• Title/Summary/Keyword: 무시멘트형

Search Result 6, Processing Time 0.017 seconds

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

The Distal Filling Effects on Hip Jont Function in Cementless Total Hip Replacement (인공 고관절 대치술에서 무시멘트형 스템의 원위부 압박이 고관철 성능에 미치는 영향)

  • 채수원;박상석;박재원
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2777-2785
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The intial stability has close relationship with the relative displacement of prosthessis and sponge bone at the proximal of femur. After implantation of the proshesis, the surrounding bone is partially shielded from load carrying and starts to resorb. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems. Three types of stems empolyed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

Biomechanical characteristics of the distal filling effects in cementless femoral stem (무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성)

  • Park, Sang-eok;Park, Jae-Won;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

Treatment of Recurrent Coxofemoral Joint Luxation by Total Hip Replacement in a Dog (대퇴관절 전치환술을 이용하여 개의 재발되는 대퇴관절 탈구증의 치료)

  • Kim, Jooho;Heo, Su-Young;Kim, Minsu;Lee, Kichang;Kim, Namsoo;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.125-128
    • /
    • 2014
  • A 7-year-old, intact female Golden Retriever weighing 38 kg was referred for left coxofemoral joint luxation. On physical examination, pain and crepitus were noted atthe left hip joint during joint extension. Radiological examination revealed coxofemoral joint luxation and mild degenerative bone changes in the left hip joint. We performed minimally invasive arthroscopy-assisted reduction with TightRope$^{(R)}$ as a treatment option; however, the left coxofemoral joint was reluxated after one month postoperatively. We performed cementless total hip replacement (THR) of the luxated left coxofemoral joint. At tenmonths after surgery, the dog could sit, stand, walk normally and jump comfortably without lameness. The thigh girth measurement of the operated limb was 108.6% of the contralateral limb. Based on the present case, THR can be a successful treatment for coxofemoral joint luxation in dogs with failed coxofemoral joint reduction.

A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM (무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구)

  • Kim, S.K.;Chae, S.W.;Choi, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF