Study of biofouling in Korea offshore wind farms (국내 해상풍력발전단지에서의 바이오파울링에 대한 연구)

  • Yoon Seok Chae;Ho Min Kim; Ji Hyung Kim;Sung Hoon Lee
    • Journal of Wind Energy
    • /
    • v.14 no.4
    • /
    • pp.43-49
    • /
    • 2023
  • We have studied biofouling in Korea's offshore wind farms by using image analysis through monitoring and surface energy analysis. To observe the biofouling characteristics, samples were fabricated using Micron extra 2 and PropOne, which have a self-polishing property, and Hempathane HS 55610, which is used in substructure coatings. The manufactured samples were installed at the bottom of a ladder in a substructure, and monitored for 10 months. The most biofouling occurred in the sample without the self-polishing property, and algae, barnacles and corallinales were observed. The surface energy analysis used the Owens-Wendt-Rabel and Kaelble (OWRK) model, which uses the contact angles of two standard fluids. As a result of calculating the surface energy using contact angle measurement, the sample without the self-polishing property showed the highest value. This result was consistent with the biofouling incidence observed through monitoring.

Study on Effects of Seawater Fouling on a Plate-Frame Heat Exchanger (해수 파울링이 판형 열교환기 성능에 미치는 영향에 대한 고찰)

  • Heo, Jaehyeok;Lee, Dong-Won;Kim, Min-Hwi;Baik, Wonkeun;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.391-400
    • /
    • 2017
  • Understanding of seawater fouling characteristics is critical in designing a heat exchanger adapted in an effluent utilization system for a power plant. We reviewed three types of fouling mechanisms of general, biological, and crystallizing for a plate-frame heat exchanger, to be used for heat exchanging with heated effluent from a power plant. Also, mathematical models for each type of seawater fouling were suggested. Actual thermal resistance calculated from seawater fouling models were compared and implemented in designing a plate-frame heat exchanger. The bio-fouling model revealed the largest thermal resistance and the highest number of plates for a plate-frame heat exchanger under the same heat load. Overall heat transfer coefficient and pressure drop of a plate-frame heat exchanger under fouling conditions was lower by 58 percent and higher by 2.85 times than those under clean conditions, respectively.

Review on Membranes Containing Silver Nanoparticles with Antibacterial and Antifouling Properties (항균 및 방오 특성을 가진 은나노 입자 함유 분리막에 대한 총설)

  • Kim, HanSol;Patel, Rajkumar;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.293-303
    • /
    • 2021
  • Separation membranes used in water filtration, protein purification or biomedical filtration device frequently undergo membrane fouling for several reasons. The formation of biofilm on the membrane surface by bacteria causes a severe problem for durability of the membrane. For the protein separation, the membrane pores get blocked due to surface hydrophobicity of the membrane. There are several approaches controlling the membrane fouling and one of them is the incorporation of silver nanoparticles. Antibacterial properties of silver nanoparticles are well known and thus widely used in several applications. In this review, we have focused on the membranes where silver nanoparticles or its derivatives are either incorporated in the active layer of thin film composite membranes or uniformly distributed throughout the whole membranes.

국내 선박부착생물 관리방안에 관한 연구

  • Ha, Sin-Yeong;Park, Han-Seon;Lee, Gyeong-Mi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.05a
    • /
    • pp.236-237
    • /
    • 2019
  • IMO는 MEPC 73차(2018.10) 회의에서 선박부착생물 관리절차, 방오성능, 수중소제, 선체설계 및 교육사항이 구체적으로 명시될 수 있도록 기존 지침의 유효성평가가 승인되었으며 수집된 정보를 바탕으로 관리지침서 개정을 검토하고 있어 향후 선박부착생물 관리 가이드라인도 규제화 될 가능성이 높다. 우리나라는 IMO 선체 부착생물규제 대응하기 위해 외래 유해침임종 관리를 위한 최적을 방안을 도출 할 필요가 있다.

  • PDF

A Study on Prevention of Fouling Formation by Reduction Reaction of CaSO4 in a Biomass Circulating Fluidized Bed Combustion (바이오매스 순환유동층 연소에서 CaSO4 환원반응에 의한 파울링 발생 방지 연구)

  • Seong-Ju Kim;Sung-Jin Park;Sung-Ho Jo;Se-Hwa Hong;Yong-Il Mun;Tae-Young Mun
    • New & Renewable Energy
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • A large amount of carbon monoxide (CO) is generated in circulating fluidized bed combustion, the process whereby a hot cyclone separates unburned fuel. However, calcium sulfate (CaSO4), when combined with a high CO content, can cause fouling on the surface of the steam tube installed inside the integrated recycle heat exchangers (INTREX). In this study, CaSO4 decomposition was investigated using 0.2-3.2 vol.% CO and 1-3 vol.% oxygen (O2) at 850℃ for 20 min in a lab-scale fluidized bed reactor. The results show that CaSO4 decomposes into CaS and CaO when CO gas is supplied, and SO2 emissions increase from 135 ppm to 1021 ppm with increasing CO concentration. However, the O2 supply delayed SO2 emissions because the reaction between CO and O2 is faster than that of CaSO4; nevertheless, when supplied with CaCO3, the intermediate product, SO2 was significantly released, regardless of the CO and O2 supply. In addition, agglomerated solids and yellow sulfur power were observed after solid recovery, and the reactor distributor was corroded. Consequently, a sufficient O2 supply is important and can prevent fouling formation on the INTREX surface by suppressing CaSO4 degradation.

Surface characterization and evaluation of biofouling inhibition of reverse osmosis membranes coated with Epigallocatechin gallate(EGCG)/vanillin (EGCG/바닐린 코팅 RO분리막의 표면 특성과 미생물막 억제능)

  • Jung, Jaehyun;Kim, Youngjin;Nam, Haewook;Kim, Yunjung;Lee, Eunsu;Lee, Younil;Kweon, Jihyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.713-723
    • /
    • 2014
  • Biofouling in brackish water reverse osmosis (RO) membranes still needs extensive research to understand cause and mechanism and to obtain methods for reduction of its impact on RO applications. Natural compounds with biofilm formation inhibitory properties are being investigated. Two compounds, vanillin and Epigallocatechin gallate (EGCG), were selected due to their great potential on biofilm formation inhibition. Vanillin shows inhibition on quorum sensing mechanisms of biofilm formation. EGCG has potential to inactivate microbial activity. The two compounds were incorporated in typical polyamide reverse osmosis membranes and evaluated on flux behaviours and biofilm formation potential. The surface properties of membrane coated with vanillin were changed tremendously compared to those with EGCG. As a result, the flux was reduced substantially. The biofilm formation seems hindered with EGCG coated membranes compared to the virgin membranes. More research is needed to optimize coating methods applicable to RO membranes and to enhance biofouling reduction.