• Title/Summary/Keyword: 민감도 측정

Search Result 1,700, Processing Time 0.03 seconds

Magnetic Field Analysis Due to the Remanent Magnetization Distributed on a Ferromagnetic Thin Plate by using Equivalent Magnetic Models and Material Sensitivity (등가 자기모델과 매질민감도법을 이용한 강자성체 판에 분포하는 영구자화에 기인한 자기장 신호분석)

  • Jeung, Gi-Woo;Kim, Dong-Wook;Kim, Dong-Hun;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.100-105
    • /
    • 2010
  • For predicting magnetic signals due to the remanent magnetization distributed on a ferromagnetic ship hull, this paper presents an efficient methodology for solving inverse problems, where the material sensitivity analysis based on the continuum mechanics is combined with the equivalent magnetic models. To achieve this, the 3D magnetic charge model and the magnetic dipole moment model are introduced and material sensitivity formulae applicable to each equivalent model are derived. The formulae offer the first-order gradient information of an objective function with respect to the variation of the magnetic charge or magnetic dipole and so an optimal solution can be easily obtained regardless of the number of design variables. To validate the proposed method, the numerical results are comparison with the real measurements of a mock-up model.

Generation of Corporate Risk Contents of Small Firms and Large Firms Using Financial Data for Enhancing International Competitiveness (국제경쟁력 강화를 위한 중소규모기업과 대기업간 부실예측 콘텐츠)

  • Kim, Young-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.123-130
    • /
    • 2007
  • The purpose of this paper is to capture risk profiles of smaller-sized Korean firms $vis-{\grave{a}}-vis$ larger-sized firms during the Asian financial crisis. For this purpose, risk profiles are provided by estimating expected default risks and by tracking how these have changed during this period with respect to their magnitude, volatility, and sensitivity measures. Methodology used in this study employs the Black-Scholes-Merton model for producing estimates of default risks. And the conventional trans-log function is utilized for obtaining sensitivity measures of the estimated default risks. According to empirical evidence obtained here, it is revealed that contractions of corporate loans associated with IMF austerity policy was the main factor responsible for the drastic change in the default risk profile of Korean firms after occurrence of the Asian financial crisis.

Effects of Gold Nanoparticles on eggs and tadpoles of Rana dybowskii (금나노 물질이 북방산개구리에 미치는 영향)

  • Kim, Eun Ji;Ko, Weon Bae;Han, Eul;Kim, Ho Jin;Ko, Jeong Won;Chung, Hoon
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.407-413
    • /
    • 2015
  • As the number of applications containing nanomaterials increase, aquatic ecosystem exposure to nanoparticles (NPs) is unavoidable. In this study, we carried out toxicity assessment to Au-nanoparticles(NPs) of Rana dybowskii eggs and tadpoles. Toxicity was recorded hatching rate, body condition(Snout-tail length, STL), and behavioral sensitivity. Behavioral sensitivity was analyzed to anti-predator behavior using Ethovision XT 9. Au-NPs did not show any toxicity of hatching rate and STL. But, Tadpoles exposed to Au-NPs decrease behavioral sensitivity of stimuli. This study has value of environmental toxicity evaluation because these results show the new way of toxicity assessment.

Ultrasensitive Crack-based Mechanosensor Inspired by Spider's Sensory Organ (거미의 감각기관을 모사한 초민감 균열기반 진동압력센서)

  • Suyoun Oh;Tae-il Kim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Spiders detect even tiny vibrations through their vibrational sensory organs. Leveraging their exceptional vibration sensing abilities, they can detect vibrations caused by prey or predators to plan attacks or perceive threats, utilizing them for survival. This paper introduces a nanoscale crack-based sensor mimicking the spider's sensory organ. Inspired by the slit sensory organ used by spiders to detect vibrations, the sensor with the cracks detects vibrations and pressure with high sensitivity. By controlling the depth of these cracks, they developed a sensor capable of detecting external mechanical signals with remarkable sensitivity. This sensor achieves a gauge factor of 16,000 at 2% strain with an applied tensile stress of 10 N. With high signal-to-noise ratio, it accurately recognizes desired vibrations, as confirmed through various evaluations of external force and biological signals (speech pattern, heart rate, etc.). This underscores the potential of utilizing biomimetic technology for the development of new sensors and their application across diverse industrial fields.

Development of early diagnosis system for the detection of diabetic foot using photoplethysmograph (PPG를 이용한 당뇨병 환자의 족부질환의 조기진단 시스템 개발)

  • Kim Jin-Tae;Kim Sung-Woo;Hong Hyun-Ki;Im Jae-Joong;Kim Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.60-66
    • /
    • 2006
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to finger blood flow using photoplethysmography(PPG) and Laser Doppler(LD). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of 50 neuropathic diabetes($0.96{\pm}0.20$) was significantly higher than that of 64 normal person($0.46{\pm}0.15$)(p<0.000). It also showed that toe temperature of neuropathic diabetes($30.5{\pm}1.4^{\circ}C$) was significantly higher than that of normal group($29.3{\pm}2.0^{\circ}C$)(p<0.000). The optimal boundary value of the blood flow ratio was found to be 0.678 and the sensitivity and specificity of this proposed method resulted in 95.3% and 95.3% respectively. Lastly, there were no neuropathic diabetes whose temperature difference between finger and toe was higher than $4.5\;^{\circ}C$.

A Study on Method for Screening of Hypercalciuria in Children (소아에서 소변 Na/K 비를 통한 칼슘 배설량 예측)

  • Ko Han Seong;Choi Jeong Hoon;Choi Byoung Min;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kim Soon Kyum
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.11-16
    • /
    • 2000
  • Purpose. Urinary calcium excretion using a 24-hr urine colledtion has been used for the diagnosis of hypercalciuria up to now. But It takes a lot of time and costs much. We have investigated on a more simple method for screening of hypercalciuria in children. Methods: We had retrospectively analyzed sodium, potassium, calcium and creatinine in spot urine of eighty-four patients with urinary symptoms from May 1998 to July 1998 in Korea university Guro hospital and compared the urinary Ca/Cr ratio with the Nin ratio. Using a urinary Nan ratio >2.68 as a cutoff value in predicting the occurrence of hypercalciuria, we measured its sensitivity, specificity, positive predictive value and the negative predictive value. Results: A direct relationship was found between urinary Na/K and Ca/Cr ratio (r=0.496, P<0.001, Ca/Cr : Na/K x 0.0167+0.061). Using a urinary Na/K ratio >2.68 as a cutoff value in predicting the occurrence of hypercalciuria, its sensitivity was found to be $100\%$ and its specificity $54.5\%$. The positive predictive value was $37.5\%$ and the negative predictive value $100\%$. Conclusions : Spot urine Na/K ratio is a valuable test for the screening of hypercalciuria in children.

  • PDF

A Study on the Extraction of Psychological Distance Embedded in Company's SNS Messages Using Machine Learning (머신 러닝을 활용한 회사 SNS 메시지에 내포된 심리적 거리 추출 연구)

  • Seongwon Lee;Jin Hyuk Kim
    • Information Systems Review
    • /
    • v.21 no.1
    • /
    • pp.23-38
    • /
    • 2019
  • The social network service (SNS) is one of the important marketing channels, so many companies actively exploit SNSs by posting SNS messages with appropriate content and style for their customers. In this paper, we focused on the psychological distances embedded in the SNS messages and developed a method to measure the psychological distance in SNS message by mixing a traditional content analysis, natural language processing (NLP), and machine learning. Through a traditional content analysis by human coding, the psychological distance was extracted from the SNS message, and these coding results were used for input data for NLP and machine learning. With NLP, word embedding was executed and Bag of Word was created. The Support Vector Machine, one of machine learning techniques was performed to train and test the psychological distance in SNS message. As a result, sensitivity and precision of SVM prediction were significantly low because of the extreme skewness of dataset. We improved the performance of SVM by balancing the ratio of data by upsampling technique and using data coded with the same value in first content analysis. All performance index was more than 70%, which showed that psychological distance can be measured well.

Ascitic Fluid Analysis for the Differentiation of Malignancy-Related and Nonmalignant Ascites (악성 복수와 비악성 복수의 감별을 위한 복수액 분석)

  • Lee, Eun-Young;Kim, Byeoung-Deok;Choi, Jae-Hyuk;Lee, Sang-Yeop;Ryu, Hun-Mo;Lee, Kyung-Hee;Hyun, Myung-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.1
    • /
    • pp.76-84
    • /
    • 1999
  • The differentiation between malignancy-related ascites(MRA) and non-malignant ascites (NMA) is important for further diagnostic and therapeutic purposes. Although many parameters were investigated, none has provided a complete distinction between MRA and NMA. We investigated several ascitic fluid parameters to determine the differential power, and to differentiate malignant-related from nonmalignant-related ascites with a sequence of sensitive parameters followed by specific parameters. For the present study, 80 patients with ascites were divided into two groups: MRA and NMA, The MRA group was consisted of 27 patients with proven malignancy by image study, biopsy, and follow up: 21 of these patients had peritoneal carcinomatosis, but the remaining 6 showed no evidence of peritoneal carcinomatosis. The NMA group was consisted of 53 patients with no evidence of malignancy: among these patients, one had SLE, and others had liver cirrhosis, The samples of blood and ascites were obtained simultaneously, and then the levels of ascites cholesterol, CEA. protein and LDH, cytology, albumin gradient, ascites/serum concen-tration ratios of LDH(LDH A/S), and ascites/serum concentration ratios of protein(protein A/S) were measured. Applying cut-off limits for determined parameters, we estimated the diagnostic efficacy of each parameter, Among the eight parameters investigated, ascites fluid cholesterol yielded the best sensitive value of 93%(cut-off value 30mg/dl), and cytologic examination and the protein A/S(cut-off value 0.5) showed the most specific value of 100% and 96%, respectively. Based on the above results, the diagnostic sequence with cholesterol as a sensitive parameter followed by the combination of cytologic examination and protein A/S as specific parameters, was tested in 80 patients. This diagnostic sequence identified 81.5% of patients with malignancy, and all patients with peritoneal carcinomatosis were classified as malignancy-related ascites. In spite of many limitations, this proposed diagnostic sequence may permit a cost-effective and simple differentiation of malignancy-related ascites from nonmalignant ascites.

  • PDF

Assessment of tactile acuity by two-point discrimination and grating resolution in blind and deaf humans (시각 장애우와 청각 장애우에서 두점식별력과 격자해상능을 이용한 촉각인지능평가)

  • Park, Jin-Hee;Ryoo, Hyun-Kwang;Kim, Na-Ri;Choi, Myoung-Ae;Kim, Min-Sun;Park, Byung-Rim;Kang, Dae-Im
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.537-544
    • /
    • 2011
  • Tactile acuity was assessed in groups of control, blind, deaf, and blind caused by complication to investigate the effective tactile stimuli on tactile sensory substitution studies when tactile display is applied to persons with sensory loss of vision or hearing. Two-point discrimination and grating resolution were assessed by compass and JVP dome, respectively, in the hand, arm, neck, lumbar, and knee. In two-point discrimination by compass, control group showed the highest sensitivity in fingers among assessed body areas but did not show any significant difference between male and female. Blind group and deaf group compared to control group did not show any significant difference in fingers but showed lower sensitivity in arm and knee. In grating resolution by JVP dome, control group did not show any significant difference among five fingers as well as between male and female. Blind group showed higher sensitivity in five fingers compared to control group, but deaf group did not show any significant difference from control group. Blind caused by complication group showed lower sensitivity in two-point discrimination and grating resolution compared to control group and blind group. These results suggest that the body area and method of tactile stimulation, and difference in tactile acuity depending on underlying disease of sensory loss should be considered when tactile display is applied for sensory substitution.

  • PDF

Polarization-Maintaining Photonic-Crystal-Fiber-based Polarimetric Strain Sensor with a Short Sensing Head (짧은 센서부를 가진 편광유지 광자결정 광섬유 기반 편광 간섭형 스트레인 센서)

  • Noh, Tae Kyu;Lee, Yong Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.3
    • /
    • pp.131-136
    • /
    • 2014
  • In this paper we have implemented a temperature-insensitive polarimetric fiber strain sensor based on a Sagnac birefringence interferometer composed of a short polarization-maintaining photonic crystal fiber (PM-PCF), a 3-dB fiber coupler, and polarization controllers. The PM-PCF used as a sensor head was 2 cm long, which is the shortest length for a sensing element compared to other polarimetric fiber strain sensors using a PM-PCF. The proposed sensor showed a strain sensitivity of ${\sim}0.87pm/{\mu}{\varepsilon}$ with a strain measurement range from 0 to $8m{\varepsilon}$. The temperature sensitivity was also investigated and measured as approximately $-12pm/^{\circ}C$, when ambient temperature changed from 30 to $100^{\circ}C$. This temperature sensitivity is about 82 times smaller than that of conventional polarization-maintaining fiber (approximately $-990pm/^{\circ}C$). In particular, from a practical perspective we have experimentally and theoretically confirmed that the wavelength selected for the indicator dip location does not make a significant difference in the strain sensitivity.