• Title/Summary/Keyword: 무릎뼈

Search Result 43, Processing Time 0.028 seconds

Effect of inferomedial gliding of patella using non-eleastic taping on muscle activity of vastus medialis and vastus lateralis during sit to stand (앉은 자세에서 일어날 때 비탄력 테이핑을 이용한 무릎뼈의 아래 안쪽 활주가 안쪽넓은근과 가쪽넓은근의 근활성도에 미치는 영향)

  • Yun, Sang-Hyuk;Kang, Jong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.39-43
    • /
    • 2017
  • The purpose of this study was to investigate of effect of medial & inferior gliding of patella using non-elastic taping on muscle activation of vastus medialis & vastus lateralis during sit to st&ing. As a result of measure, it was confirmed that the muscle activity of vastus medialis is higher than total muscle activity when the inferomedial gilding compared to the medial gliding. The medial & downward gliding of patella more stable than medial direction. especially it will be effective on prevent or control of Patellofemoral pain syndrome. In this regard, the development of orthosis & sportswear for inferomedial gliding to patella will be efficiency to maintain healthy the knee joint.

Convergent Study of Personalized Modeling and 5-Axis Machining Technology Using Patellofemoral Bone DICOM Image (넙다리무릎뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 맞춤형 모델링과 5축 가공기술의 융합적 연구)

  • Yoon, Jae-Ho;Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.137-143
    • /
    • 2018
  • DICOM images of patellofemoral bones were converted into a stereolithography file, and a Unigraphics CAD program was used to create a CAD modeling in which there exists point, line and facet information. The modeling extraction of joint facets was performed by linking two adjacent points into lines in the stereolithography file by using the Unigraphics rapid spacing function and then linking the lines into facets to complete the entire modeling. This modeling extraction was performed based on the anatomical knowledge of joint facet directions. As a result, a personalized space modeling and solid modeling were produced for the joint facets of patellofemoral bones. This was followed by a CAM control computing operation of solid modeling on graphite materials and 5-axis machining of patellofemoral bones. That is the description of a method for a personalized implant modeling by using DICOM images of patellofemoral bones.

Comparison of Lower Extremity Muscle Activity depending on using Sit-to-Stand Assistive Device in Elderly People with Degenerative Arthritis (무릎 보조도구의 사용 유무에 따른 뼈관절염을 가진 노인의 하지 근육 활성도 비교)

  • Pyo, Seung-hyeon;Lee, Dong-geon;Hong, Soung-kyun;Jung, Sun-hye;Lee, Seung-hoo;Jeong, BeomHo;Lee, GyuChang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.359-360
    • /
    • 2018
  • 본 연구에서는 무릎 보조도구를 착용하지 않은 상태와 착용한 상태에서 앉았다 일어서기 동작 시의 무릎 근육의 활성도 차이를 비교하여, 착용형 무릎 보조도구가 무릎 뼈관절염을 가진 노인들의 하지 근육의 근 활성도에 미치는 영향을 알아보았다. 그 결과, 무릎 보조도구를 착용하지 않은 상태에 비해 보조도구를 착용한 상태에서 안쪽넓은근과 가쪽넓은근의 근 활성도가 통계적으로 유의하게 감소한 것으로 나타났다. 이를 통해, 무릎 보조도구가 앉았다 일어서기 동작 시 하지 근육을 보조하여 근 활성도를 감소시키는 등 무릎의 뼈관절염을 가진 노인들의 일상생활 보조에 유용할 수 있는 가능성을 확인할 수 있었다.

  • PDF

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

The Effect of Changes in Patellar Height Using Infra-Patellar Strap on the EMG Activity of Quadriceps Muscles During a Squat Exercise in Adults With Patellar Baja (하위 무릎뼈를 지닌 성인들을 대상으로 쪼그려 앉기 운동 시 하위 무릎뼈 스트랩을 이용한 무릎뼈 높이 변화가 넙다리네갈래근의 근 활성도에 미치는 영향)

  • Kang, Min-Hyeok;Kim, Ji-Won;Yoon, Ji-Yeon;Jang, Jun-Hyeok;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • The purpose of this study was to assess the influence of patellar height on quadriceps muscles' electromyography (EMG) activity during a squat exercise in adults with patella baja. For the study, we recruited 15 volunteers who had patella baja on the right side. We measured the EMG activity of the right rectus femoris, vastus medialis oblique, and vastus lateralis muscles during squat exercises under two conditions, specifically with and without an infra-patellar strap. The infra-patellar strap was applied below the tested patella to elevate the patella to a normal height. A paired t-test was used to compare the effects of patella height on EMG activity of the quadriceps muscles. The EMG activity of the rectus femoris (RF), vastus medialis oblique (VMO), and vastus lateralis (VL) muscles were significantly decreased during the squat exercise with the infra-patellar strap compared to the same exercise without the infra-patellar strap (p<.05), while the VMO/VL ratio was not different significantly between two conditions (p>.05). The findings of this study suggest that an infra-patellar strap may benefit people with patellar baja, as changes in patellar height could improve the efficiency of the quadriceps muscles.

Usefulness Evaluation of Merchant Auxiliary Equipment of Body Type Changing Suitable for X-ray Table Integral Type (체형변화에 적합한 X-선 검사대 일체형 Merchant 보조장비의 유용성 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2773-2779
    • /
    • 2013
  • The purpose of this study was to evaluate of the usefulness and to develop new auxiliary equipment that can bending angle of the bone of the knee various depending on the thickness of the thigh of the human. The subjects agreed for research purposes and were selected from normal person who do not have past knee-related diseases and grouped thin group A and thick group B for the thigh. We set in order to obtain images in the axial direction of the bones of the knee, $35^{\circ}$ to increase by $5^{\circ}$ angle of knee flexion, $45^{\circ}$, to $55^{\circ}$, and we performed combinations of 9 tests by incident angle X-ray per each angle, $40^{\circ}$, $50^{\circ}$ and $60^{\circ}$. As a result, we have developed an Merchant auxillary equipment of X-ray table integral type in radiographic images which was easy to use and could take images of various integral knee joint angles adjusting different body types. Using the auxiliary equipment, in the case of X-ray incident angle $50^{\circ}$ and $60^{\circ}$ with the knee flexion angle of $40^{\circ}$ in group A, and in group B, Knee flexion angle of $45^{\circ}$ and $35^{\circ}$, the X-ray incident angle at $60^{\circ}$, excellent images were derived. Future, it would be very useful in the examination of patients with a variety of body types.

노인과 건강: 욱신거리고 시큰거리는 무릎, 골이 텅텅 골다공증

  • Kim, Seon-Ju
    • The Monthly Diabetes
    • /
    • s.258
    • /
    • pp.72-73
    • /
    • 2011
  • 생활수준과 의료 질의 향상으로 평균 수명이 길어지면서 노인 인구가 증가함에 따라 골다공증의 발병률도 계속 증가하고 있다. 골다공증은 뼈의 구성성분인 칼슘이 서서히 소실되면서 구멍이 생겨 가벼운 외상에도 골절되는 상태로 뼈가 극도로 약해져 있는 경우를 말한다. 우리나라 여성의 42.6%가 골다공증 또는 골감소증이고 50대, 60대, 70대로 갈수록 골다공증 비율이 2배 이상 늘어난다고 한다. 골다공증은 예방 할 수 있는 질환이므로 지금부터라도 관심을 가지도록 하자.

  • PDF

Bone Segmentation Method based on Multi-Resolution using Iterative Segmentation and Registration (영역화와 정합 기법을 반복적으로 이용한 다중 해상도 기반의 뼈 영역화 기법)

  • Park, Sang Hyun;Lee, Soochahn;Yun, Il Dong;Lee, Sang Uk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.439-440
    • /
    • 2011
  • 최근 의료 장비들이 발전하고 진단 및 연구에 다양하게 이용되면서 이로부터 얻은 3차원 의료 영상들을 자동으로 처리해주는 기술의 수요가 늘고 있다. 자동 뼈 영역화 기법은 이러한 기술들 중 하나로써 골다공증이나 뼈 골절, 골격질환 등의 진단의 효율성을 크게 높여줄 것으로 기대되고 있다. 그러나 현재까지 이를 위한 다양한 연구들이 진행되었음에도 2차원 영상과는 달리 높은 데이터양과 주변 조직과의 모호한 경계들이 많다는 어려움 때문에 실제 진단에는 사용되지 못하고 있다. 이에 따라 본 논문에서는 다중 해상도를 기반으로 하여 영역화와 정합기법을 반복적으로 수행함으로써 3차원 의료 영상 내에서 자동으로 뼈를 영역화 해내는 기법을 제안한다. 낮은 해상도 단계에서 학습된 집합의 뼈 정보들을 이용하여 대략적인 뼈 위치를 검출하고, 이후 해상도를 높여가면서 정합 과정과 영역화 과정을 반복적으로 수행한다. 성능을 확인하기 위해 무릎 자기공명영상(magnetic resonance image)내에서 대퇴골(femur)과 경골(tibia)을 영역화 하는 실험을 진행하였으며 60개의 학습 데이터들을 바탕으로 40개 영상에서의 뼈들을 영역화 하였다.

  • PDF

Bone Segmentation Method based on Multi-Resolution using Iterative Segmentation and Registration in 3D Magnetic Resonance Image (3차원 무릎 자기공명영상 내에서 영역화와 정합 기법을 반복적으로 이용한 다중 해상도 기반의 뼈 영역화 기법)

  • Park, Sang-Hyun;Lee, Soo-Chan;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • Recently, medical equipments are developed and used for diagnosis or studies. In addition, demand of techniques which automatically deal with three dimensional medical images obtained from the medical equipments is growing. One of the techniques is automatic bone segmentation which is expected to enhance the diagnosis efficiency of osteoporosis, fracture, and other bone diseases. Although various researches have been proposed to solve it, they are unable to be used in practice since a size of the medical data is large and there are many low contrast boundaries with other tissues. In this paper, we present a fast and accurate automatic framework for bone segmentation based on multi-resolutions. On a low resolution step, a position of the bone is roughly detected using constrained branch and mincut which find the optimal template from the training set. Then, the segmentation and the registration are iteratively conducted on the multiple resolutions. To evaluate the performance of the proposed method, we make an experiment with femur and tibia from 50 test knee magnetic resonance images using 100 training set. The proposed method outperformed the constrained branch and mincut in aspect of segmentation accuracy and implementation time.