• Title/Summary/Keyword: 바닥강성

Search Result 136, Processing Time 0.021 seconds

Simplified 2D Analysis for Suspension Bridges Subject to Wind Excitation (현수교 풍진동에 관한 2D 간단해석 및 변수연구)

  • Kim, Woo Seok;Lee, Jaeha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.463-470
    • /
    • 2013
  • In this paper, 2D simple analyses were performed in order to predict the large torsional oscillations in a suspension bridge based on Makenna and Tuama model(2001). The existing model(Makenna and Tuama, 2001) has shown unrealistic results as the wind speed increases and frequency decreases. Furthermore, resonance could not be simulated by the existing model. Therefore, in this study, new model was proposed with a consideration of the torsional resistance. The vertical and rotational behaviors of the deck in the suspension bridge were analyzed. Analysis results showed that at first vertical oscillations were observed and it was gradually transformed to the rotation oscillations. With the consideration of the torsional resistance, it was shown that vertical behavior were stabilized as time passed. However, the rotational behavior was not stabilized and was kept until the end of analysis. Beat periods decreased while the wind speed increased. The resonance of the rotational mode was dependent to the rotational resistance. Obtained results could be applied for the design of the suspension bridge under the wind load.

Structural Analysis Models to Develop Live Load Distribution Factors of Simply Supported Prestressed Concrete I-Girder Bridge (활하중 분배계수식 개발을 위한 I형 프리스트레스트 콘크리트 거더 교량의 구조해석 모델)

  • Lee, Hwan-Woo;Kim, Kwang-Yang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.1
    • /
    • pp.91-101
    • /
    • 2008
  • Structural analysis models to develop live load distribution factors of simply supported prestressed concrete I-girder bridge should have the precision of the analysis results as well as modeling simplicity. This is due to the numerous frequency of structural analysis needed while developing live load distribution factors. In this study, an appropriate structural analysis model is selected by comparing previous researchs studies and models used in practical design. Also, the influence by the flexural stiffness of barrier and diaphragm on the live load distribution had been analyzed through comparing the numerical analysis and experimental tests. As a result, the model that the eccentric girder and the barrier and diaphragm are connected to the deck plate was appropriate in satisfying both accuracy and simplicity for structural analysis of simply supported prestressed concrete I-girder bridge. However, the barrier was analyzed to have insignificant influence on the live load distribution in spite of its variation of stiffness. The eccentric diaphragm showed little influence at 25% or higher of flexural stiffness. From the results, a model that the girder is rigidly connected to the deck plate in consideration of the eccentricity, the barrier is ignored and the whole section of diaphragm is supposed to be valid without eccentricity is decided as the most appropriate structural model to develop the live load distribution factors of simply supported prestressed concrete I-girder bridge in this study.

Evaluation of Cracking Strength of Floating Floor System (뜬바닥구조의 균열강도 평가)

  • Lee, Jung-Yoon;Lee, Bum-Sik;Jun, Myoung-Hoon;Kim, Jong-Mun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This paper reports the test results of the floating floor system used to reduce the floor noise of apartment buildings. Recently, many soft resilient materials placing between the reinforced concrete slab and finishing mortar are used. The resilient material should not only reduce the floor impact sound vibration from the floor but also support the load on the floor. Thus, even if soft resilient materials satisfy the maximum limitation of light-weight impact sound and heavy-weight impact sound, these materials may not support the load on the floor. The experimental program involved conducting sixteen sound insulation floating floor specimens. Three main parameters were considered in the experimental investigation: resilient materials, loading location, and layers of floor. Experimental results indicated that the stiffness of resilient material significantly influenced on the structural behavior of floating floor system. In addition, the deflection of the floating concrete floor loaded at the side or coner of the specimen was greater than that of the floor loaded at the center of the specimen. However, the aerated concrete did not effect on the cracking strength of floating floor system.

Static Behavior of Large Stud Shear Connectors (대직경 스터드 전단연결재의 정적거동)

  • Lee, Pil Goo;Shim, Chang Su;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.611-620
    • /
    • 2003
  • Shear studs with a diameter of 19mm or 22mm are typically used in steel-concrete composite bridge. For the simplification of details in steel bridges, the convenience of removing concrete slab, and the efficient distribution of shear pockets for precast decks, large studs can be an excellent alternative. Through push-out tests on large stud shear connectors that transcend the limitation of current design codes, static behavior was investigated and comparisons with design equations performed. The shear stiffness of the connectors in elastic range and trilinear load-slip curves were proposed after shear tests on 25mm, 27mm, and 30mm studs. The ultimate slip capacity and ultimate strength of large studs were also evaluated, with the test results revealing conservative values for the design shear strength in Eurocode-4. For 30mm stud shear connectors, the welding quality and bearing capacity of concrete slab should be improved.

A Study on the Structural Behavior of LB-DECK Panel Considering Rebar-Arrangement in Site (현장 배근이 LB-DECK 패널의 구조거동에 미치는 영향)

  • Lho, Byeong-Cheol;Cho, Gyu-Dae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • The objective of this study is to verify whether the composite action is sufficiently strong to withstand at the interface and the structural behavior of LB-DECK panel with field concrete slab strengthened with main reinforcing bars. Static and fatigue tests are performed for LB-DECK panels with varied shapes and amounts of rebars, and the results are compared with those of field concrete panel(FCP). The test results indicate that the LB-DECK panel with 1.5 times of more rebars inside significantly increase the overall stiffness. LB-DECK penel usually shows on average 52.1 percent of improved stiffness compared with the FCP. The fatigue test results also show that the LB-DECK panel can withstand two-million cycles of repeated loads without any damage.

An Evaluation of Flexural Performance of Composite Beam with Ultra High Performance Concrete Deck and Inverted T-Shaped Steel Girder (초고강도 콘크리트 바닥판과 역T형 강재 합성보의 휨 성능 평가)

  • Yoo, Sung-Won;Joh, Chang-Bin;Choi, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.64-71
    • /
    • 2016
  • In this paper, when the composite beam is made with UHPC deck and steel girder, the steel girder takes the form of the inverted-T shape without top flange because of high strength and stiffness of UHPC deck. There is no evaluation by experiment and analysis about the shear connector behavior on the web of steel girder and flexural behavior of inverted-T shape composite beam. By this reason, this study compares between experiment and analysis by using tension softening model of UHPC on the basis of flexural test results of 16 members considering compressive strength of UHPC, spacing of stud and thickness of deck as variables. The results of tensile strength of UHPC by inverse analysis were 6.57 MPa(in case of 120 MPa) and 9.57 MPa(in case of 150 MPa). In case of the test members with small stud spacing, the results of analysis and test were close clearly, and the test members with thick deck and low UHPC compressive strength also similar, but effects were small. As it compared between analysis and experiment totally, the results of analysis and experiment agree well. So the tension softening model of UHPC is reasonably reflected on the real behavior of composite beam of UHPC.

Stray Electric Field Energy Harvesting for Power Supply of Ubiquitous Sensor Network (유비쿼터스 무선 센서 네트워크의 전력공급을 위한 표유전계에너지 하베스팅 기술 연구)

  • Chang, Keun-Su;Kang, Sung-Muk;Park, Kyoung-Jin;Shin, Seung-Hwan;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1310-1311
    • /
    • 2011
  • 본 논문에서는 신개념의 에너지 하베스팅 기술로서 전력선의 표유전계에너지 하베스팅을 제안하였고, 저전력 무선 센서노드에 전력공급이 가능함을 실험적으로 확인하였다. 전류가 흐르지 않는 무부하 상태의 220 V 전력선에 20 cm 길이의 알루미늄 포일을 감아서 하베스팅 할 때, 하베스터 회로의 접지가 220 V 전력선의 접지선에 연결되어 있는 경우, 수집 가능한 평균전류는 900 nA, 연구실 콘크리트 바닥에 접지되어 있을 경우, 700 nA의 평균전류를 얻을 수 있음을 확인하였다. 콘크리트 바닥에 접지되어 있는 하베스터 회로의 경우 220 V 전력선으로부터 접지선을 따로 빼 낼 필요가 없기 때문에 충분히 실용적이며 알루미늄 포일의 길이를 60 cm로 느리면 약 2분 만에 저전력 무선 센서노드 구동을 위해 필요한 에너지인 약 2 mJ 만큼 하베스팅이 가능하다. 본 기술을 적용하면 유비쿼터스 센서 네트워크의 전력을 공급할 수 있을 것으로 사료된다.

  • PDF

Behavior of Steel Box Girder Bridge According to the Placing Sequences of Concrete Slab (I) (강합성 상자형 교량의 바닥판 타설에 따른 거동 연구(I) - 해석모델 및 현장실험 -)

  • Kwak, Hyo Gyoung;Seo, Young Jae;Jung, Chan Mook;Park, Young Ha
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.123-131
    • /
    • 2000
  • In this study, both experimental and analytical study for behavior of the existing composite steel box girder bridges, constructed along with the procedure of continuous placing slab, are conducted to establish the validity of the proposed model. The layer approach is adopted to determine the equilibrium condition in a section to consider the different material properties and concrete cracking across the sectional depth, and the beam element stiffness is constructed on the basis of the assumed displacement field formulation and the 3-points Gaussian Integration. In addition, the effects of creep and shrinkage of concrete for time-dependent behavior of the bridge are taken into consideration. Finally, both analytical and experimental results are compared.

  • PDF

Ride Quality Analysis Using Seated Human Vibration Modeling (시트-인체 진동 모델링을 이용한 승차감 해석)

  • Kang, Ju Seok
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.3
    • /
    • pp.194-202
    • /
    • 2015
  • In this paper, dynamic modeling with viscoelastic properties of a human body resting on a seat is presented to quantitatively analyze ride quality of passengers exposed to vertical vibrations. In describing the motions of a seated body, a 5 degree-of-freedom multibody model from the literature is investigated. The viscoelastic characteristics of seats used in railway vehicles are mathematically formulated with nonlinear stiffness characteristics and convolution integrals representing time delay terms. Transfer functions for the floor input are investigated and it is found that these are different in accordance with the input magnitude due to nonlinear characteristics of the seat. Measured floor input at the railway vehicle is used to analyze realistic human vibration characteristics. Frequency weighted RMS acceleration values are calculated and the effects of the seat design parameters on the frequency weighted RMS acceleration values are presented.

Design of Ground Floor Slab According to the Method for Evaluating the Tensile Performance of Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트 인장성능 평가방법에 따른 지반 바닥슬래브의 설계)

  • Lee, Jong-Han;Cho, Baik-Soon;Cho, Chang-Oh
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.95-104
    • /
    • 2016
  • Flexural strength of concrete ground slab reinforced with steel fiber is evaluated using the equivalent flexural strength ratio of steel fiber reinforced concrete based on the yield line theory. Recently, the European standard specifies that the tensile performance of the steel fiber reinforced concrete be evaluated directly from the residual flexural strength after the cracking of concrete. Thus, in the study, an experiment was carried out to evaluate the conventional equivalent flexural strength ratio and the residual flexural strength of the steel fiber reinforced concrete. Then the design flexural strength was investigated according to the location of a point load, based on the ratio of the radius of contact area of the load to the radius of relative stiffness. Design flexural capacity obtained from ACI 360R-10 was smaller than that from TR 34 (2003 & 2013). In addition, TR 34 (2013), which evaluates the design flexural capacity based on the residual flexural strength, showed slightly smaller value than TR 34 (2003).