• Title/Summary/Keyword: 무부하 회로

Search Result 78, Processing Time 0.026 seconds

A Study of the WPT Module Using Inductive Coupling for the Convergence Applications (융합형 어플리케이션을 위한 자기유도 방식의 무선전력전송 모듈설계에 대한 연구)

  • Jeong, Byeong-Ho;Park, Ju-Hoon;Kang, Bo-An
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • Inductive Power Transfer (IPT) systems have successfully been developed and used to replace traditional conductive power transfer systems where physical connection is either inconvenient or impossible, such as biomedical implants, undersea vehicles, and contactless battery chargers of robots, for providing power to movable or detachable loads. Inductive Coupling uses magnetic fields to transfer power. There is a primary coil, which generates a magnetic field. Then there is another secondary coil which is composed of a capacitor and a coil, the capacitor creates a circuit with the primary and secondary coils. This paper discusses design method and several implementation alternatives for wireless energy transmission systems. It presents realization examples for these alternatives. Wireless energy transmission is investigated in numerous convergence applications due to its simplicity and advantages.

A Study on Steady State Characteristics of LLC Resonant Half Bridge Converter Considering Internal Losses (내부 손실이 고려된 LLC 공진형 하프브릿지 컨버터의 정상상태 특성에 관한 연구)

  • Ahn, Tae-Young
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.985-991
    • /
    • 2018
  • In this paper, an equivalent circuit reflecting the internal loss of the LLC resonant half bridge converter was proposed and a steady state characteristic equation including the loss factors was derived. Using the results, the frequency characteristics of I/O voltage gain and input impedance were compared with the lossless model In order to verify the proposed model and the derived equation, the main components of the 1kW class LLC resonant half bridge converter were selected under the same conditions and the steady state characteristics such as voltage gain and input impedance were compared. In particular, to compare more closely the steady state error of the two models, we observed the change in switching frequency with respect to the load current, which is considered to be the most important in the actual circuit design stage. As a result, it is confirmed that the error of the operating frequency is significantly improved from the proposed model and the analysis result.

High-Frequency Parameter Extraction of Insulating Transformer Using S-Parameter Measurement (S-파라메타를 이용한 절연 변압기의 고주파 파라메타 추출)

  • Kim, Sung-Jun;Ryu, Soo-Jung;Kim, Tae-Ho;Kim, Jong-Hyeon;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.259-268
    • /
    • 2014
  • In this paper, we suggest a method of extracting circuit parameters of the insulating transformer using S-parameter measurement, especially in high frequency range. At 60 Hz, conventionally, no load test and short circuit test are used to extract the circuit parameters. In this paper S-parameters measured from VNA(Vector Network Analyzer) were used to extract the transformer parameters using data fitting method (optimization). The S-parameters from the equivalent circuit using the extracted parameters showed good agreement with those from measurement. Furthermore, the transformer secondary voltages from the equivalent circuit model also coincide quite exactly to the measured secondary voltages in sinusoidal forms. Finally we assert that the proposed method to extract the parameters for the insulating transformer using S-parameter is valid especially in high frequency.

THE EFFECT OF REBONDING IN MICROLEAKAGE OF CLASS V RESTORATIONS UNDER LOAD CYCLING (부하순환 하에서 제V급 복합레진 수복물의 미세변연누출에 대한 재접착제의 효과에 관한 연구)

  • Youn, Yeon-Hee;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.527-533
    • /
    • 2004
  • One clinical technique recommended for improving marginal integrity is "rebonding" or application of unfilled resins to the surface of composite restoration. But continuously the restorations are affected with occlusal load. There is room for doubt that the rebonding agent has the positive effect on microleakage in spite of the stress generated by the occlusal load. This study determined the effect of rebonding on microleakage of Class V resin composite restorations under load cycling. Class V cavities were prepared on the buccal surface of 40 sound extracted premolars and restored with a hybrid light-cured resin composite according to manufacturers' directions. They were randomly divided into two groups consisting of 20 samples: a control(group I), without surface sealing, and the other group(group II) in which margins were etched and rebonded. After thermocycling, each of groups was divided into subgroups(group A, B), and load cycling(total 100,000 cycles with 4-100N load at a rate of 1 Hz) were applied on the group B. Assessment of microleakage utilized methylene blue dye penetration. The following results were obtained: 1. In the occlusal region, no significant difference was noted in the scores regardless of whether or not the rebonding agent was used(group TA-IIA, IB-IIB)(p>0.05). 2. In the cervical region, the control group with rebonding(group IIA) showed the better result than the group without rebonding(group IA)(p<0.05). 3. In the cervical region, the rebonded group with load cycling(group IIB) showed similar results to the group without rebonding(group IB) and no significant difference was noted(p>0.05).

  • PDF

Immediate Effect of Cigarette Smoking on Exercise (흡연이 운동에 미치는 단기 효과)

  • Choe, Kang-Hyeon;Choi, Cheol-Jun;Kim, Yong-Tae;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.511-516
    • /
    • 1992
  • Background: It is well known that cigarette smoking is the risk factor of lung cancer, chronic obstructive pulmonary disease and ischemic heart disease. But there are few reports about the immediate effect of cigarette smoking on the cardiopulmonary functions. The serum level of carbon monoxide increases during cigarette smoking. It is known that carbon monoxide increases respration rate, heart rate and cardiac output, with decrease in maximal oxygen consumption. So we have studied to determine the immediate effects of cigarette smoking on the cardiopulmonary function during exercise. Method: Thirteen healthy smoking male subjects were included in this study. Each subject was undertaken pulmonary function test and incremental exercise test on two separate days, one without smoking (control) and the other after smoking three cigarettes per hour for five hours. The order of the two tests was randomized. Results: 1) The mean age of the subjects was $25{\pm}4.9$ year-old and the mean smoking history was $6{\pm}5$ pack years. 2) The mean blood level of carbon monoxide on the smoking day was higher than that on the nonsmoking day ($5.97{\pm}1.34%$ vs. $1.45{\pm}0.83%$; p<0.01). 3) The mean maximal oxygen consumption on the smoking day was lower than that on the nonsmoking day ($2.09{\pm}0.32$ L/min vs. $2.39{\pm}0.32$ L/min; p<0.05). 4) The mean anaerobic threshold on the smoking day was lower than that on the nonsmoking day ($1.33{\pm}0.24$ L/min vs. $1.53{\pm}0.20$ L/min; p<0.05). 5) The mean heart rate at rest on the smoking day was higher than that on nonsmoking day ($84.38{\pm}11.06$ beats/min vs. $75.46{\pm}5.83$ beats/min; p<0.05). But the means of maximal heart rate on both days were not different. 6) The pulmonary function tests were similar on both days. Conclusion: There was no change in pulmonary function test, but the maximal oxygen consumption and anaerobic threshold were decreased on the smoking day. So it was concluded that cigarette smoking impaired the cardiovascular functions immediately during exercise.

  • PDF

Development of Embedded Controller for Autonomous Tractor Steering System (자율주행 트랙터의 조향 시스템을 위한 임베디드 제어기 개발)

  • Lee, Hyeon Seung;Kim, Ki Duck;Lee, Young Ju;Hwang, Dong Yeol;Shin, Beom Soo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.152-152
    • /
    • 2017
  • 본 연구에서는 비례제어밸브를 이용한 자율주행 트랙터 조향 시스템 제어를 위하여 저가의 임베디드 시스템을 사용한 제어기를 개발하였다. 차륜의 조향각 측정을 위하여 전륜 킹핀에 포텐시오미터를 설치하였으며, 비례제어밸브는 -10 ~ +10V의 전압으로 밸브 스풀의 위치제어를 수행하도록 하였다. 조향각 측정과 비례제어밸브의 위치제어를 위하여 각각에 AT90CAN128 AVR보드를 사용하였으며, CAN통신으로 조향각 데이터가 비례제어밸브 제어용 데이터로 전송될 수 있도록 하였다. 비례제어밸브 제어 보드에는 DAC기능을 추가하였으며 0 ~ 5V의 출력을 -10 ~ +10V의 전압으로 변환해 주는 인터페이스회로를 추가하였다. 일반적으로 GPS 등의 데이터 수신율이 20 Hz인 점을 감안하여 비례제어 밸브는 50 ms의 주기로 P-제어를 수행할 수 있도록 하였다. 향후 트랙터의 방향각을 설정하는 또 하나의 시스템으로부터 목표 조향각을 부여받는 것을 가상하여 별도의 MCU를 통해 목표 조향각을 송신한 후, 조향 유압실린더에 의한 전륜의 조향각 시간 응답 특성을 조사하였다. 실험은 트랙터의 전륜을 지면으로부터 들어올린 무 부하 상태에서 진행하였으며, 목표 조향각은 $7.5^{\circ}$, $15.0^{\circ}$, $22.5^{\circ}$ 등 3단계로 변경하며 시간응답 특성을 측정하였다. 최대 오버슈트 11%, 최소 오버슈트 8.6%, 정상상태 오차 약 $0.825^{\circ}$, 시정수(Time Constant)는 3단계의 목표 조향각 설정에서 각각 0.706초, 0.488초, 0.38초로 나타났다.

  • PDF

Characteristics of Non-Point Pollution Discharge of Urban Area According to Land Use (토지이용도에 따른 도시하천의 비점오염원 유출특성)

  • Park, Sung-Chun;Oh, Chang-Ryol;Kim, Jung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1229-1233
    • /
    • 2005
  • 본 연구는 도시지역의 강우-유출로 인한 비점오염물질의 유출특성 및 배출부하량을 조사하기 위하여 영산강권역의 풍영정천을 대상으로 조사하였다. 대상 유역의 토지이용별 구분은 논지역, 하류공단 및 논$\cdot$산지 복합 토지 이용특성, 공단 지역, 도시 분류식 지역, 소유역 출구지역으로 구분하였다. 시료의 채취는 강우시 4회에 걸쳐 조사하였으며, 매회 시료 채취 주기는 강우유출이 발생하기 전부터 시작하여 첨두유출량이 발생때까지 $1\~2$시간 간격으로 채취한 후 강우 종료 후 유출량 변화가 없을 때까지 $9\~12$단계로 세분하여 유출량과 pH, DO, BOD, COD, SS, T-N, T-P의 농도를 측정 하였다. 토지이용별 비점오염물질의 유량가중평균농도(EMC : Event Mean Concentration)를 살펴보면, BOD의 EMC는 $4.43\~14.22mg/{\ell}$의 분포를 보였으며, 도시 합류식 토지이용 특성을 지닌 P-4지점에서 가장 큰 농도를 보였을 뿐만 아니라 타 토지이용 특성에 비하여 두드러지게 초기 오염물질 유출 현상을 나타내었다. COD의 EMC는 $8.27\~18.81mg/{\ell}$의 분포를 보였으며, BOD 수질농도와 같이 P-4 지점에서 가장 큰 농도를 갖는 것으로 나타났다. SS의 EMC는 $35.76\~358.86mg/{\ell}$의 분포를 보였으며, 소유역의 중간지점이면서 논$\cdot$산지$\cdot$공단지역의 토지이용 특성을 지닌 P-2 지점에서 가장 큰 농도를 나타내었다. 이는 조사기간(Event 1, Event2) 동안 상류의 자연형하천 제방공사로 인한 토사유출로 인하여 다소 높게 나타난 것으로 판단된다. 또한, 대상유역 전반적으로 초기 오염물질 유출 현상을 보였으며, BOD와 COD 수질농도의 분포양상과는 다르게 강우량 및 강우강도에 많은 영향을 받는 것으로 나타났다. T-N의 EMC는 $1.61\~7.13mg/{\ell}$의 분포를 보였으며, T-P는 $0.03\~0.46mg/{\ell}$의 분포를 갖는 것으로 나타났다.

  • PDF

A Study on the High Frequency Resonant Inverter of Class D SEPP type using LS-ZVS-LSTC (LS-ZVS-LSTC를 이용한 D급 SEPP형 고주파 공진 인버터에 관한 연구)

  • Park, Dong-Han;Choi, Byeong-Joo;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.260-268
    • /
    • 2020
  • This paper presents the high frequency resonant inverter of class D SEPP(Single-Ended Push Pull) type using LS-ZVS-LSTC, which can reduce the switching losses during the turn-on and turn-off switching time. The analysis of high frequency resonant inverter using LS-ZVS-LSTC(Low-loss Turn-off Snubber Capacitor) proposed in this paper is described in general by adopting the normalized parameters. The operating characteristics of the proposed high frequency resonant inverter were also evaluated by using the control parameters such as the normalized control frequency(μ), the normalized load time constant(τ), the coupling factor(κ) and so on. Based on the characteristic values through the characteristics of evaluation, an example of the design method of the 1.8[kW] class D SEPP type high frequency inverter is suggested, and the validity of the theoretical analysis is verified using the experimental data.

Determination of Parameters of Equivalent Circuit Taking No-Load Losses Into Account for Single-Phase Induction Motors (단상 유도전동기의 무부하손실을 고려한 등가회로 정수의 결정)

  • Jwa, Chong-Keun;Kim, Do-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.358-363
    • /
    • 2010
  • This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.

Formulation of Calculation Method for Inducing Current by Aerial Power Distribution Line (가공 배전선에 의한 전자유도 발생 전류 계산 방법)

  • Lee, Sangmu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.30-36
    • /
    • 2015
  • The formulation of calculation method for electromagnetic inducing current by aerial power distribution line is established. Nearby telecommunication cables can be induced due to the leakage of neutral current because the neutral line of power distribution is grounded at every 50 m distance. By the existing calculation method, the neutral line is regarded as a shielding conductor and the neutral current roles as an inducing current. So the error range to real measurement value is largely extended because the changing effect of leakage current flowing in the ground is not reflected. The leakage current returns to the power substation through the ground and is cumulated as being closer to the substation. When this practical inducing mechanism is applied, the deviation rate of calculation can be drastically reduced within about 100 % range compared to 1000 % of the exsiting method.