• Title/Summary/Keyword: 물투과

Search Result 1,146, Processing Time 0.024 seconds

Dimensionality Reduced Wave Transmission Function and Neural Networks for Crack Depth Estimation in Concrete Structures (차원 축소된 표면파 투과 함수와 인공신경망을 이용한 콘크리트 구조물의 균열 깊이 평가 기법)

  • Shin, Sung-Woo;Yun, Chung-Bang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.247-253
    • /
    • 2007
  • Determination of crack depth in filed using the self-calibrating surface wane transmission measurement and the cutting frequency in the transmission function (TRF) is very difficult due to variations of the measurement conditions. In this study, it is proposed to use the measured full TRF as a feature for crack depth assessment. A Principal component analysis (PCA) is employed to generate a basis of the measured TRFs for various crack cases. The measured TRFs are represented by their projections onto the most significant principal components. Then artificial neural networks (NNs) using the PCA-compressed TRFs is applied to assess the crack in concrete. Experimental study is carried out for five different crack cases to investigate the effectiveness of the proposed method. Results reveal that the proposed method can be effectively used for the crack depth assessment of concrete structures.

Synthesis of $H_2$-Permselective Silica Films by Chemical Vapor Deposition (화학증착(CVD)에 의한 선택적 수소 투과성 실리카막의 제조)

  • 남석우;하호용;홍성안
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.21-32
    • /
    • 1992
  • Hydrogen-permselective silica membranes were synthesized within tim walls of porous Vycor tubes by chemical vapor depostion of $SiO_2$. Film deposition was carried out using $SiCl_4$ hydrolysis either in the oppm shag reactants or in the one-sided geometry. At temperatures above $600^{\circ}C$ the permeation rate of hydrogen thorough the silica films varied between 0.01 and $025cm^3(STP)/cm^2-min-atm$ depending on the reaction geometry and the $H_2 : N_2$ permeation ratio was about 1000. Permeation rates of both $H_2$ and $N_2$ increased with increasing temperature. The silica membranes produced by one-sided deposition have higher hydrogen permmeation rates than those produced by the opposing reactants geometry although the membranes formed in an opposing reactants geometry were relatively stable during the heat treatment or after exposure to ambient air. These membranes can be applied to high temperature gas separations or membrane reactors once the film deposition process is optimized to get high permeability as well as good stability.

  • PDF

Separation Characteristics of Aqueous Isopropanol Solution by Pervaporation (투과증발에 의한 이소프로판올 수용액의 분리특성)

  • 이규일;김현진;김진환
    • Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.22-31
    • /
    • 1996
  • Pervaporation experiments of isopropanol-water mixtures through a polydimethytsiloxane(PDMS) membrane were carried out at 35$^{\circ}$C and the effect of isopropanol concentration on the separation characteristics was investigated. The total permeation rate showed the largest deviation from the ideal permeation rate at the isoprpanol volume fraction from 0.5 to 0.7, which resulted from the interaction effect between permeants. The plasticizing effect of isopropanol enhanced the permeation of water, while the existance of water resulted in the depression of isopropanol permeation. Both the permeation rate and the selectivity were predicted using Flory-Huggins thermodynamics and modified Maxwell-Stefan equation. The concentration-dependent diffusion coefficients were expressed by Vignes equation. The Flory-Huggins interaction parameter between isopropanol and water was calculated using excess Gibbs energy correlation and the interaction parameters between liquid and polymer membrane were determined by equilibrium swelling experiments. The predicted permeation rates were in accord with the experimental ones within maximum error range of 35 %. The predicted permeation selectivities were in good agreement with the experimental values.

  • PDF

A Study on Polymeric Membranes for Oxygen-electrode System (산소전극 시스템에 사용되는 고분자막에 관한 연구)

  • 박희영;김현준;정용섭;홍석인
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.52-53
    • /
    • 1995
  • 현재 상용화 되어있는 산소/질소 분리용 고분자 분리막은 비교적 낮은 선택도를 가지고 있다. 즉, 이점은 확산도와 용해도를 조절함으로써 분리막의 투과선택도를 높일 수 있는 가능성을 보여주고 있으며 보다 높은 투과도와 투과선택도를 갖는 새로운 고분자 재료의 선택이 분리막을 통한 기체 분리나 그 상업적 이용에 절실히 요구되고 있다. PSf는 상용성, 화학적 내구력, 강도, 높은 유리전이온도와 우수한 기체투과성질을 가진 고분자로 분리막에 많이 응용되고 있다. Erb 등은 용매로 DMF(dimethylformamide)와 THF(tetrahydrofuran)를 사용하여 막을 제조하였다. 상부 흐름압력이 5atm일때 각 기체의 투과도 계수는, 헬륨이 11, 이산화탄소가 5.5, 메탄이 0.5, 질소가 0.2였으며, PSf막에 대한 각 기체의 투과는 Henry mode보다 Langmuir mode에서 더욱 우세하게 일어난다고 생각하였다. 또한 Ghosal 등은 PSf에 nitro기를 도입한 nitrated PSf의 투과특성을 조사하였다. 실험결과 nitro group이 치환된 PSf막이 nitro group이 없는 막에 비해 투과도는 낮았지만 선택도는 증가하였다. 구조가 다른 여러가지의 PSf막을 통한 기체 투과성질은 Ghem 등에 의해 밝혀졌다. Membrane-covered probes를 이용한 폴라로그램(polarogram) 방법은 산소를 측정하는데 가장 보편적인 방업ㅂ으로, 산소 탐침(oxygen probe)의 원리는 소위 효소 전극을 발전시키는데 이용되어 왔다. 효소전극은 산소와 실험하고자 하는 물질간의 특정한 효소반응에 기초를 둔 다양한 물질의 선택적 측정을 위한 것이다. 이때 센서에 응용되는 합성막은 산소에 대해 선택적인 투과를 해야하며, 상대적으로 높은 산소확산계수와 물에 대해서는 낮은 투과도를 가져야 한다. 높은 산소확산계수는 반응을 빠르게 하는 잇점이 있으며 물에 대한 낮은 투과도는 센서내의 전해질 물질을 유지보호하는 역할을 한다. 분리막이 산소전극에 이용될 경우 높은 산소 확산계수 이외에도 적절한 기계적 강도, 열적 안정성 등이 요구된다.

  • PDF

The Preparation of a Polyimide Membrane for the Separation of Water-Acetic Acid Mixture through Pervaporation (Polyimide 막에 의한 물-초산계의 투과증발 분리)

  • 박영태
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.215-220
    • /
    • 1999
  • The asymmetric polyimide [PI] membrane with good solvent-resisting and heat-resisting properties was prepared by using the phase inversion method from polyamic acid, and its pervaporation separation characteristics of water-acetic acid system were studied. It was appeared from the prepared membranes that the best non-solvent of polyamie acid for the phase inversion was toluene. The best heat-treatment condition for the imidization of polyamic acid was 1 hr heating at each of the temperatures, 373, 473, and 573 K The thermal durability and chemical stability during the pervaporation separation of water-acetic acid of the prepared PI membrane was superior. The pervaporation characteristics of prepared membrane were 180 of separation factor and 0.5 kg/$m^2$hr of total flux for 80 wt% acetic acid feed.

  • PDF

Separation of Alcohol/water Mixtures with Surface-modified Alumina Membrane in Vapor Permeation (표면개질 알루미나막의 증기투과에 의한 알코올의 분리)

  • 이상인;오한기;이광래
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.121-129
    • /
    • 2000
  • The membrane requires both high in selectivity and flux. However, the permselective membrane has low flux. In this study, the porous alumina membrane was coated with silane coupling agent in order to enhance the flux with proper selectivity. The contact angle of water to the surface-modified alumina membrane was greater than 90$^{\circ}$, which indicated the high hydrophobicity. The modified membrane was tested in vapor permeation for the concentration of aqueous ethanol, isopropanol, and n-butanol. With the increase of ethanol, isopropanol, butanol concentration in the feed, permeation flux increased due to the greater affinity of ethanol, isopropanol, butanol with surface-modified alumina membrane than that of water. The experimental results showed that the permeation tate of surface-modified alumina membrane was 20~1000 times greater than that of a polymer membranes.

  • PDF

Poly(dimethylsiloxane)/Ceramic 복합막을 이용한 투과증발에서의 선택도에 대한 온도의 영향

  • 홍연기;홍원희
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.124-126
    • /
    • 1997
  • 1. 서론 : 투과증발이란 비다공성 고분자막을 이용하여 수착, 확산, 및 증발기구를 통해 액체혼합물을 분리하는 기술이다. 따라서 투과증발의 분리효율은 고분자막의 종류 및 형태의 다양성뿐만 아니라 여러 단계의 기구 특성에 의해 결정된다. 일반저긍로 투과증발막의 성능은 분리하고자 하는 물질에 대한 선택도와 투과도로서 나타날 수 있다. (중략) 본 연구에서는 Poly(dimethylsiloxane)과 세라믹 지지체의 복합막을 이용하여 IPA(Isopropanol)/물 계에서의 여러 조업변수에 따른 IPA의 분리특성을 연구하였다.

  • PDF

Pervaporation Separation of Ethanol-Water Mixtures Using Nylon 4 and Its Blended Membranes (나일론 4와 이의 블렌드 막을 이용한 에탄올-물 혼합물의 투과 증발분리)

  • Rhim, Ji-Won;Huang, Robert Y.M.
    • Applied Chemistry for Engineering
    • /
    • v.4 no.4
    • /
    • pp.791-797
    • /
    • 1993
  • The application of the pervaporation process in biotechnology is rapidly growing. A two stage pervaporation process can be applied to the downstream processing of ethanol fermentation. In this paper, the second stage process in which the water-ethanol composition was 50:50 wt.% was investigated in more detail by using Nylon 4 and its blended membranes containing poly(vinyl alcohol) (PVA) and poly(acrylic acid) (PAA). Nylon 4 membranes were tested for compositions at 25, 30, and $35^{\circ}C$. Nylon 4 membranes had a separation factor of 4.18 with a permeability of $0.69kg/m^2hr$ at water-ethanol composition of 50:50 wt.%, while nylon 4-PVA blended membranes crosslinked by 5 Mrad gamma-ray irradiation showed a higher separation factor of 10.56 with permeability $0.55kg/m^2hr$ at the same composition. Nylon 4 also showed a high separation factor 27.8 at the ethanol-water azeotropic composition among the homopolymer membranes.

  • PDF

The Statistical Hypothesis Verification to Influence of Addition of Metakaolin and Silica Fume on Compressive Strength and Chloride Ion Penetration of High Strength Concrete (메타카올린 및 실리카퓸의 혼입이 고강도 콘크리트의 압축강도와 염소이온 투과에 미치는 영향에 관한 통계적 가설검증)

  • Min, Jeong Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.215-225
    • /
    • 2011
  • Metakaolin is a dehydroxylated form of the clay mineral kaolinite. Rocks that are rich in kaolinite are known as china clay or kaolin, traditionally used in the manufacture of porcelain. The particle size of metakaolin is smaller than cement particles, but not as fine as silica fume. This paper investigates the effect of the concrete containing metakaolin as a mineral admixture on the compressive strength and resistance properties to chloride ion penetration. In this study, the experiment was carried out to investigate and analyze the influence of replacement ratio of metakaolin and micro silica fume on the compressive strength and chlorine ion penetration resistance of concrete. All levels were water/binder ratio 30%, replacement ratio of metakaolin and silica fume were 0, 5, 10, 15, 20% respectively. The compressive strength of concrete using metakaolin tends to increase, as the replacement ratio increases but the chlorine ion penetration resistance was not so as lager as silica fume concrete. Therefore, the optimum mixing ratio of metakaoline to satisfy a properties of compressive strength and chlorine ion penetration resistance was was approximately10%.

Pervaporation Separation of Water-iso-Propyl Mixture Using PVA/PAA Membranes (PVA/PAA막을 이용한 물-이소프로필알코올 혼합물의 투과증발 분리)

  • Rhim, Ji-Won;Kim, Sun-Woo;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.6 no.4
    • /
    • pp.284-288
    • /
    • 1996
  • The crosslinked PVA/PAA membranes developed in our laboratory have been characterized for water-isopropyl alcohol mixture in terms of permeabilities and separation factor. When the feed mixture was 12wt% water, the permeability and the separation factor for PVA/PAA=75/25 membrane show $63g/m^{2}h$ and 1520 at $80^{\circ}C$, respectively. In case of 5wt% water in feed mixture, the permeability for PVA/PAA=75/25 membrane is $56g/m^{2}h$ at 8$0^{\circ}C$ while the separation factor is 1563.

  • PDF