• Title/Summary/Keyword: 민감도 측정

Search Result 1,695, Processing Time 0.032 seconds

Development of Membrane Strip Assay System for Lipoprotein Cholesterol (Membrane strip을 이용한 지질단백질 Cholesterol 측정시스템의 개발)

  • 신인수;백세환
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.140-150
    • /
    • 1996
  • To develop a home-version assay system for plasma lipoprotein cholesterol, variables that can control the assay performance were optimized. The system was constructcd by using two major components: nitrocellulose membrane strip with immobilized enzymes (cholesterol esterase, cholesterol oxidase, and horseradish peroxidase); and sample carrier solution containing non-ionic detergent (Triton X-100) and chromogen (3,3'-diaminobenzidine). Once a sample combined with the carrier was absorbed from the bottom of the strip, cholesterol was delivered by capillary action to the immobilized enzymes and a sequential reactions took place. In the final reaction, the chromogen was oxidized and then generated a color as signal that was proportional to the concentration of cholesterol. The signal intensity was enhanced by optimizing conditions for the immobilization of enzymes and the chemical composition of carriel. Under these conditions, a dose-response curve was obtained and revealed a high sensitivity enough to measure the cholesterol in blood.

  • PDF

단일 밴드 중적외선 영상을 이용한 표면온도 추정 방법 연구

  • Park, Uk;Lee, Yun-Gyeong;Won, Jung-Seon;Lee, Seung-Geun;Kim, Jong-Min
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • Mid-Infrared (MIR) 영상은 화산 활동 및 산불로 인한 재난관측, 지표물질 관측, 해수 온도 측정과 같은 분야들에서 사용되고 있다. 그러나 MIR영역은 지표의 복사율과 대기의 영향으로 인한 변화가 매우 심하고, 낮 영상의 경우 태양 복사량에 의한 영향도 고려해야 하는 어려움이 있다. 따라서 단일밴드인 MIR영상을 이용하여 표면온도를 얻기 위해서는 영상이 취득된 시간과 장소에서 관측된 태양 복사량 및 여러 가지 대기 변수가 필요하다. 본 연구의 목적은 기존의 MIR 영상 연구가 다중밴드를 기반으로 한 것과 달리 단일 밴드의 영상을 이용하여 표면온도를 측정하는데 있다. 이를 위하여 MODIS MIR 영상을 대상으로 MODTRAN을 사용하여 MIR 영역의 대기보정 기법을 적용 한 뒤 복사전달 모델을 이용하여 지표의 복사량을 측정하였다. 획득된 지표온도 영상의 정밀도를 측정하기 위해서 기존의 온도 알고리즘인 split-window algorithm에 의해 얻어진 해수온도 영상과의 비교를 통하여 오차 원인에 대해 분석을 실시하였다. 그 결과 낮 영상의 경우 -4.19${\pm}$1.19$^{\circ}C$ 정도의 온도 차가 났으며, 밤 영상의 경우 0.5$^{\pm}C$0.39$^{\circ}C$ 정도로 비교적 좋은 결과를 보였다. 이는 낮 영상의 경우 지표의 복사율에 대한 온도의 민감도가 매우 높기 때문에 높은 오차가 발생하지만, 밤 영상의 경우 태양빛에 의한 영향이 없으므로 좋은 결과를 나타내기 때문이다. 따라서 단일밴드 MIR영상을 이용한 지표온도 추정 시 대기에 의한 영향보다 지표 복사율에 의한 영향이 높다고 추정할 수 있다.

  • PDF

Noncontact Laser Ultrasonic Imaging for Automated Damage Detection (자동화 손상 검색을 위한 비접촉식 레이저 초음파 영상화)

  • Park, Byeong-Jin;An, Yun-Kyu;Sohn, Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.40-43
    • /
    • 2011
  • 최근, 레이저 초음파 영상화 기법은 구조물의 비접촉식 손상 진단을 위해 널리 연구되고 있다. 초음파 영상화 기법의 가장 큰 장점은 비접촉식으로 구조물의 손상을 진단할 수 있고, 가진 및 측정 지점을 자유로이 이동할 수 있다는 점이다. 따라서 이는 고온이나 동적상태의 구조물에 적용이 가능하며, 시간과 공간상의 충분한 데이터를 획득할 수 있으므로 역문제 (Inverse problem)를 해결할 필요 없이 완전한 초음파의 전파 형상을 얻을 수 있다. 지난 연구들에서는 충분한 가진력 혹은 측정 민감도를 확보하기 위해 가진 레이저와 부착형 센서의 조합이나 부착형 가진 트렌스듀서와 센싱 레이저의 조합으로 초음파 영상을 획득하고자 하였다. 하지만 이들 조합은 가진 혹은 측정 지점이 구조물에 부착되어 있어 완전한 비접촉식 기법을 구현하지 못하였다. 이를 극복하고자 레이저와 EMAT 센서 등의 조합이 시도되어 왔으나, 이 또한 EMAT 센서의 적용 거리에 따른 한계점을 지니고 있다. 본 연구에서는 가진 레이저 (Nd:Yag)의 스캐닝을 통해 다양한 가진 점에서 발생된 초음파가 탄성체 구조물을 통해 전파되고, 이를 센싱 레이저 (Laser Doppler Vibrometer)를 이용하여 측정함으로써 비접촉식 초음파 영상화를 구현하였다. 나아가, 정상파 필터(Standing-wave filter)를 이용하여 구현된 초음파 영상으로부터 손상 영향만 검출해 내는 기법을 개발했다. 개발된 기법은 복합재 시편의 층간박리 (Delamination) 진단을 통해 검증하였다.

  • PDF

Automatic defect detection using intensity and shape information in industrial CT (산업용 CT 영상에서 밝기값 및 형태 정보를 이용한 기공 결함 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06c
    • /
    • pp.415-417
    • /
    • 2012
  • 본 논문에서는 산업용 CT 영상에서 다중 해상도 기반의 밝기값 정보와 형태 정보를 이용하여 내부 기공결함을 정확하고 빠르게 검출하는 기법을 제안한다. 첫째, 대용량 CT 데이터에서 계산량을 줄이기 위하여 1/2 해상도로 변환 후 관심영역을 자동 산정하고, 링 또는 금속 인공물 등의 잡음을 제거하기 위해 비등방성 확산 필터링을 수행한다. 둘째, 기공 결함 후보군을 검출하기 위해 밝기값 기반의 결함 검출 기법을 제안한다. 셋째, 결함 검출의 민감도를 향상시키기 위해 형태 정보를 이용한 기공 결함 검출 기법을 제안한다. 넷째, 수행시간 가속화를 위하여 다중 해상도 영상 처리 및 Open MP를 적용한다. 제안방법의 평가를 위하여 육안평가와 정확성 평가, 수행시간을 측정하였다. 정확성 평가는 실제 기공 결함과 제안방법 적용 후 결함 간 중복 픽셀 수로 측정하였다. 실험 결과 평균 중복 픽셀 비율은 91%로 측정되었고, 가장 큰 비율은 99%, 가장 작은 비율은 80%로 측정되었다. 다중 해상도 기법 및 Open MP를 적용함으로써 해상도 데이터 수행시간보다 90% 가속화되었다.

Proprioception associated with sub-clinical neck pain (경미한 경부 통증과 고유수용성 감각)

  • Lee, Hae-jung;Nicholoson, Leslie L.;Adams, Roger D.;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.3 no.1
    • /
    • pp.55-66
    • /
    • 2005
  • 목적 : 본 연구는 경미한 경부 통증을 가진 대상자의 경부 운동감각과 경부 통증과 기능에 대하여 조사하였다. 방법 : 본 연구의 대상자는 자발적으로 참여한 81명의 (나이 18-30세, 평균 23.2) 건강한 대학생으로 구성되었으며, 측정은 경부운동감각과 통증 및 기능에 대하여 측정하였다. 경부운동감각은 편안히 앉은 자세에서, 경부 후인과 좌우 회전의 중간 관절 범위에서 대상자의 두부에 착용하지 않는 기구를 사용하여 측정하였다. 경부 통증과 기능은 가장 흔히 쓰이는 4가지 설문지를 한국어로 번역하고 문화적으로 적응하는 과정을 거쳐 사용하였다. 결과 : 대상자들을 경부 통증 빈도에 따라 세 집단으로 (통증 없음, 월별, 주별) 구분하였다. 각 집단간에는 4가지 설문지로 조사한 경부통증과 기능에는 차이를 보이지 않았으나, 경부운동감각은 통증 빈도가 높을수록 더 민감하게 나타났다 결론 : 경부 운동감각은 편안히 앉은 자세에서 경부 후인과 좌 우회전의 중간 관절범위에서 측정하였으며, 경미한 경부 통증 빈도가 높을수록 경부 운동감각은 더 민감하게 나타났다.

  • PDF

Ellipsometric Expressions for a Near-normal-incidence Ellipsometer with the Polarizer-compensator-sample-compensator-analyzer Configuration (편광자-보정기-시료-보정기-검광자 배치를 가지는 준 수직입사 타원계의 타원식)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.172-179
    • /
    • 2021
  • A near-normal-incidence ellipsometer (NNIE) is suggested as an optical critical dimension (OCD) measurement system that is highly sensitive to the bottom defect of a sample with high-aspect-ratio structured patterns. Incident light passes through a polarizer and a phase retarder in sequence, and the reflected light from the sample also passes through them, but in reverse order. The operating principle of this NNIE, where a single polarizer and a single phase retarder are shared by the incident and reflected light, is studied, and a method to determine the ellipsometric constants from the measured intensities at proper combinations of the azimuthal angles of polarizer and retarder is presented.

Research on Ultrasound System and Measurement Technology for Mechanical Defect Monitoring of Human-inserted Artificial Medical Devices (인체 삽입형 인공 의료 기구물 기계적 결함 모니터링을 위한 초음파 시스템 및 계측 기술 연구)

  • Youn, Sangyeon;Lee, Moonhwan;Hwang, Jae Youn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.470-473
    • /
    • 2021
  • In this study, we developed the biometric ultrasound transducer, residual thickness measurement algorithm and optimized ultrasound operation methods to diagnose precise conditions of implanted medical prosthetic material inserted during total hip artificial joint replacement. In detail, ultrasound transducers having 8 MHz and 20 MHz center frequencies with similar sensitivity and bandwidth were fabricated to measure various thicknesses of commercial polyethylene-based artificial hip liners, resulting in a comparative analysis of signal-to-noise ratio and axial resolution to conduct an optimization study of ultrasound operations in vivo.

  • PDF

Physical property evolution along gas hydrate saturation for various grain size distribution (다양한 입도분포에서의 하이드레이트 함유량에 따른 물성 변화 양상 연구)

  • Jung, Jaewoong;Lee, Jaehyung;Lee, Joo Yong;Lee, Minhui;Lee, Donggun;Kim, Sejoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.149-149
    • /
    • 2011
  • 청정 에너지원으로 높은 잠재력을 가지고 있는 가스하이드레이트는 상업적 기술개발이 미확보된 상태임에도, 우리나라에서 부존이 직접적으로 확인되었기 때문에 에너지원으로서 그 중요성이 부각되고 있다. 현재 전세계적으로 가스하이드레이트 개발 및 생산에 관한 연구가 활발히 진행되고 있으며 이에 대한 기초자료로서 가스하이드레이트가 함유된 퇴적층의 물성자료가 필요하다. 이에 따라 본 연구에서는 입도 분포별 총 5가지의 미고결 시료를 대상으로 투과도, p파속도, 전기비저항 측정을 수행하였다. 연구에 사용된 미고결 시료는 Hama#5($774{\mu}m$), #6($485{\mu}m$), #7($258{\mu}m$), #8($106{\mu}m$) 4가지와 Hama#6과 Hama#7을 1:1($371{\mu}m$)로 혼합하여 사용하였다. 실험에 사용된 장비는 가스하이드레이트를 인공적으로 생성시키기 위해 퇴적층을 모사할 수 있는 고압셀과 자료획득장비, 유체 주입장비, 온도 유지장비이다. 또한 투과도 측정에는 차압계, 전기비저항 측정에 RLC meter, p파속도 측정에 음파 송수신장비를 사용하여 각각의 물성을 측정하였다. 실험과정을 단계별로 요약하면 먼저 시료를 고압셀에 충진한 뒤 주입된 물의 양으로부터 공극률을 측정하고, 절대 투수계수를 측정하였다. 그 후, 메탄가스를 주입하여 퇴적층 내 수포화도(water saturation)를 잔류상태(irreducible saturation)로 유지시키고 메탄가스를 추가적으로 주입하여 원하는 압력까지 가압한 뒤 온도를 $1^{\circ}C$로 낮추었다. 가스하이드레이트의 생성은 급격한 압력강하로부터 알 수 있다. 최종적으로 가스하이트레이트가 함유된 퇴적층의 상대 투수계수를 측정하기 위해 메탄가스를 주입하였고 각각의 측정장비를 통해 전기비저항 및 p파 속도를 측정하였다.$V_g$, $V_h$, $V_w$, $V_ss$는 각각 가스의 부피, 하이드레이트의 부피, 물의 부피, 모래의 부피이다. 또한 수포화도, $S_w=\frac{V_w}{V_v}$이며 하이드레이트 포화도, $S_h=\frac{V_w}{V_v}$, 가스 포화도, $S_g=\frac{V_g}{V_v}$로 정의된다. 본 실험의 결과 투과도는 가스의 부피비, $\frac{V_g}{V}=nS_g$에 민감한 반응을 보였으며, 비저항은 공극수의 부피비, $\frac{V_w}{V}=nS_w$에 민감한 반응을 보였다. 또한 p파 속도는 고체의 부피비, $\frac{V_s+V_h}{V}=n(1-S_h)$에 민감한 반응을 보였다. 이러한 실험의 결과는 가스하이드레이트 개발, 생산 연구에 있어 기초 물성자료로 활용되는데 도움을 줄 것이다.

  • PDF

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

Novel Detection Algorithm of The Upstroke of Pulse Waveform for Continuously Varying Contact Pressure Method (연속 가압방식의 맥파 측정방법을 위한 시작점 검출 알고리즘 개발)

  • Bae, Jang-Han;Jeon, Young-Ju;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.46-54
    • /
    • 2012
  • We propose a continuously varying contact pressure(CVCP)-adaptive feature extraction algorithm for pulse diagnostic analysis. The CVCP method measures the pulse waveform with continuously increasing contact pressure(CP). This method offer a high resolution signal of the pulse waveform amplitude(PWA) as a function of the contact pressure. Therefore it enables us to overcome the limitation of commercially available pulse-taking devices whose analysis rely on a few number of PWA-CP pairs. We show that an efficient feature extraction algorithm which covers the features of the CVCP-method can be developed by sequentially applying Fast Fourier Transform, peak detection by center-to-edges method, baseline drift removal, detection of the percussion wave upstroke by intersecting tangent method and detection of the analysis region. Finally, by a clinical study with 30 subjects, we show that our CVCP-adaptive feature extraction algorithm detected the upstroke with accuracy of 99.46% and sensitivity of 99.51%, which were about 4.82% and 2.46% increases respectively, compared to a conventional feature extraction method. The proposed CVCP method and the CVCP-adaptive feature extraction algorithm are expected to improve the accuracy in the pulse diagnostic algorithms such as floating/sunken pulse qualities and deficient/excess pulse qualities.