Abstract
This study was conducted to investigate a stability trend within 6 above average and 4 blow average erosion control dams, which were selected by The Korean Association of Soil and Water Conservation and were built in 1990s in Gyeonggi and Gangwon Province. The study was aimed to measure rebound hardness of upstream face, flood way and downstream face from those dams selected by using 'Concrete Test Hammer'. The main purposes of the study are selection of compression strength prediction equation and scope of wavelength, which successfully demonstrate non-destructive test results for erosion control dams. There is an opportunity to increase disaster prevention ability when stability vulnerability of concrete erosion control dam is detected in a timely manner. Results of the compression strength investigation express that there is a consistency with visual inspection of stability that has been processed by The Korean Association of Soil and Water Conservation. We concluded that a prediction equation, which was developed by Architectural Institute of Japan (AIJ), shows highest suitability in Korean erosion control dams when stability investigation is performed. The detailed criteria for the test result are 'stable', 'detail inspection required' and 'poor' for over 300 $kgf/cm^2$, 250~300 $kgf/cm^2$ and below 250 $kgf/cm^2$ respectively. Standards for stability of Korean erosion control dam and a compression strength prediction equation (that corresponds to the standards of the stability) should be established on the basis of chronological data of erosion control dam compression strength. Systematical approach for stability inspection that carries out remodeling or repair when problem on erosion control structures are detected through visual inspection and simple stability test, is necessary for the future disaster prevention.
이 연구는 '콘크리트 테스트 해머'를 이용하여 1990년대에 경기도와 강원도에서 시공된 사방댐 중 사방협회 에서 육안 점검한 사방댐 10기(양호 6기, 불량 4기)의 대수면, 방수로 및 반수면의 반발경도 측정을 통해 사방댐의 안정성을 파악하여 사방댐의 비파괴검사에 적합한 압축강도 추정식과 적정 판정범위를 정하는 것을 목적으로 진행하였다. 특히, 콘크리트 사방댐 본체의 안정성을 사전에 파악하게 되면 사방댐을 적시에 보수, 관리할 수 있고, 사방댐 본연의 기능인 토사유출방지기능을 최대화할 수 있다. 콘크리트 사방댐의 압축강도 조사한 결과, 현재 사방협회에서 진행 중인 안정점검 육안 점검 결과와 대부분 일치하였다. 또한, 안정점검시 압축강도는 일본건축학회에서 제시한 추정식을 적용하는 것이 적합할 것으로 판단되었으며, 판정 기준은 300 $kgf/cm^2$ 이상일 경우에는 '안정', 250~300 $kgf/cm^2$이 범위일 경우에는 '정밀검사 필요', $kgf/cm^2$ 미만일 경우에는 '불량' 판정을 내리는 것이 적합하다고 사료된다. 그리고 사방댐의 연대별 압축강도에 대한 자료를 충분히 축적하고, 이를 토대로 우리나라 사방댐에 적합한 안정기준과 압축강도 추정식이 필요하다고 사료된다. 앞으로는 육안 점검과 간이 안정성 검사를 통해 사방 구조물에 이상이 발견될 경우 정밀진단 검사를 실시하여 안정도를 파악하는 체계가 구축되어야 할 것이다.