A Study of Critical Items and Related Standards on Designing for Passive Apartments (패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구)

  • Lee, Myoung-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

Characterization of metal-containing activated carbon derived from phenolic resin (페놀 수지로부터 유도된 금속이 함유된 활성탄의 특성화)

  • Oh, Won-Chun;Jang, Won-Cheoul;Kim, Bum-Soo
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.349-355
    • /
    • 2001
  • A series of micro- and mesoporous activated carbons were prepared from phenolic resin using a metal treated chemical activation methodology. $N_2$-adsorption data were used to characterize the surface properties of the produced activated carbons. Results of the surface properties and pore distribution analysis showed that phenolic resin can be successfully converted to micro- and mesoporous activated carbons with specific surface areas higher than $962.3m^2/g$. Activated carbons with porous structure were produced by controlling the amount of metal chlorides($CdCl_2$, $CuCl_2$). Pore evolvement was shown to be most effected by the incremental addition of metal chloride. From the thermodynamic DSC data, enthalpy formations(${\Delta}H$) of first endothermic reaction were increase with the incremental addition of metal chloride.

  • PDF

금속 핵연료와 HT9 피복관의 상호반응을 방지하기 위한 피복관 내면 도금 연구

  • Yeo, Seung-Hwan;Kim, Jun-Hwan;Kim, Seong-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.98.1-98.1
    • /
    • 2018
  • 소듐냉각 고속로 (SFR)는 원자력 발전의 가장 시급한 문제점으로 부각되고 있는 사용 후 핵연료를 재활용 하여 가동하는 원자로 이다. Generation IV로 명명되는 차세대 원자로 중에 하나로 국제 공동연구와 자체 연구를 통해 우리나라 고유의 기술이 축적되고 개발되고 있다. 현재 소듐냉각 고속로의 가장 큰 문제점 중의 하나는 금속핵연료와 피복관의 상호반응이다. 상호반응이 일어나면 공융현상을 일으켜 피복관의 녹는점이 낮아지고 피복관의 두께가 얇아져 원자로의 안전에 치명적인 위협이 된다. 이러한 문제를 해결하기 위해 전해도금 (electro-plating)을 활용하여 HT9 피복관 내면에 크롬을 도금하여 금속핵연료와 피복관의 상호반응을 억제하는 연구가 본 연구팀에서 진행되고 있다. 크롬과 전해도금을 코팅 물질과 코팅 방법으로 선정한 이유는 튜브 내면에 적용하기 용이하고 경제적인 코팅 방법이기 때문이다. 본 연구에서는 여러 가지 전해도금 인자 중 온도와 pulse 전류의 파형이 상호반응 방지 효과에 미치는 영향에 대하여 고찰하였다. 도금액의 온도를 $50{\sim}80^{\circ}C$, 전류 파형 중 on/off time을 1:1, 10:1, 1:10으로 하여 여러 HT9 시편을 도금하였고 모의 금속 핵연료 합금인 Ce-Nd와 확산 반응 실험을 수행하여 상호반응 방지 효과를 분석하였다. 광학현미경과 전자현미경을 이용한 미세구조 분석 결과 도금액의 온도가 $65^{\circ}C$ 이하인 시편에서는 미세균열이 심하게 발생하였고 그 균열을 통해서 물질이 확산하고 상호반응을 한다는 것이 관찰되었다. $65^{\circ}C$보다 높은 도금액의 온도에서 형성된 크롬막은 균열이 없고 상호반응 방지 효과가 좋은 것이 확인되었다. 특히 전류 파형의 on/off time이 1:1일 때 상호반응 방지 효과가 가장 좋은 것을 확인하였다. 이러한 결과는 크롬 전해도금의 코팅 조건이 상호반응 방지 효과에 매우 중요한 요인으로 작용한다는 것을 말해주고 있다.

  • PDF

Detection and Evaluation Technique of Hydrogen Attack (수소손상 검출과 평가기술)

  • Won, Soon-Ho;Hyun, Yang-Ki;Lee, Jong-O;Cho, Kyung-Shik;Lee, Jae-Do
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.32-37
    • /
    • 2002
  • The presence of hydrogen in industrial plants is a source of damage. Hydrogen attack is one such form of degradation and often causing large tube ruptures that necessitate an immediate shutdown. Hydrogen attack may reduce the fracture toughness as well as the strength of steels. This reduction is caused partially by the presence of cavities and microcracks at the grain boundaries. In the past several techniques have been used with limited results. This paper describes the application of an ultrasonic velocity and attenuation in hydrogen damage. Ultrasonic tests showed a decrease in wave velocity and an increase in attenuation. Such results demonstrate the potential for ultrasonic nondestructive testing to quantify damage. Based on this study, reliable recommendation is suggested to detect hydrogen attack.

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

Evaluation of Particulate Matter Removal Rate according to Filter Type and Thickness of Total Heat Exchanger in Apartment Houses (공동주택 전열교환기 필터종류 및 두께에 따른 미세먼지 제거율 평가)

  • Song, Yong-Woo
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.93-98
    • /
    • 2020
  • This study examined the particulate removal performance of three different types of air filters inside a heat exchanger. Of interest was the ability of each filter type in reducing the transmission of outdoor particulate matter of PM10 from entering an apartment while the heat exchanger was in operation. The study tested one commonly used medium filter (E11 grade) and two HEPA filters (H13 grade) of different thicknesses. Two different concentrations of particulate matter were used in the experiment to address different ambient air quality conditions in Korea, 32.75 ㎍/㎥ and 67.26 ㎍/㎥. Study results indicated that under the particulate matter concentration of 32.75 ㎍/㎥, all three filters were capable of removing more than 95% of the fine dust. However at a particulate matter concentration of 67.26 ㎍/㎥, the medium E11 grade filter was only able to remove about 90% of the particulates whereas the HEPA H13 grade filters were able to remove 95% or more of the particulates. The thicker HEPA filter (40T) was also more effective in removing particulates than the thinner HEPA filter (20T) by about 1.6 to 3 percentage points. Based on the findings of this study, it is recommended that HEPA filters of 20T thickness or greater be used during the high air pollution seasons of winter and spring in Korea while medium filters can be used during the other seasons to reduce outdoor air pollution transmission indoors.

Evaluating the Applicability of Activated Carbon-added Fiberboard Filters Fabricated with Lignocellulosic Fiber for the Reduction Equipment of Particulate Matter (리그노셀룰로오스 섬유 기반 활성탄-첨가 섬유판 필터의 미세먼지 저감장치용 적용가능성 평가)

  • Yang, In;So, Jae min;Hwang, Jeong Woo;Choi, Joon weon;Lee, Young-kyu;Choi, Wonsil;Oh, Seung Won;Moon, Myoung cheol
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.548-556
    • /
    • 2021
  • This study was conducted to investigate the applicability of lignocellulosic fiber and coconut shell activated carbon (CSA) for the production of a particulate matter (PM)-reducing air-filter as raw materials to solve the environmental problems of non-woven fabrics. CSA had a good potential to use as a raw material of air-filter for reducing volatile organic compounds as well as noxious metals, and reduction capability of the CSA was 5 times higher than that of wood fiber. Natural adhesives formulated with proteinaceous wastes mostly were applied successfully to fabricate air-filters with the shape of fiberboard. The air-filter fabricated with the minimum target density of 200 kg/m3 and the maximum CSA-content of 40 wt% in fiberboard had a good manageable strength. However, the fiberboard filters was required to make vent-holes for improving an air-permeability of the filters. Size of the CSA particles was adjusted to greater than 2 mesh with the consideration of strength and formability of the fiberboard. Three-layers fiberboard that only wood fiber and the mixture of wood fiber and CSA were formed in the surface and middle layers, respectively, was determined to the optimal condition for the production of air-filters. In addition, traditional Korean paper handmade from mulberry trees (TKP) showed a good PM-reducing property as an air-filter. It is concluded that air-filtering set composed of fiberboard with vent-holes and TKP instead of conventional air-filters made with non-woven fabrics can be used as a filter for reducing the concentrations of PM, VOC and noxious metals existed in indoor and outdoor spaces.

A Study on the Growth and Environments of Panax ginseng in the Different Forest Stands (I) (임상별 임간인삼의 생육과 최적환경에 관한 연구(I))

  • 우수영;이동섭
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.65-71
    • /
    • 2002
  • The best environments such as crown density, temperature, light intensity and humidity have to be identified because these factors are strongly related to the growth and several physiological characteristics. The purposes of this study are \circled1 to collect basic data fer growth, \circled2 to identify the best growth environments. to achieve these purposes, oak, pine and mixed forest stands have been selected in this study. forest ginseng seeds were sown in these forest four years ago. Several environmental and growth factors have been surveyed. In general, mean tree age, DBH and average height are 20-25 years old, 14-17 cm and 7-9 m, respectively. The growths of forest ginseng grown in oak stand are better than those of pine and mixed stands.

TWSC Estimation using GRACE Satellite Gravity Data (GRACE 인공위성 중력 자료를 이용한 수자원변화량(TWSC) 산정)

  • Kim, Joon-Soo;Lee, Sang-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.377-381
    • /
    • 2011
  • 지구는 지속적으로 변화하는 동력학적 시스템이며, 지표면 형상 및 지구 내부의 질량분포도 계속 변화하고 있다. 지구시스템의 질량재분배 과정에서 발생되는 밀도 차이는 중력장의 미세한 변이를 초래한다. 미 항공우주센터(NASA)와 독일 국립 항공우주연구센터(DLR)에서 공동으로 개발한 GRACE (Gravity Recovery And Climate Experiment) 인공위성은 지구의 중력장을 측정하는 위성으로, 2002년부터 현재까지 9년 동안 활동해왔다. 본 연구에서는 한반도(북위 $37.5^{\circ}\sim41.5^{\circ}$, 동경 $125.5^{\circ}\sim130.5^{\circ}$)의 월평균 수자원변화량(TWSC: Terrestrial Water Storage Change)을 산정하기 위해 미국 텍사스대학교 공간연구센터(CSR)에서 가우시안 필터링을 통해 구면조화함수의 계수 형태로 제공된 총 94개월(2002 년 8월~2010년 6월)의 자료(Level-2)를 이용하였다. Level-2 자료는 해양조석, 고체지구조석 및 지구자전으로 인한 극조석 등 조석의 영향과 대기와 해양의 변동성으로 인한 비조석 영향을 보정한 것이다. 이렇게 산정한 TWSC를 수자원관리정보시스템(WAMIS)과 전지구지표동계화시스템(GLDAS)을 통해 제공되는 자료와 비교 분석하였다. 본 연구를 통해 GRACE 중력장 자료가 수자원총량의 산정과 검증을 위한 대안으로 활용될 수 있음과, 수문요소의 불확실성을 낮출 수 있는 새로운 수문자료로의 활용 가능성을 확인하였다.

  • PDF

Repair method application for micro-cracks of less than 0.3 mm width in residential apartment buildings (공동주택에 발생되는 0.3mm미만 미세균열의 보수공법 적용을 위한 근거 마련 기초연구)

  • Park, So-Young;Yoo, Jae-Yong;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.105-106
    • /
    • 2018
  • Cracks are typical defects that occur in concrete structures. When cracks occur in the structure, durability reduction, concrete neutralization, and steel corrosion cause functional safety problems. In order to prevent such cracks, surface repair method is performed for cracks smaller than 0.3 mm and rechargeable method is performed for cracks larger than 0.3 mm. However, even if it is applied by the surface repair method at less than 0.3 mm, re-leakage cracks continue to occur. Recently, the Supreme Court ruled that the rechargeable method should be applied to cracks less than 0.3mm in order to reduce the occurrence of defects. However, it was considered that the repair fees were too high relative to the observed defect rate, resulting in a necessitation of modifying the existing construction analysis administration standards. This study analyzes the differences in the subjective views on the durability degradation with regards to surface repair methods in concrete structures.

  • PDF