• Title/Summary/Keyword: 물공급시스템

Search Result 554, Processing Time 0.03 seconds

Electrokinetic-Fenton Process for Removal of Phenanthrene (동전기-펜턴 공정을 이용한 phenanthrene 오염토양의 정화)

  • 양지원;박지연;김상준;이유진;기대정
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2004
  • Feasibility of electrokinetic process combined with Fenton-like reaction was investigated for the removal of phenanthrene from contaminated soil. Transport of hydrogen peroxide by electroosmosis and decomposition of phenanthrene by Fenton-like reaction were observed in a model system. Electrical potential gradient and electroosmotic flow (EOF) at 10 mA were higher than those at 5 mA. High accumulated EOF resulted in high removal efficiency of phenanthrene because the large amount of hydrogen peroxide was transfered through the soil. Removal efficiency of phenanthrene by water washing was 8.5% for 7 days. The highest removal efficiency including phenanthrene decomposition was 95.6% for 14 days. After the operation, soil samples with removal efficiency of 95.6% showed low concentrations of phenanthrene and its intermediates. From this result, it was presumed that phenanthrene was decomposed to small molecules or mineralized to water and carbon dioxide due to continuous supply of hydrogen peroxide by electroosmotic flow.

A Study on A Dynamic Reliability Analysis Model (동적신뢰도 평가모델의 연구)

  • 제무성
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.239-246
    • /
    • 2000
  • This paper presents a new dynamic approach for assessing feasibility associated with the implementation of accident management strategies by the operators. This approach includes the combined use of both the concept of reliability physics and a dynamic event tree generation scheme. The reliability physics is based on the concept of a comparison between two competing variables, i.e., the requirement and the achievement parameter, while the dynamic event tree generation scheme on the continuous generation of the possible event sequences at every branch point up to the desired solution. This approach is applied to a cavity flooding strategy in a reference plant, which is to supply water into the reactor cavity using emergency fire systems in the station blackout sequence. The MAAP code and Latin Hypercube sampling technique are used to determine the uncertainty of the requirement parameter. It has been demonstrated that this combined methodology may contribute to assessing the success likelihood of the operator actions required during accidents and therefore to developing the accident management procedures.

  • PDF

아크로 증착된 TiAlN 박막의 특성 연구

  • Jeong, Jae-Hun;Yang, Ji-Hun;Park, Hye-Seon;Song, Min-A;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.269-269
    • /
    • 2011
  • 티타늄-알루미늄(Titanium-Aluminum) 질화물(Nitride)은 고경도 난삭재의 고능률 절삭 분야에 사용되는 공구의 수명 향상을 위한 표면처리 소재로 각광을 받고 있다. 건식고속가공을 효과적으로 수행하기 위해서는 코팅막 재료가 가공 중 발생하는 고온에서도 견디는 우수한 내산화성을 지니면서 내마모, 내충격 특성등의 기계적 성질이 우수한 코팅을 필요로 하며 이러한 분야에 TiAlN을 적용하기 위한 많은 연구가 진행되고 있다. 본 연구에서는 아크(Cathodic Arc) 코팅을 시스템을 이용하여 N2 유량변화에 따라 TiAlN 박막을 제조하고 그 특성을 평가하였다. 아크 소스에 장착된 타겟은 120 $mm{\Phi}$, Ti : Al=50 : 50 at% 의 TiAl 타겟을 사용 하였고, 시편과 타겟 간의 거리는 약 30 cm이며, 시편은 SUS를 사용하였다. 시편을 진공용기에 장착하고 ~10-6 Torr까지 진공배기를 실시하고, Ar 가스를 진공용기 내로 공급하여 ~10-4 Torr에서 시편에 bias (Pulse : 400V)를 인가한 후 아크를 발생시켜 약 5분간 청정을 실시하였다. 플라즈마 청정이 끝나면 시편에 인가된 bias를 차단하고 N2 유량을 변화시키며 코팅을 실시하였다. 질소 유량이 증가함에 따라 색상은 회색에서 어두운 보라색으로 변화하였고 SEM 사진을 통해 Micro paticle 이 감소하는 것을 확인 할 수 있었으며 이는 질소유량이 증가 할수록 표면조도 또한 감소하는 분석결과와도 일치하였다. XRD 분석을 통해 질소 유량이 160 sccm 이상에서 TiAlN이 합성되는 것을 볼 수 있었고 질소 유량이 240 sccm일 때 가장 높은 경도를 보였다. 따라서 본 연구에서 얻어진 결과를 바탕으로 더욱 다양한 조건에서 TiAlN 코팅에 응용한다면 다양한 색상 구현과 내마모성 등에서 많은 장점을 얻을 수 있을 것으로 예상된다.

  • PDF

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

Comparative studies for the performance of a natural gas steam reforming in a membrane reactor (분리막 반응기를 이용한 천연가스 개질반응의 성능에 관한 비교 분석)

  • Lee, Boreum;Lim, Hankwon
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • For a natural gas steam reforming, comparative studies of the performance in a conventional packed-bed reactor and a membrane reactor, a new conceptual reactor consisting of a reactor with series of hydrogen separation membranes, have been performed. Based on experimental kinetics reported by Xu and Froment, a process simulation model was developed with Aspen $HYSYS^{(R)}$, a commercial process simulator, and effects of various operating conditions like temperature, $H_2$ permeance, and Ar sweep gas flow rate on the performance in a membrane reactor were investigated in terms of reactant conversion and $H_2$ yield enhancement showing improved $H_2$ yield and methane conversion in a membrane reactor. In addition, a preliminary cost estimation focusing on natural gas consumption to supply heat required for the system was carried out and feasibility of possible cost savings in a membrane reactor was assessed with a cost saving of 10.94% in a membrane reactor.

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF

The Effects of Scope Management on Process Performance and Output Performance in the Information System Development Project : An Analysis from Project Supplier's Perspective (공급자 관점에서 정보시스템 개발 프로젝트의 범위관리활동이 프로세스성과와 결과물성과에 미치는 영향에 대한 연구)

  • Park, Bong-Gu;Lim, Gyoo-Gun;Yoo, Weon-Sang
    • Journal of Information Technology Services
    • /
    • v.8 no.3
    • /
    • pp.83-100
    • /
    • 2009
  • Even though the success of the information system (IS) protect becomes a critical issue to an enterprise and there has been a lot of research about finding critical success factors of IS projects, the scope management for the success of IS protect has received little attention in the literature. The purpose of this research is to investigate the effects of the project scope management activities defined by PMI (Project Management Institute) on the performance of the information system project. The focus of this paper is on the project supplier's point of view. This study shows the priority of the scope management activities during the IS Project. The results show the different results depending on the types of the project clients and the project scale. This research reveals that the scope verification is important for the project supplier from the project process view, and that the scope planning/definition is important for the protect client from the project result view. It also shows different results comparing to the conventional recognition about project success. The research results show that the positive relationships between the project scale and the importance of scope management activities, and between the familiarity of suppliers and clients and the importance of the scope management activities. Through this research, we expect that the importance of the scope management in a project will be considered as an important issue, and that this research will lead to various detailed research about this issue.

The Proposal of Performance Evaluation Techniques for Demo Plant System of SWG (SWG Demo Plant 시스템에 대한 성능평가 기법 제시)

  • Chae, Soo Kwon;Choo, Tai Ho;Yoon, Hyeon Cheol;Yun, Gwan Seon;Kwon, Yong Been
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.215-215
    • /
    • 2015
  • SWG(Smart Water Grid)는 한정적인 수자원을 효율적으로 이용하고 사용자 입맛에 맞춰 물을 안정적으로 공급하고자 하는 양방향 개념으로 수자원 분야에서 각광받는 실정이다. SWG의 성능을 평가하는 연구사례는 많지 않으며 현재 국내의 경우 실증단지를 구축하고 있는 단계이다. 그러므로 성능평가를 수행하기 위한 실측자료가 부재하므로 성능평가 지표선정에 활용 할 수 있는 자료가 제한적이다. 따라서 미국의 Leed, 영국의 BREEAM, 일본의 CASBEE, 호주의 Green Star의 인증 기준에서 수자원에 대한 항목과 기존의 IWA, World Bank, AWWA, JWWA, OFWAT 같은 해외 상수도 수행능 지표와 상수도 및 정수장 기술진단에서 제시하는 기준을 바탕으로 성능평가지표를 선정 보완하여 Water Facility Index, Smart Index, Optimum System Index로 분류하여 각 세부의 성능평가지표를 선정하였다. 선정된 지표는 AHP기법를 활용하여 1-4단계에 걸쳐 계층화를 실시하고 Bottom-up방식으로 4단계에서부터 1단계로 평가를 진행하도록 구성했다. 4단계에서는 계층 별 쌍대비교 결과를 바탕으로 중요도에 따른 가중치를 부여하고 차등 점수를 적용하며, 이는 3단계에서 필수적으로 만족해야하는 지표들을 설정하고 평가하기 위해 사용된다. 3단계에서는 지표평가 후 "보통" 이상의 점수를 획득해야 2단계로 진행할 수 있고, 2단계에서는 3가지 큰 지표를 설정 후 총점 기준 60%이상의 최소득점 기준을 만족해야 1단계로 진행할 수 있도록 구성했다. 이러한 절차를 바탕으로 마지막 1단계에서는 100점을 만점으로 하는 6단계의 최종성능을 평가하는 결과를 제시할 수 있다. 본 연구에서는 국외 성능평가 사례 중 SWG와 관련된 지표를 구성하여 성능평가를 수행할 수 있는 기법을 제안하였다. 향후 지속적인 연구 진행 결과와 실측자료를 수집하여 수정 및 보완이 수행될 예정이다.

  • PDF

Study on the Utilization of Drinking Water Supply System of Air-water Heat Pumps Applicable to Laying Hen (산란계에 적용 가능한 공기-물 히트펌프의 음용수 공급시스템 이용기술에 관한 연구)

  • Paek, Yee;Kang, Suk-Won;Jang, Jae-Kyung;Kwon, Jin-Kyung
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.917-923
    • /
    • 2018
  • The drinking water supply system applicable to the laying hen consists of air-water heat pumps, drinking water tanks, heat stroage tank, circulation pumps, PE pipes, nipples, and control panels. When the heat pump system has power of 7.7 to 8.7 kW per hour, the performance coefficient is between 3.1 and 3.5. The supply temperature from the heat pump to the heat stroage tank was stabilized at about $12{\pm}1^{\circ}C$, but the return temperature showed a variation of from 8 to $14^{\circ}C$. Stratified temperature in the storage tank appeared at $12.^{\circ}C$, $13.5^{\circ}C$ and $14.4^{\circ}C$, respectively. The drinking water supply temperature remained set at $15^{\circ}C$ and $25^{\circ}C$, and the conventional tap water showed a variation for $23^{\circ}C$ to $30^{\circ}C$. As chickens grow older, the amount of food intake and drinking water increased. $y=-0.0563x^2+4.7383x+8.743$, $R^2=0.98$ and the feed intake showed $y=-0.1013x^2+8.5611x$. In the future, further studies will need to figure out the cooling effect on heat stress of livestock.

Development of a pipe burst detection model using large consumer's smart water meter and pressure data (대수용가 스마트미터와 수압 데이터를 이용한 소블록 내 관 파손사고 감지모델 개발)

  • Kyoung Pil Kim;Wan Sik Yu;Shin Uk Kang;Doo Yong Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.521-521
    • /
    • 2023
  • 지방상수도의 관 파손사고 감지 및 누수관리 방법에는 블록시스템 구축을 통한 소블록별 야간최소유량 감시방법이 가장 대표적이다. 야간최소유량은 새벽 2시와 4시 사이의 인구 활동 비율이 가장 낮은 새벽 시간대에 소블록에 공급된 유량을 의미하며, 대부분 유량 성분은 누수량일 것이라는 가정에서 출발한다. 그러나 아파트 중심의 주거 형태를 보이는 도심지의 경우, 새벽 시간대에도 다량의 물수요가 비정기적으로 발생하고 있어 관망의 이상 여부를 감시하기 위한 관리기준으로서 야간최소유량을 이용하기에는 높은 일간 변동성에 따른 한계가 있다고 할 수 있다. 즉, 야간최소유량은 관 파손사고 발생의 감시보다는 관로 연결 또는 급수전 분기 부위에서 발생하는 미량의 누수가 수개월에 걸쳐 누적되는 장기추세를 분석하여 누수탐사반의 투입 시점을 결정하기 위한 근거를 제시하기 위한 목적으로 사용되며, 아직까지 관 파손사고의 발생은 자체적인 감지보다는 민원에 의해 인지되는 경우가 많다. 최근, 스마트관망 구축사업(SWM) 등을 통해 관 파손 및 누수 감지를 위한 청음식 누수감지센서가 소블록 내 도입되고 있으나, 초기 시설투자에 큰 비용이 수반되며 주변 소음과 배터리 전원방식의 한계로 인하여 새벽 시간대에만 분석이 제한적으로 적용되는 경우가 많아 이 역시도 상시적인 관 파손사고의 감시기술이라 보기는 어렵다. 본 연구에서는 소블록 유입점에서의 유량·압력과 소블록 내에 설치된 대수용가 스마트미터, 그리고 사고감지를 위한 수압계 사이의 평상시 수리적 균형을 학습한 DNN(Deep Neural Network) 모델을 이용하여 관 파손사고를 실시간 감지하는 모델 개발연구를 수행하였다. 모델은 관 파손사고 감지를 위한 수압계의 최적 위치와 대수를 결정하기 위한 모듈과 관 파손사고 감지모듈로 구성되며, 1개 소블록 Test-Bed를 구축하여 모델을 생성하고 PDD 관망해석 모델을 통해 생성된 가상의 사고에 대한 감지 여부로서 개발 모델의 감지성능을 평가하였다.

  • PDF