Abstract
The asymmetric polyimide [PI] membrane with good solvent-resisting and heat-resisting properties was prepared by using the phase inversion method from polyamic acid, and its pervaporation separation characteristics of water-acetic acid system were studied. It was appeared from the prepared membranes that the best non-solvent of polyamie acid for the phase inversion was toluene. The best heat-treatment condition for the imidization of polyamic acid was 1 hr heating at each of the temperatures, 373, 473, and 573 K The thermal durability and chemical stability during the pervaporation separation of water-acetic acid of the prepared PI membrane was superior. The pervaporation characteristics of prepared membrane were 180 of separation factor and 0.5 kg/$m^2$hr of total flux for 80 wt% acetic acid feed.
고농도의 초산수용액(80 wt% 이상)을 분리 농축하기 위하여 내용매성이 우수하며 고온에서의 내열성을 가지는 폴리이미드 비대칭막을 만들어 막의 특성을 검토하고 물-초산 계의 투과증발 분리성능을 고찰하였다. 제막은 폴리아믹산의 상전이용액으로 톨루엔을 사용한 것이 가장 좋은 상태의 막을 얻을수 있었다. 열처리에 의한 imide화는 373, 473573 K에서 각각 1시간씩 연속적으로 처리하는 것이 가장 효과적이었다 막은 물-초산 계의 투과증발 분리에 의한 열내구성 및 화학적 안정성이 우수하였다 폴리이미드막의 투과증발 분리특성은 80 wt% 초산수용액 계에서 분리계수는 180 투과유속은 0.5kg/$m^2$hr을 얻을 수 있었다.