References
- Biegler, F. B., Reuben, J. D., Harrigan, T. P., Hou, F. J. and Akin, J. E., 1995, 'Effect of Porous Coating and Loading Conditions on Total Hip Femoral Stem Stability,' J Arthroplasty, Vol. 10, No. 6
- 채수원, 정중환, 김성곤, 1998, '무시멘트형 인공고관절에서 직선형 및 곡선형 대퇴스템의 생역학적 특성,' 대한기계학회 논문집 A권, 제22권, 제5호
- Keyak, J. H., Rossi, S. A., Jones, K. A., and Skinner, H. B., 1998, 'Prediction of Femoral Fracture Load Using Automated Finite Element Modeling,' J. Biomechanics, Vol. 31, pp. 125-133 https://doi.org/10.1016/S0021-9290(97)00123-1
- Rohlman, A., Cheal, E. J., Hayes, W. C. and Bergmann, G., 1988, 'A Non Linear Finite Element Analysis of Interface Conditions in Porous Coated Hip Endoprostheses,' J. Biomechanics, Vol. 21, pp. 605-611 https://doi.org/10.1016/0021-9290(88)90224-2
- Van Rietbergen, B., Huiskes, R., Weinans, H., Sumner, D. R., Turner, T. M. and Galante, J. O., 1993, 'The Mechanism of Bone Remodeling And Resorption Around Press-Fitted THA Stems,' J Biomechanics, Vol. 26, No. 4, pp. 369-382 https://doi.org/10.1016/0021-9290(93)90001-U
- Huiskes, R., Weinans, H., Van Rietbergen, B., 1992, 'The Relationship Between Stress Shielding and Bone Resorption Around Total Hip Stems and the Effects of Flexible Materials,' Clin Orthop, Vol. 274, pp. 124-134
- Burke, D. W., O'Connor, D. O., Zalenski, E. B., Jasty, M. and Harris, W. H., 1991, 'Micromotion of Cemented and Uncemented Femoral Components,' J. Bone Joint Sur[Br], Vol. 73-B, No. 1, pp. 33-37
- Skinner, H. B., Kilgus, D. J., Keyak, J., Shimaoka, E. E., Kim, A. S. And Tipton, J. S., 1994, 'Correlation of Computed Finite Element Stresses to Bone Density After Remodeling Around Cementless Femoral Implants,' Clinical Orthopaedics And Related Research, No. 305, pp. 178-189
- Mann, K. A., Bartel, D. L., Wright, T. M. and Hurstein, A. H., 1995, 'Coulomb Frictional Interfaces in Modeling Cemented Total Hip Replacements : A More Realistic Model,' J. Biomechanics, Vol. 28, No. 9, pp. 1067-1078 https://doi.org/10.1016/0021-9290(94)00158-Z
- Rubin, P. J., Rakotomanana, R. L., Leyvraz, P. F., Zysset, P. K., Curnier, A. and Heegard, J. H., 1993, 'Friction Interface Micromotions and Anisotropic Stress Distribution in a Femoral Total Hip Component,' J. Biomechanics, Vol. 26 pp. 725-38
- Keaveny, T. M. and Bartel, D. L., 1992, ' Mechanical Consequence of Bone Ingrowth and Fibrous Tissue Encapsulation for a Cementless Hip Prothesis in the Long-Term,' Trans 38th ORS, Vol. 17, p. 73
- Harrigan, T. P. and Harris, W. H., 1991, 'A Three-Dimensional Non-Linear Finite Element Study of the Effect of Cement-Prosthesis Debonding Incemented Femoral Total Hip Components,' J. Biomechanics, Vol. 24, pp. 1047-1058 https://doi.org/10.1016/0021-9290(91)90021-E
- Davy, D. T., Kotzar, G. M., Brown, R. H., Heiple, K. G., Berilia, J. and Burstein, A. H., 1988, 'Telemetric Force Measurement Across the Hip After Total Arthroplasty,' J. Bone Joint Surg, Vol. 70-A, pp. 45-50
- Keaveny, T. M. and Bartel, D. L., 1993, 'Effects of Porous Coating and Collar Support on Early Load Transfer for a Cementless Hip Prosthesis,' J. Biomechanics, Vol. 26, pp. 1355-1368 https://doi.org/10.1016/0021-9290(93)90087-U