle Behavior analysis of sorting system for Pepper Harvester (고추수확기용 선별장치의 입자 거동 해석을 위한 고추 물성측정)

  • Byun, Jun Hee;Kim, Su Bin;Kim, Myoung Ho;Kim, Dae Cheol
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.9-9
    • /
    • 2017
  • 입자거동해석소프트웨어(EDEM)은 DEM(Discrete Element Method)기법을 이용한 입자 거동 전용 해석툴로 입자 유입량, 위치 등을 조절하여 입자거동과 관련된 제품 개발, 프로세스 최적화를 위한 비용 및 시간 절감에 활용도가 뛰어난 소프트웨어이다. EDEM을 활용하기 위해선 적용대상에 대한 물성치를 적용하여야 한다. 따라서 본 연구에서는 EDEM를 이용하여 현재 연구개발 중인 카드클리너 방식의 고추 선별기의 성능을 분석을 수행하기 위해 고추 물성측정 실험을 수행 하였다. EDEM을 이용한 입자거동해석에 필요한 개인 물성치에는 포아송비, 전단탄성계수, 밀도가 있다. 또한 입자-입자, 입자-Geometry 간의 상호관계를 위한 물성치인 반발계수, 정지마찰계수, 구름마찰계수가 필요하다. 공시 시료인 고추는 광주광역시 남구 승촌동 소재의 개인농가 Plastic 온실로 재배된 '천상'품종을 사용하였다. 푸아송 비와, 전단 탄성계수를 측정하기 위한 인장시험기기로는 만능인장시험기(TA-XT2, Stable Micro, 영국)를 이용하였으며, 인장에 의한 고추의 변형량 축정은 초고속카메라(NX4-SI, IDT, 미국)을 이용하였다. 밀도는 비중병법에 기초하여 질량과 부피를 측정하여 밀도를 계산하였다. 반발계수는 고추의 충돌 실험을 통해 변화한 높이를 이용하여 계산하였고, 충동 실험을 통해 변화한 높이는 초고속카메라를 이용하여 측정하였다. 정지마찰계수와 구름마찰계수는 고추의 미끄러짐이 시작하는 각도와 등속도 운동으로 구르는 각도를 초고속카메라를 이용하여 측정 후 계산하였다. 모든 실험은 3번 반복을 통해 평균값을 시험 결과 값으로 이용하였다. 고추의 대한 물성치 실험결과 고추의 푸아송 비는 0.294(std : 0.2), 전단탄성계수 4.624E+06 Pa, 밀도 $600kg/m^3$로 나타났다. 또한 입자-입자 간의 물성치인 반발계수는 0.383, 정지마찰계수는 0.455, 구름마찰 계수는 0.043로 나타났다. 추후 본 연구에서 측정한 고추의 물성치를 적용한 EDEM 입자거동해석 시뮬레이션을 통해 카드클리너 방식의 고추 선별기의 성능에 대한 분석을 하고자 한다.

  • PDF

A Prediction of Engineering Properties of Ulsan Sedimentary Rocks with Schmidt Hammer Rebound Number (Schmidt hammer 반발지수로 울산지역 퇴적암의 공학적 특성을 추정하기 위한 연구)

  • Min, Tuk-Ki;Moon, Jong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.139-150
    • /
    • 2006
  • A study has been made of the Schmidt hammer rebound test for the estimation of engineering and physical characteristics of sedimentary rocks. As there is no universal formular for the estimation of rock strength due to geological conditions, in this study only sedimentary rocks are adopted to testing. The aim of study is to make the information more meaningful and useful for engineers and contractors by providing rapid, cheap and easy method. The obtained parameters were correlated and regression equations were established among Schmidt hammer rebound number, uniaxial compressive strength, tangent Young's modulus, indirect tensile stress, water absorption and porosity of rocks with high coefficients of correlation with each other.

Properties of No-coarse Lightweight Concrete Using Synthetic Lightweight Fine Aggregate (인공경량세골재(人工輕量細骨材)를 사용(使用)한 무조골재(無粗骨材) 경량(輕量)콘크리트의 특성(特性))

  • Min, Jeong Ki;Kim, Seong Wan;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.194-206
    • /
    • 1997
  • This paper was performed to evaluate the properties of no-coarse lightweight concrete using perlite and expanded polystyrene bead on fine aggregate. The results were shown that w/c and unit weight was affected by absorption ratio and unit weight of using aggregate itself. The compressive strength of no-coarse lightweight concrete was showed $187kgf/cm^2$ by using natural sand, $170kgf/cm^2$ by using perlite. Tensile and bending strength were showed the same tendency of compressive strength, but when expanded polystyrene bead concrete dose not have strength nearly. The pulse velocity and static modulus of elasticity of no-coarse lightweight concrete were smaller than that of normal cement concrete. And stress-strain curves were shown that was increased with increase of stress, and when the stress-strain curve using expanded polystyrene bead was repeated at short intervals increase and decrease irregularly.

  • PDF

Numerical Analysis of Moving Type and Static Type Electrodynamic Suspension Simulator with Superconducting Levitation Magnet (초전도 부상자석을 이용한 동적 및 정지형 반발식 자기부상 시험기의 수치해석)

  • Lee, E.R.;Bae, D.K.;Chung, Y.D.;Yoon, Y.S.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • This paper presents the numerical simulation results on the moving type electrodynamic suspension (EDS) simulator and static type EDS simulator using high-Tc superconducting (HTS) levitation magnet. The levitation force of the EDS system is formed by the reaction between the moving magnet and the fixed ground conductor. The possible two ways to simulate the EDS system were simulated in this paper by using finite element method (FEM). The first way was the moving type simulator which consists of the fixed HTS magnet and the moving ground conductor. The second way was the static type simulator which consists of the fixed magnet, the fixed ground conductor and the ac current supply system. To verify the characteristics of high speed EDS system with the moving type simulator heavy, large and fast moving ground conductor is needed. The static type simulator can get the characteristics of the high speed EDS system by applying equivalent ac current to velocity, therefore it does not need large moving part. The static type EDS simulator, which can consist of an HTS magnet, the fixed ground conductor(s), an AC power supply and the measuring devices, also test the effect of the shape of the ground conductor easily. The plate type ground conductor made stronger levitation force than ring type ground conductor. Although the outer diameter 335 mm ring type ground conductor (Ring3) was larger than the outer diameter 235 mm ground conductor (Ring2), the levitation force by Ring2 was stronger than that by Ring3. From the calculation results on this paper, the consideration of the magnetic flux distribution according to the levitation height should be included in the process of the ground conductor design.

The Physical and Mechanical Properties of No-Fines Lightweight Concrete Using Synthetic Lightweight Coarse Aggregate (인공경량조골재(人工輕量粗骨材)를 사용(使用)한 무세골재(無細骨材) 경량(輕量)콘크리트의 물리(物理)·가학적(加學的) 특성(特性))

  • Kim, Seong Wan;Min, Jeong Ki;Cho, Seung Seup;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.39-50
    • /
    • 1996
  • The normal cement concrete is widely used material to build the construction recently, but it has a fault to increase the dead load on account of its unit weight is large compared with strength. So, many engineers are continuously searching for new materials of construction to provide greater performance at lower density. Many studies were carried out on the lightweight aggregate concrete in foreign country in the latter half of the 19th century, therefore lightweight aggregate concrete has been used successfully for many years for structural members. The main purpose of the work described in this paper were to establish its physical and mechanical properties of no-fines lightweight concrete using synthetic lightweight coarse aggregates. Test results are summarized as follows ; The water-cement ratio was shown less than 33% in use synthetic lightweight coarse aggregates, unit weights of synthetic lightweight concrete was shown less than $1,800kg/m^3$ and compressive strength was higher than $200kg/m^2$. And the pulse velocity was more than 3,000m/sec. The relationship of compressive strength between unit weight and pulse velocity was shown to be approximately linear.

  • PDF

Study for the Development of a Main Oxidizer Shut-off Valve for Liquid Rocket Engines (발사체 연소기용 산화제 개폐밸브의 핵심요소 기술 개발)

  • Kim, Dohyung;Hong, Moongeun;Park, Jaesung;Lee, Soo Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.113-119
    • /
    • 2013
  • A main oxidizer shut-off valve (MOV) controls the supply of cryogenic liquid oxygen to the combustion chamber of liquid rocket engines by on/off operations. The main subjects to be introduced are not only the valve transient response during valve on/off procedures but also the characteristics of pneumatic and seat/poppet parts as core technologies in the development of the MOV, which is expected to be adopted for the Korea Space Launch Vehicle II. It is shown that the analytical prediction of the transient valve travel is in good agreement with experimental results. Friction and elastic forces on the valve moving part are quantitatively evaluated by structural analysis.

Development of High Speed Circuit Breaker using Electromagnetic Repulsion Actuator (전자기 반발 구동장치를 사용한 고속 차단기 개발)

  • Hwang, Kwang-Soo;Kim, Young-Il;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.441-448
    • /
    • 2022
  • In the distribution system, there are multiple power protection systems such as circuit breakers at substations, and reclosers, minimum circuit ampacities, fault interrupters on distribution lines. They are widely used to prevent partial outages, cascading power failure or blackout so that other healthy systems could maintain the integrity in case of the instant fault or permanent failure on the power lines. However, when a fault happens, it could cause a major black out due to the lack of the protection cooperation between the protection relay of the circuit breaker at a substation and a protection system on the distribution lines. To achieve the power system integrity better, it is required to develop the circuit breaker which can be operational within 1 cycle(16ms). In this study, the high speed circuit breaker which is filled up with eco-friendly gas is developed. This equipment achieved an excellent test results based on IEC 62271-111 standard. It is respected that this equipment would contribute to prevent the wide area blackout by isolating a fault area quicker and faster.

Study on the Stability Evaluation of Concrete Erosion Control Dam by using Non-destructive Test for Compressive Strength (콘크리트 비파괴시험법을 이용한 사방댐 안정도 평가에 관한 연구)

  • Park, Ki-Hyung;Kim, Min-Sik;Joh, Sung-Ho;Lee, Chang-Woo;Youn, Ho-Joong;Kim, Kyong-Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.1
    • /
    • pp.90-96
    • /
    • 2013
  • This study was conducted to investigate a stability trend within 6 above average and 4 blow average erosion control dams, which were selected by The Korean Association of Soil and Water Conservation and were built in 1990s in Gyeonggi and Gangwon Province. The study was aimed to measure rebound hardness of upstream face, flood way and downstream face from those dams selected by using 'Concrete Test Hammer'. The main purposes of the study are selection of compression strength prediction equation and scope of wavelength, which successfully demonstrate non-destructive test results for erosion control dams. There is an opportunity to increase disaster prevention ability when stability vulnerability of concrete erosion control dam is detected in a timely manner. Results of the compression strength investigation express that there is a consistency with visual inspection of stability that has been processed by The Korean Association of Soil and Water Conservation. We concluded that a prediction equation, which was developed by Architectural Institute of Japan (AIJ), shows highest suitability in Korean erosion control dams when stability investigation is performed. The detailed criteria for the test result are 'stable', 'detail inspection required' and 'poor' for over 300 $kgf/cm^2$, 250~300 $kgf/cm^2$ and below 250 $kgf/cm^2$ respectively. Standards for stability of Korean erosion control dam and a compression strength prediction equation (that corresponds to the standards of the stability) should be established on the basis of chronological data of erosion control dam compression strength. Systematical approach for stability inspection that carries out remodeling or repair when problem on erosion control structures are detected through visual inspection and simple stability test, is necessary for the future disaster prevention.