• Title/Summary/Keyword: 무오차점

Search Result 47, Processing Time 0.023 seconds

A Study of Mechanism Synthesis of One-Degree-of-Freedom Planar Linkages with Revolute Joints (회전대우를 갖는 1자유도 평면기구의 기구합성에 관한 연구)

  • 조선휘;신동원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1330-1341
    • /
    • 1993
  • The kinematic synthesis deals with the systematic design of mechanisms for a given performance. The area of synthesis may be grouped into two categories to determine the type and to size the dimensions of a mechanism for a specified task. In this paper, using a database of mechanisms a designer can determine the type of mechanism conveniently and design equations are automatically generated for a given input performance. The solving method of design equations utilizes an optimization routine to obtain roots effectively. The linkages of 4, 6, and 8bars with revolute joints are considered in this study but may be extended to linkages of more bars.

Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery (정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구)

  • 윤형근;신교철;김영식
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.89-94
    • /
    • 1998
  • To make practical application of the MR image for stereotactic radiosurgery, the target point-achieved by acquisition of MR image in stereotactic radiosurgery planning system must agree with the actual isocenter of irradiation in real treatment. And the amount of distortion of the MR image must be known to make a correction for the agreement. A radish containing abundant water content was chosen as a homogeneous phantom for the purpose of verification of the agreement in this experiment. A dosimetric film was firmly attached to the small specially fabricated acryl plate and needle puncture was made through the film just into the acryl plate and a drop of oil was dropped into the hole of the film. The acryl plate with film was inserted into the radish and the dorp of oil represented the target point in MR image. After the image acquisition by stereotatic radiosurgery planning system, we achieved stereotactic coordinate of the target point represented by the oil drop. And we proceeded to actual irradiation to the target point according to the procedure of stereotactic radiosurgery. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the center of the radiation distribution and the target point represented by the hole in the film was measured. The discrepancy between two points was under 0.5 mm. so we could confirm good coincidence in homogeneous phantom such as radish. On the other hand, authors tried to use our home-made device for estimation of distortion of MR image.

  • PDF

Multi-Image RPCs Sensor Modeling of High-Resolution Satellite Images Without GCPs (고해상도 위성영상 무기준점 기반 다중영상 센서 모델링)

  • Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.533-540
    • /
    • 2021
  • High-resolution satellite images have high potential to acquire geospatial information over inaccessible areas such as Antarctica. Reference data are often required to increase the positional accuracy of the satellite data but the data are not available in many inland areas in Antarctica. Therefore this paper presents a multi-image RPCs (Rational Polynomial Coefficients) sensor modeling without any ground controls or reference data. Conjugate points between multi-images are extracted and used for the multi-image sensor modeling. The experiment was carried out for Kompsat-3A and showed that the significant accuracy increase was not observed but the approach has potential to suppress the maximum errors, especially the vertical errors.

A Study of Meshless Method Programming (무요소법 프로그래밍에 관한 연구)

  • 김학수;배동명
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.2
    • /
    • pp.110-118
    • /
    • 2002
  • The element free Galerkin method has been suggested by Belyschko, etc. it is applied for linear elastic analysis of solid problems and its convergence characteristics and stability are shown according to the weight function, influence domain and scattered points. The various numerical examples are performed to check the efficiency of 1D EFG and 2D EFG program by changing factors. As a result it have the best results when it used the cubic spline weight function and the scaling parameter d$_{max}$=2. These programs were developed by mixed language programming method using Visual Basic and the C language. so it is fast and efficient. and visually shown the result.t.

A Study on the Optimal Design of a R-S-S-R Three Dimensional Mechanism (3次元 R-S-S-R 機構의 最適設計 에 관한 硏究)

  • 김호룡;김경률
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.528-538
    • /
    • 1985
  • A R-S-S-R three dimensional mechanism is designed for crank-rocker type through the optimization technique. The nonlinear kinematic equation of the mechanism is formulated by adopting the concept of structural error and precision points. Taking this equation as an objective function, the required mechanism is optimally synthesized by the Fletcher-Davidon-Powell's method of optimization techniques. The structural errors due to the various positions of precision points are compared, and the results from the use of two penalty functions suggested respectively by Fiacco-McCormick and by Powell are also compared on their effectiveness. The mobility of the optimally designed mechanism is checked for the possibility of its motion, and when a mechanism is optimally designed, it is strongly suggested that the mobility must be checked on the designed mechanism.

Relative RPCs Bias-compensation for Satellite Stereo Images Processing (고해상도 입체 위성영상 처리를 위한 무기준점 기반 상호표정)

  • Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.4
    • /
    • pp.287-293
    • /
    • 2018
  • It is prerequisite to generate epipolar resampled images by reducing the y-parallax for accurate and efficient processing of satellite stereo images. Minimizing y-parallax requires the accurate sensor modeling that is carried out with ground control points. However, the approach is not feasible over inaccessible areas where control points cannot be easily acquired. For the case, a relative orientation can be utilized only with conjugate points, but its accuracy for satellite sensor should be studied because the sensor has different geometry compared to well-known frame type cameras. Therefore, we carried out the bias-compensation of RPCs (Rational Polynomial Coefficients) without any ground control points to study its precision and effects on the y-parallax in epipolar resampled images. The conjugate points were generated with stereo image matching with outlier removals. RPCs compensation was performed based on the affine and polynomial models. We analyzed the reprojection error of the compensated RPCs and the y-parallax in the resampled images. Experimental result showed one-pixel level of y-parallax for Kompsat-3 stereo data.

Establishment of Correspondent points and Sampling Period Needed to Estimate Object Motion Parameters (운동물체의 파라미터 추정에 필요한 대응점과 샘플링주기의 설정)

  • Jung, Nam-Chae;Moon, Yong-Sun;Park, Jong-An
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.26-35
    • /
    • 1997
  • This paper deals with establishing correspondent points of feature pints and sampling period when we estimate object motion parameters from image information of freely moving objects in space of gravity-free state. Replacing the inertial coordinate system with the camera coordinate system which is equipped within a space robot, it is investigated to be able to analyze a problem of correspond points from image information, and to obtain sequence of angular velocity $\omega$ which determine a motion of object by means of computer simulation. And if a sampling period ${\Delta}t$ is shortened, the relative errors of angular velocity are increased because the relative errors against moving distance of feature points are increased by quantization. In reverse, if a sampling period ${\Delta}t$ is lengthened too much, the relative error are likewise increased because a sampling period is long for angular velocity to be approximated, and we confirmed the precision that grows according to ascending of resolution.

  • PDF

A STUDY ON THE ERRORS UN THE CEPHALOMETRIC MEASUREMENTS (두부방사선사진의 계측오류에 관한 연구)

  • Na, Kwang-Cheon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.75-83
    • /
    • 1998
  • This study was done to recognize the importance of errors in measurements of cephalometric radiograph and to find the anatomical structures those need special care to select as a reference points through the detection of the systematic errors and estimation of random errors. For this purose, 100 cephalometric radiographs were prepared by usual manner and 61 reference points, and 130 measurement variables were established. Measurement errors were detected and estimated by the comparison of the 25 randomly-selected samples for repeated measurements with the main sample. The following results were obtained : 1. In comparison of the repeated measurements, there were statistical significant differences in 24 variables which were 18.4% of 130 total variables. 2. The frequency of the difference in identification of the reference points between the repeated measurements was very high in the root apex of upper incisor(as), the most posterior wall of maxilla(tu), soft tissue nasion(n'), soft tissue frontal eminence(ft), and ad3 in airway. 3. After correction of reference points marking until the level of below 5% significance, the range of random errors were from 0.67 to 1.71 degree or mm. 4. The variable shown the largest random error was the interincisal angle(ILs-ILi). 5. Measurement errors were mainly caused by the lack of precision in anatomic definitions and obscure radiographic image. From the above results, the author could find the high possibility of errors in cephalometric measurements and from this point, we should include error analysis in all the studies concerning measurments. In is essential to have a concept of error analysis not only for the investigator but also for a reader of other articles.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

3D Stereoscopic Terrain Extraction of Road Cut Failure Slope Using Unmanned Helicopter Photography System (무인 헬리콥터 사진촬영시스템을 이용한 도로 절개지 붕괴사면 3차원 입체 지형 추출)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • Acquisition of information on failure slope, which may cause apprehension of second hand damage, requires acquisition of fast and accurate topographical data and efficient expression in indirect surveying method without accessing as needed. Therefore, in this study, the images on the intended area were photographed through hovering in the air by approaching collapsed road cut slope with the use of unmanned helicopter photography system. As a result of comparing the points observed by no prism total station and the 10 coordinate points analyzed through image analysis, the averages of absolute values were shown to be 0.056m in X axis direction, 0.082m in Y axis direction and 0.066m Z axis direction. In addition, the RMSE of the error for 10 points of test points were 0.015636m in X axis direction, 0.021319m in Y axis direction and 0.018734m in Z axis direction. Therefore, this method can determine the range of slope and longitudinal and cross sections of each slope in dangerous area that cannot be approached in relational image matching method for the terrains of such collapsed cut slope.