• Title/Summary/Keyword: 물리 흡수

Search Result 590, Processing Time 0.035 seconds

Measurement of Energy Parameters for Electron Gun Heater Currents and Output Dose Rate for Electron Beams from a Prototype Linac (연구용 선형가속기의 전자총 가열 전류에 따른 전자선의 에너지 인자 측정과 출력 측정 연구)

  • Lim, Heuijin;Lee, Manwoo;Kim, Me Young;Yi, Jungyu;Lee, Mujin;Kang, Sang Ku;Rhee, Dong Joo;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.25-30
    • /
    • 2016
  • The dosimetric characteristics were experimentally evaluated for electron beams from the prototype linac developed for radiotherapy units. This paper focuses on the electron beam output and energy variations as a function of electron gun heater current. The electron energy was derived from its mean and most probable energies measured by film dosimetry. The electron beam output at the maximum electron energy was measured with the plane parallel ionization chamber in water using TRS-398 dosimetry protocol. The mean energy and the most probable energy of the electron beam were 6.54~3.31 MeV and 5.94~2.80 MeV at electron gun current of 2.02~2.50 A respectively. The output dose rate for an electron beam of mean energy 6.54 MeV was 5.41 Gy/min ${\pm}1.5%$ at the reference depth in water.

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Absorbed Dose Determination for a Biological Sample Irradiated by Gamma Rays from a Cs-137 Source (Cs-137 감마선에 대한 생물학 연구용 시료의 흡수선량 결정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jeung-Kee;Yang, Kwang-Mo;Ju, Min-Su;Kim, Min-Young;Lee, Chang-Yeol;Kim, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.124-130
    • /
    • 2011
  • In this study the dosimetric evaluation for a biological sample irradiated by gamma rays from Cs-137 irradiator (Gamma Irradiator, Chiyoda Technol Co., Japan) was performed for radiobiological experiment. A spherical water with a diameter of 3 cm was assumed as a biological sample. The absorbed dose were determined by the air kerma based dosimetric calculation system. The theoretical and Monte Carlo calculations (MCNPX) were performed and compared to evaluate measured air kerma and determined absorbed dose respectively. As a result of comparison with theoretical calculation, the measured air kerma was in good agreement within 3.1% at the distance of 100 and 200 cm from the source. In comparison with Monte Carlo results the determined absorbed dose along the central axis was in good agreement within 1.9% and 3.7% at 100 cm and 200 cm respectively. Although the preliminary results were obtained in this study these results were used as a basis of dosimetric evaluation for radiobiological experiment. Extended study will be performed to evaluate the dose in various conditions of biological samples.

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF

The Measurement of Ho-166 Absorbed Dose for the Endovascular Irradiation with a Balloon Angio Catheter Using a GafChromic Film (GafChromic 필름을 이용한 Ho-166 의 혈관내 방사선조사를 위한 선량분포 측정)

  • 강해진;조철우;박찬희;오영택;전미선;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The GafChromic film was used for the dosimetry of a balloon angio catheter filled with the radioisotope HO-166 for endovascular irradiation. The balloon angio catheter was 2 cm long and 3 mm in diameter when inflated. The isotope, Ho-166, was produced by the neutron bombardment using the research reactor in Korea Atomic Energy Research Insititute. Co-60 teletherapy beam was used for making H-D curve for the Gaf-Chromic film. The film dosimetry was measured with a videodensitometer. The radial dose distribution indicated that the absorbed dose dropped to about 20% of the surface dose at the 1 mm away from the balloon surface and at 5 mm position the dose decreased to below 1% of the surface dose. The result also shows that with the specific activity of Ho-l66, 250 mCi/ml it takes 230 seconds to deliver 1200 cGy to the region where is 1mm away from the balloon surface. The concentric isodose curves were also presented. The Ho-166 is an another alternative for endovascualr irradiation to prevent restenosis after PTCA (Percutaneous Trans Coronary Angioplasty)

  • PDF

Synthesis of Aminated Poly(ether sulfone) as Anion Exchanger and its NO Gas Adsorption (Aminated Poly(ether sulfone)의 합성과 NO 가스의 흡착특성)

  • Son, W.K.;Park, S.G.
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.857-862
    • /
    • 1999
  • Aminated poly(ether sulfone)(APES) was prepared by amination of nitrated poly(ether sulfone)(NPES) after poly(ether sulfone)(PES) was nitrated with mixed acid of nitric acid and sulfuric acid(sulfuric acid is a catalyst). As a results of the FT-IR spectrum analysis, the nitration of PES was confirmed by the bands of asymmetric stretching and symmetric stretching of $NO_2$ group at 1537 and $1351cm^{-1}$, respectively. Also when the NPES was aminated, it was disappeared to absorbance peaks of $NO_2$ group. And It was confirmed by the bands of asymmetric stretching and symmetric stretching of $NH_2$ group at 3470 and $3374cm^{-1}$, respectively. The optimum condition of the nitration on PES(5 g; 21.55 mmol.) was 12 hr of reaction time, $120^{\circ}C$ of reaction temperature, nitric acid of 28.00 mmol. and sulfuric acid of 52.00 mmol. As a result of the elemental analysis of APES, reapeating unit per amine groups were induced to 0.89. The adsorption rate of NO gas was lower than that of silica gel and active carbon. But the adsorption capacity of NO gas was higher than that of these. When the APES was absorbed to NO gas, the chemical adsorption rate was lower than the physical adsorption rate. But the chemical adsorption capacity of it was higher than physical adsorption capacity.

  • PDF

란타넘족 이온을 이용한 가시광선 대역에서의 산화그래핀 광환원

  • O, Ae-Ri;Yu, Gwang-Wi;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.202.1-202.1
    • /
    • 2015
  • 탄소의 $sp^2$ 혼성으로 이루어진 2차원 단일시트(two-dimensional single sheet)인 그래핀은 기계적, 열역학적, 전기적 특성이 매우 우수하며 특히 고유연성과 투명성을 가진다는 장점 때문에 오랜 기간 주목 받으며 다양한 분야에서 연구되어 왔다. 이러한 그래핀을 만드는 방법에는 화학적 증기 증착법 및 흑연으로부터의 물리적, 화학적 박리 방법이 있다. 양질의 그래핀을 대면적에서 획득 할 수 있는 화학적 증기 증착법의 경우 높은 공정 비용과 함께 수반되어야 하는 전사과정의 어려움으로 인하여 실제 상용화에 어려움이 있다. 이러한 단점의 극복을 위해 대량의 그래핀을 저렴하게 확보 할 수 있는 화학적 박리 방법이 주목을 받고 있다. 화학적 박리 방법의 경우 박리 과정에서 수반되는 산화 그래핀의 환원과정이 필요하였으며, 이를 위해 강력한 환원제를 이용한 화학적 환원 방법, 고온에서의 열처리를 이용한 열역학적 환원 방법, 및 빛을 노광시켜 산화 그래핀을 환원시키는 광학적 방법이 시도되었다. 화학적 및 열역학적 환원방법의 경우 고품질의 환원된 산화 그래핀을 획득 할 수 있으나, 강한 환원제 및 높은 열처리 온도로 인하여 유연 기판의 사용이 제한되는 단점이 있다. 이러한 단점을 극복하기 위해 빛을 이용한 광학적 방법이 제시되었으나, 환원과정에 사용되는 단파장의 자외선 광원의 높은 가격으로 인하여 경제성의 확보가 제한된다. 본 논문에서는 우수한 광학적 특성을 보이는 란타넘족 이온을 사용하여 선택적 파장 대에서 높은 광흡수도를 가지는 산화 그래핀-란타넘 이온 혼합용액을 만들었으며, 가시광선대역의 파장을 가지는 레이저를 사용하여 우수한 품질을 가지는 환원된 산화 그래핀을 제작하였다. 구체적으로 산화 그래핀은 modified hummer's method를 이용하여 만들어졌으며, 자외선 대역을 흡수하는 $Gd_{3+}$, 녹색 레이저를 흡수하는 $Tb_{3+}$, 적색 레이저를 흡수하는 $Eu^{3+}$를 1 mM 섞어주었다. 그 후, 300~800 nm의 파장을 가지는 레이저를 $1mW/cm^2$를 노광시켜 산화 그래핀을 환원시켰다. 환원된 산화 그래핀의 특성은 FT-IR, UV-Vis, 저온 PL, SEM, XPS 및 전기측정을 이용해 측정하여 재현성 및 반복성을 확인하였다.

  • PDF

Design of Single Layer Radar Absorbing Structures(RAS) for Minimizing Radar Cross Section(RCS) Using Impedance Matching (임피던스정합을 이용한 레이더반사면적 최소화 단층형 전파흡수구조 설계)

  • Jang, Byung-Wook;Park, Jung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.118-124
    • /
    • 2015
  • The design of radar absorbing structures(RAS) is a discrete optimization problem and is usually processed by stochastic optimization methods. The calculation of radar cross section(RCS) should be decreased to improve the efficiency of designing RAS. In this paper, an efficient method using impedance matching is studied to design RAS for minimizing RCS. Input impedance of the minimal RCS for the specified wave incident conditions is obtained by interlocking physical optics(PO) and optimizations. Complex permittivity and thickness of RAS are designed to satisfy the calculated input impedance by a discrete optimization. The results reveal that the studied method attains the same results as stochastic optimization which have to conduct numerous RCS analysis. The efficiency of designing RAS can be enhanced by reducing the calculation of RCS.

Studies on the Near Infrared Diffuse Reflection Spectroscopy for Meat Components (근적외선 반사분광분석법에 의한 정육 및 그 구성성분의 반사 spectra에 관한 연구)

  • Oh, Eun-Kyong;Grossklaus, Dieter
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.404-407
    • /
    • 1992
  • This study was conducted to determine the effect of the physical and chemical factors on the absorbance when the chemical component of food was rapidly and effectively analyzed with near infrared reflection spectrophotometer. The absorbance was measured within the wavelength range of 1100 and 2500m and at the various sample temperatures. The absorbance was greatly increased with the rising sample temperature. When the grinding time of samples prolonged, the absorbance was decreased. The absorption peaks occurring in the near infrared spectra of meat, meat protein, pork fat and water were attributed to the overtone and combination vibration of C-H, N-H, O-H or C=O bond within the macromolecules of each sample. The absorbance was lower for meat protein than other meat components. Pork fat was characterized by the ${\cdot}CH_2{\cdot}$ absorption peak at the wavelength of 1700 and 2300 nm and water by the relatively high absorption peak at the wavelength of 1450 and 1930 nm. As a result, the absorbance of near infrared reflection spectrum of meat was affected mainly by fat and water in meat.

  • PDF

A Study on the Photo-Degradation Properties of the Spiropyran Using THz-TDS (테라헤르츠 시간 영역 분광법을 이용한 스피로파이란의 광 퇴화 특성 연구)

  • Bang, Jin-Hyuk;Park, Myoung-Hwan;Ryu, Han-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • The spiropyran is a typical material having photodegradation properties in the process of photochromism. The spiropyran has been utilized in various applications such as optical switch, optical memories, and biosensor because of its remarkable stability, fast responsive time, stronger color change, and photo-induced controllability. However, the spriropyran is photodegraded by the repetitive optical irradiation. The photodegradation of spiropyran have been investigated by using UV-Visible spectroscopy, nuclear magnetic resonance (NMR), and Raman spectroscopy. Herein, the properties of spiropyran were characterized by using terahertz time-domain spectroscopy (THz-TDS) in the terahertz frequency region. In terahertz region, the measured absorbance of spiropyran was increased due to the photodegradation induced by the repetitive UV irradiation. The absorbance tendency of spiropyran in the terahertz frequency region was compared with that in the visible region, and they were completely opposite to each other.