• Title/Summary/Keyword: 물리 흡수

Search Result 590, Processing Time 0.029 seconds

CO2 Capture Performance of Dry Sorbents Manufactured by Coal Fly Ash (석탄 화력발전소의 비산재를 이용한 건식 CO2 흡수제 제조 및 특성 연구)

  • Lee, Jae Hee;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.8
    • /
    • pp.547-553
    • /
    • 2013
  • This paper investigates the effect of coal-fired fly ash on dry $CO_2$ sorbents as the supports and additives. For this purpose, various kinds of dry sorbent were manufactured by mixing fly-ash, the primary $CO_2$ absorption components (NaOH and CaO) and water with their different combination. Thereafter, their $CO_2$ absorption performance and the property were analyzed. As a result, variation of absorption efficiency and temperature as well as $CO_2$ desorption of the sorbents are confirmed, which may be primarily ascribed to fly-ash addition to the sorbents. Particularly, fly-ash effect is strongly measured in the sorbent manufactured by mixing all four components (named WNCF sorbents). Absorption efficiency of WNCF sorbents at $550^{\circ}C$ is 35.6% higher than that of flyash free sorbent and desorption is solely observed in WNCF sorbents. Fly-ash in WNCF sorbents leads to increase the dispersity of $CO_2$ absorption components and decrease their particle size in the sorbents. In addition, fly-ash is used as the supports and pozzolanic reaction is hindered by NaOH in WNCF sorbent. Furthermore, $CO_2$ desorption from the sorbents may be due to fly-ash. The interaction between fly-ash and $CO_2$ absorption components substantially attenuate the strength between captured $CO_2$ in CaO and NaOH.

Optical Diagnosis and Imaging for Medicine (빛을 이용한 의료용 진단과 이미징)

  • 김법민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.2-3
    • /
    • 2003
  • 빛이 생체조직에 조사되면 흡수, 산란과 같은 물리적 반응과 형광, 라만 등과 같은 화학적 반응을 일으키게 된다. 이러한 현상들은 생체조직내의 구성방식에 따라 또는 정상적, 병적 변화에 따라 각기 다르게 나타나며 이들을 이용하여 암 등 병적인 조직변화에 대한 진단이나 조직 내부의 이미징을 수행할 수 있다. (중략)

  • PDF

Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses (다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포)

  • Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1999
  • Purpose: TLD experiments were set up to measure the dose distribution and to analyze the influence on dose measurement of thin metal plate and solid water phantom. The aim of the present study was to investigate the build-up effect of metal plate loaded on TLD chip and depth dose in the controlled environment of phantom measurements. Materials and Methods: Measurements were done by using LiF TLD-100 loaded by a thin metal plate with the same surface area (3.2$\times$3.2 $\textrm{mm}^2$) as TLD chip. TLD chips loaded with one metal plate from three different metal plate (Tin, Copper, Gold) of different thicknesses (0.1, 0.15, 0.2, 0.3 mm) were used respectively to measure radiation dose. Using the TLD loaded with one metal plate, surface dose and the depth dose at the build-up maximum region were investigated. Results: Using a metal plate on TLD chip increased the surface dose. Surface dose curve shows the dose build-up against equivalent thickness of metal to water. The values of TL reading obtained by using metal plate at depth of build-up maximum are about 8% to 13% lower than those obtained by normal TLD chip. Conclusion: The metal technique used for TLD dosimetry could provide clinicals information about the build-up of dose up to 4.2mm depth in addition to a depth dose distribution. The results of TLD with a metal plate measurements may help with decisions to boost or bolus certain areas of the skin.

  • PDF

Photoacoustic Nonlinearity to Absorption Coefficients in Photoacoustic Imaging with Focused Ultrasound Transducers (초점 초음파 측정기로 측정한 광음향 신호의 광 흡수계수에 대한 비선형성)

  • Kang, Dongyel
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.158-165
    • /
    • 2017
  • The physical shape of an ultrasound transducer has not been considered in previous studies of the photoacoustic saturation effect, where a photoacoustic signal's magnitude linearly increases as an absorption coefficient increases and it is finally saturated. In this paper, the effect of a spherically focused ultrasound transducer on photoacoustic nonlinearity is investigated. The focused ultrasound transducer's spatial filtering effect on photoacoustic signals is analytically derived considering the combined concept of a virtual point detector and Green function approach. The ultrasound transducer's temporal response (i.e., transfer function) effect on photoacoustic signals is considered by integrating photoacoustic signal values within the absorption area covered by a spatial resolution of the ultrasound transducer. Results from the analytically derived expression show that the magnitude of photoacoustic signals measured by a spherical focused ultrasound transducer shows a maximum at a specific absorption coefficient, and decreases after that maximum point as an absorption coefficient is increased. The origin of this photoacoustic nonlinearity is physically understood by comparing the ultrasound transducer's transfer functions and photoacoustic resonance spectra. In addition, this physical interpretation implies that the photoacoustic nonlinearity is strongly dependent on the irradiance distribution inside an absorption medium.

The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy (전립선암의 세기조절 방사선 치료시 밀도보정의 효과)

  • Han Youngyih;Park Won;Huh Seung Jae
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.149-155
    • /
    • 2004
  • Purpose: To investigate the effects of tissue inhomogeneity corrections on the dose delivered to prostate cancer patients treated with Intensity-Modulated Radiation Therapy (IMRT). Methods and Materials: For five prostate cancer patients, IMRT treatment plans were generated using 6 MV or 10 MV X-rays. In each plan, seven equally spaced ports of photon beams were directed to the isocenter, neglecting the tissue heterogeneity in the body. The dose at the isocenter, mean dose, maximum dose, minimum dose and volume that received more than 95% of the isocenter dose in the planning target volume ( $V_{p>95%}$) were measured. The maximum doses to the rectum and the bladder, and the volumes that received more than 50, 75 and 90% of the prescribed dose were measured. Treatment plans were then recomputed using tissue inhomogeneity correction maintaining the intensity profiles and monitor units of each port. The prescription point dose and other dosimetric parameters were remeasured. Results: The inhomogeneity correction reduced the prescription point dose by an average 4.9 and 4.0% with 6 and 10 MV X-rays, respectively. The average reductions of the $V_{p>95%}$ were 0.8 and 0.9% with the 6 and 10 MV X-rays, respectively. The mean doses in the PTV were reduced by an average of 4.2 and 3.4% with the 6 and 10 MV X-rays, respectively. The irradiated volume parameters in the rectum and bladder were less decreased; less than 2.1 % (1.2%) of the reduction in the rectum (bladder). The average reductions in the mean dose were 1.0 and 0.5% in the rectum and bladder, respectively. Conclusions: Neglect of tissue inhomogeneity in the IMRT treatment of prostate cancer gives rise to a notable overestimation of the dose delivered to the target, whereas the impact of tissue inhomogeneity correction to the surrounding critical organs is less significant.

  • PDF

Evaluation of Physical Properties and Biocompatibility of HA-Dex Fusion Hydrogel Patch for Atopic Healing Ability (HA-Dex 융복합 하이드로겔 패치의 아토피 치유 능력에 대한 물리적 특성 및 생체 적합성 평가)

  • Hong, Gyeong Sik;Choi, Jeong Yeon;Choi, Jin Hyun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2020
  • Recently, since atopic dermatitis is sensitive to skin irritation, it has been suggested that the development of a patch that can effectively exhibit adhesion and absorption to a specific local area while minimizing skin irritation, and capable of appropriate drug release should be given priority. In this study, we tried to develop a hydrogel patch that minimizes skin irritation, adheres effectively to a specific area, and promotes absorption. The atopic patch was formulated into a super-absorbent hydrogel sheet using a freeze drying method. Cell viability assay was carried out using keratinocytes (HaCaT cell) and fibroblasts (L929 cells). In order to investigate the physical properties, FT-IR, FE-SEM, porosity analysis and swelling behavior were investigated. As a result, the newly prepared HA-Dex hydrogel patch was verified by biocompatibility and physical evaluation. In addition, the manufactured hydrogel patch has sufficient moisture absorption capacity and can relieve itching of atopic skin, and is expected to be applied to various drug delivery products for the treatment of atopic dermatitis in the future.

Monte Carlo Simulation for Dose Distributions from Ir-192 in Brachytherapy (근접 방사선치료용 이리듐 선원의 선량분포에 대한 몬데칼로 시뮬레이션)

  • 김승곤;강정구;이정옥;정동혁;문성록
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.187-194
    • /
    • 2002
  • In this work we investigated through Monte Carlo calculations the physical characteristics of the absorbed dose from the Ir-192 source used in brachytherapy The Monte Carlo calculations were performed using the code EGS4, which was extensively modified in order to handle cylindrical sources, phantoms, and energy distributions to suit out own purpose. From the results of the calculations for the $\beta$ -rays, it was found that they contribute on the average 0.02% to The total absorbed dose in the distance range of 0.5-5.0 cm from the source. This is due to the face that, although most of the primary $\beta$ -rays are absorbed in the source and encapsulation material, the resulting low energy braking radiation from them contribute to such a distance. The absorbed dose in the encapsulation material varied on the average from 2.8% for platinum down to 1.1% for iron. The radial dose functions obtained by our Monte Carlo calculations were consistent within $\pm$3% with those of the TG-43 report for the radial distance interval 0.5-10.0 cm from the source. The user code we wrote in this work can be used for other sources of different sizes and so it can be very useful in designing and producing the sources for brachytherapy.

  • PDF

Characteristics of Track-Etch PN-3 Dosimeters for Alpha Particles (알파입자 부식-새김을 이용한 PN-3 선량측정기의 특성)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.97-107
    • /
    • 1990
  • A method of detecting charged particles in an allyl diglycol carbonate material (PN-3) which is available, amorphous, optically clear and thermoset plastic in which nuclear particle tracks could be revealed by etching in hot NaOH solutions, has been investigated. It has been applied to the study of alpha particle tracks over an energy range of 3.17~5.49 MeV which has been obtained after having passed through several sheets of polycarbonate. The dose equivalent rate of the alpha source was calculated and the spark chamber was used in order to measure the range of alpha particles after having passed through different number of absorbers. The etching characteristics and the detection response of PN-3 have been studied as a funcion of lengths of etched tracks against the parameters of energies and of the track etching rate(V$_{T}$). The investigation of the etching process for alpha particles in the PN-3 provided the most interesting results.s.