• Title/Summary/Keyword: 민감도 측정

Search Result 1,695, Processing Time 0.04 seconds

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1505-1510
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. The finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

Strain and Temperature Measurement using Transmission-type EFPI Optical Fiber Sensors (투과형 EFPI 광섬유 센서를 이용한 변형률 및 온도의 측정)

  • Kim, Sang-Hoon;Lee, Jung-Ju;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The extrinsic Fabry-Perot interferometric (EFPI) optical fiber sensor shows good sensitivity and resolution, and has many advantages over optical fiber sensors of other types. However, this EFPI optical fiber sensor has a disadvantage that the distinction of measuring directions is difficult due to the measurement method by using only fringe counting. In this paper, the transmission-type extrinsic Fabry-Perot interferometric (TEFPI) optical fiber sensor was developed, which has been improved by the additional function and whose measuring system is different from that of the conventional EFPI optical fiber sensor. Then the application result of the TEFPI optical fiber sensor to the strain and temperature measurement was explained in detail.

  • PDF

표면 다점 온도 측정을 이용한 용접 중 용융지 크기 추정

  • 원윤재;조형석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.223-227
    • /
    • 1993
  • 최근 생산성 향상을 위해 용접 자동화가 실용 분야, 특히 GMAW 공정에서 활발히 진행되고있다. 그러 나, 현 수준의 용접 자동화는 완전 자동화에는 이르지 못하고 단지 주어진 용접 조건과 용접 경로로 용 접을 실행하는 로보트 시스템의 채용으로 인간의 작업을 대체하는 정도이다. 이와 같은 로보트 시스템 을 이용한 자동화에 있어서는 예기치못한 공정의 변동에 대처하기 위한 공정 중 용접질 모니터링이 더욱 중요해지고 있다. 본 연구에서는 이 목적으로 표면의 다점 온도를 측정하여 이 중 한점의 온도와 이점 이점 부근의 온도 구배로써 용융지 크기 추정 지수를 구성하였다. 이 지수는 온도 변수들과 대응 용융지 크기 간에 다중 회귀 방법을 이용하여 최소 추정 오차가 발생하도록 설정된 수학적 모델이다. 제안된 지 수의 추정 성능을 평가하기 위해 용접 열전도 모델로 부터 얻은 용융지 크기와 표면 온도분포 data를 이용 하여 일련의 시뮬레이션 연구를 실시하였다. 이 과정에서 지수 구성 온도 변수들의 차수가 추정 성능에 미치는 영향과 온도 측정 위치에 따른 추정 성능의 민감도를 추정 오차와 오차 분산을 통해 분석하고, 지수를 사용하였을 때의 추정성능을 한점 온도를 이용하는 경우와 비교 평가하였다.

Stability and Accuracy of the Conversion Model of Open-Ended Coaxial Probe (개방 단말 동축선 프로브의 환산모델에 대한 안정성과 정확성)

  • Kim Yee-Jung;Jo Yu-Sun;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.33-39
    • /
    • 2005
  • Complex permittivities of material in a wide bandwidth are measured by using an open-ended coaxial probe. To obtain a confident complex permittivity profile, the accuracy of measured reflection coefficients and the stability of the conversion model should be guaranteed in advance. In this paper, the sensitivity of our conversion model is analyzed by employing two instruments with different uncertainties. And various factors effected on the accuracy of measured reflection coefficients are investigated in experiment.

Preliminary Study of IoT Module for Monitoring of Abnormal Respiratory Activity during Sleep (수면 중 비정상호흡 모니터링을 위한 IoT 모듈 사전연구)

  • Park, Sooji;Shin, Hangsik;Kim, Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1423-1424
    • /
    • 2015
  • 본 연구는 IoT 환경에서 수면 중 비정상호흡 모니터링을 위한 모듈개발 사전연구로, 베개 안에 삽입할 수 있는 가속도, 진동 측정 모듈을 제작하고, 측정된 신호를 기반으로 수면 중 발생하는 호흡활동을 관찰하는 것을 목적으로 한다. 이를 위하여 압전센서 및 3축 가속도 센서를 내장한 진동, 가속도 측정 모듈 프로토타입을 설계 및 제작하였으며, 파일럿 실험을 통하여 개발된 모듈의 동작을 확인하였다. 실험 결과 가속도 및 압전센서에서 획득된 신호에서 호흡성분이 검출되는 것을 확인하였으나, 샘플링율, 센서 민감도 설정에 따라 코골이 성분은 검출되지 않았다.

  • PDF

Tolerance Allocation Method for IR Optics Fabrication Using Monte-Carlo Simulation Based on Measured Reflective Eccentricity (편심측정 결과가 반영된 몬테카를로 시뮬레이션을 이용한 적외선 광학계 조립정렬 공차 할당 기법)

  • Yoo, Jae-Eun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • In this paper, a tolerance allocation method using Monte-Carlo simulation with measured reflective eccentricity for high-sensitive IR optics is proposed. During optics fabrication and alignment, reflective eccentricity was measured using an optical centration measurement instrument. A Monte-Carlo simulation was performed using measured eccentricity data, and it gives statistical estimated performance of the optics after fabrication. The validity of the proposed tolerance allocation method was verified comparing the estimated MTF result with the measured MTF result of the fabricated optics.

다양한 부유 고조화파 탐침법의 비교연구

  • Kim, Dong-Hwan;Lee, Hyo-Chang;Kim, Yu-Sin;Kim, Yeong-Do;Park, Il-Seo;Gang, Hyeon-Ju;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.580-580
    • /
    • 2013
  • 공정 플라즈마에서 사용할 수 없는 단일 랭뮤어 탐침법의 단점을 극복하기 위해서 부유 고조화파 탐침법이 개발되었고, 개선되어왔다. 다중 주파수를 인가하여 발생하는 고조화파 신호들 중 상호간섭주파수의 진폭을 이용하는 Sideband 방법과 원신호의 주파수 진폭을 이용하는 이중 주파수 방법이 있는데, 본 연구에서는 위와 같이 응용된 방법들과 기존의 부유 고조화파 탐침법의 장단점을 파악하고, 차이점을 규명하였다. 플라즈마 변수를 이끌어내기 위해 사용된 베셀함수의 민감도를 통해 특정 전자온도 영역에서의 각 방법들의 신뢰성을 비교해보았고, 측정값에서의 차이를 주파수 응답 특성 차이 및 전자 에너지 분포의 차이로 설명하였다. 이런 비교 연구를 통해 상황 별 적합한 측정 방법을 선택적 이용할 수 있을 뿐만 아니라, 이를 통해 측정하는 플라즈마 변수의 신뢰성을 향상시킬 수 있을 것으로 예상된다.

  • PDF

Design of null lenses for testing of hyperbolic surfaces (쌍곡면 측정 null 렌즈 설계)

  • 김연수;김병윤;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.352-355
    • /
    • 2001
  • A null lens is designed for testing the hyperbolic mirror which is the first mirror of the off-axis three mirror anastigmat(TMA) designed as a high resolution camera for remote sensing. To choose a better null lens system for the hyperbolic surface under test, both autostigmatic and mixed type null lenses are designed and analysed for sensitivity with respect to change of each surface parameter such as the radius of curvature and the thickness.

  • PDF

Fabrication and characteristics of Hybrid-type radiation detector using $HgI_2$ (혼합형 구조를 적용한 $HgI_2$ 기반의 방사선 센서 제작 및 특성)

  • Jang, K.Y.;Kang, H.G.;Lee, G.H.;Kim, S.Y.;Park, J.K.;Choi, H.K.;Nam, S.H.;Lim, J.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.460-463
    • /
    • 2004
  • 본 논문은 고에너지 방사선 검출을 위한 흔합형 구조의 방사선 센서를 제작, 반응 특성을 평가하였다. 먼저, 스크린 인쇄법을 이용하여 형광체 필름을 제작하였으며, 발광스펙트럼(PL, Photoluminescence) 및 잔광 시간(decay time) 측정을 통하여 형광체의 발광 특성을 조사하였다. 제작된 혼합구조의 방사선 센서는 $2{\mu}m$ 두께의 $HgI_2$$150{\mu}m$ 두께의 형광체 필름으로 제작되었으며, 면적은 $2\;cm\;{\times}\;2\;cm$이다. 방사선에 대한 전기적 검출 신호의 특성을 조사하기 위해 인가전압에 따른 암전류 및 방사선민감도, 선량에 따른 검출신호를 측정하였다. 측정결과, 제작된 $HgI_2$ 필름은 방사선에 의해 형광체에서 방출된 가시광 파장을 잘 흡수하였으며, 진단영역의 저에너지 방사선에 의해 직접 전기적 신호를 발생시켜 높은 방사선 민감도를 보였다. 뿐만 아니라, 인가전압에 대해 $10\;pA/mm^2$이하의 낮은 암전류를 가졌으며, 넓은 조사선량에서 우수한 선형성을 보였다.

  • PDF

Fabrication and Electrochemical Analysis of Back-gate FET Based on Graphene for O2 Gas Sensor

  • Kim, Jin-Hwan;Choe, Hyeon-Gwang;Kim, Jong-Yeol;Im, Gi-Hong;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.271-271
    • /
    • 2014
  • 본 연구에서는 최근 다양한 전자 소자로써의 연구가 진행되고 있는 그라핀을 SiO2/Si 기판 위에 전자빔 식각(Electron-Beam Lithography)을 이용하여 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자를 형성하고 가스 유입이 가능한 진공 Probe Measurement System을 이용하여 금속 전극과 그라핀 간의 접촉저항 (Rc) 및 길이가 다른 채널저항(Rch)를 구하고, 채널 길이, 가스 유량, 온도, 게이트 전압에 따른 I-V 변화를 측정함으로써, 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자의 가스 센서로서의 가능성을 연구하였다. 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자는 전자빔 식각(Electron-Beam Lithography)에 의해 패턴을 제작하고 Evaporator를 이용하여 전극을 증착 하였다. 소자의 소스 (Source)와 드레인 (Drain)은 TLM (Transfer Length Method)패턴을 이용하여 인접한 두 개의 전극간 범위를 변화시키는 형태로 제작함으로써 소스-드레인간 채널 길이가 다르게 하였다. 이 때 전극의 크기는 가로, 세로 각각 $20{\mu}m$, $40{\mu}m$이며 전극간 간격은 $20/30/40/50/60{\mu}m$로 서로 다르게 배열 하였다. 제작된 그라핀 소자는 진공 Probe Measurement System 내에서 게이트 전압(VG)를 변화시킴으로써 VG 변화에 따른 소자의 특성을 평가하였는데, mTorr 상태의 챔버 내로 O2 가스를 주입하여 그라핀의 Dangling bond 및 Defect site에 결합 된 가스로 인한 전기적 특성의 변화를 측정하고, 이 때 가스의 유량을 50 sccm에서 500 sccm 까지 변화시킴으로써 전기적 특성 변화를 측정하여 센서 소자의 민감도를 평가하였다. 또한, 서로 다르게 배열한 소스-드레인 간의 채널 길이로 인하여 채널과의 접촉 면적에 따른 센서 소자의 민감도 또한 평가할 수 있었다. 그리고 챔버 내 온도를 77 K에서 400 K까지 변화시킴으로써 온도에 따른 소자의 작동 범위를 확인하고 소자의 온도의존성을 평가하였다.

  • PDF