• Title/Summary/Keyword: 목표물 계수

Search Result 118, Processing Time 0.028 seconds

Suggestion of Load and Resistance Factored Design Value for PHC Bored Pile (PHC 매입말뚝의 하중저항 설계정수 제안)

  • Park, Jong-Bae;Park, Yong-Boo;Lee, Bum-Sik;Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.3 no.3
    • /
    • pp.279-286
    • /
    • 2012
  • The limit states design method is replacing the allowable stress design method worldwide, e.g. the design code of ISO and various construction codes of Korea are adopting the reliability based limit state method. This paper proposed LRFD design value which is one of limit states design method for the PHC bored pile used as building foundation. This paper analysed 81 load test results and the bearing design(Meyerhof method & SPT-CPT conversion method), and proposed LRFD value for each design reliability Index 2.33 and 3.0 for PHC bored pile. LRFD value of PHC bored pile represents 0.36~0.44 for Meyerhof method and 0.24~0.31 for SPT-CPT conversion method according to the deign reliability index.

Effects of the Organic Fatty Acid Salts on the Watertightness Properties of the Cementitious Materials (시멘트 재료의 수밀특성에 미치는 유기 지방산 염의 영향)

  • Na, Seung-Hyun;Kang, Hyun-Ju;Ahn, Kwang-Hoon;Song, Myong-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.529-532
    • /
    • 2008
  • The durability of concrete and the water-tightness properties of cementitous material are closely relation. So, water-tightness materials as natural minerals, organic fatty acid, organic fatty salts inorganic materials use for improvement of concrete durability. But these materials are somehow different in water-tightness mechanism. In this study, we studied on hydration properties and water-tightness properties of cementitous materials with zinc-stearate, a kind of organic fatty acid salts.

  • PDF

Reliability-based Design Criteria for Reinforced Concrete Structures Based on Partial and Combined Resistance Factor Formats (부분(部分) 및 조합저항계수형식(組合抵抗係數形式)에 의한 철근(鐵筋)콘크리트구조(構造)의 신뢰성(信賴性) 계기준(計基準))

  • Oh, Byung Hwan;Lee, Seong Lo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.87-97
    • /
    • 1990
  • There is the need to balance safety, economy and serviceability in all phases of society problems. This is especially true in structural code formulation. where a framework is established by which practicing structural engineers can be assured of designing structures that reasonably meet the above three objectives. The existing design codes, which are generally based on the structural theory and certain engineering experience, do not realistically consider the uncertainties of loads and resistances and the basic reliability concepts. The purpose of the present study is therefore to develop the realistic reliability-based design criteria to secure adequate safety arid reliability, and to derive the models for partial and combined resistance factor formats. To this end, the reliability levels of our existing design code for concrete structures are first evaluated and the target reliabilities are determined, the new code formats are evolved from these target reliabilities. The present study indicates that the proposed formats exhibit relatively-uniform reliability and reasonably take into account the different material characteristics of concrete and steel in concrete structures.

  • PDF

Evaluation of the Strength Required in Current Seismic Design Code (현행 내진설계 규준의 수평강도 요구에 대한 평가)

  • 한상환;오영훈;이리형
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-290
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, lateral strength required to maintain target ductility ratio was first calculated from nonlinear dynamic analysis of the single degree of freedom system. At the following step, base shear foeces specified in seismic design code compare with above results. If the base shear force required to maintain target ductility ratio was higher than the code specified one, the lack of required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of push-over analysis.

  • PDF

Generation of Artificial Time History Earthquake Record Family using the Least Squares Fitting Method (최소오차 최적합화 방법에 의한 인공 시간이력 지진기록군의 생성)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.31-38
    • /
    • 2008
  • Recently the necessity of time history analyses is increasing for the seismic analyses of a structure, and the seismic design provisions of IBC2003, ASCE and KBC2005 require the use of a minimum of seven earthquake records for the time history analyses. Earthquake records for the time history analyses could be selected from the database of the field-measured earthquake records having similar site conditions with the designed site, or from simulated sites satisfying the design spectrum. However, in this study seven earthquake records were generated using 50 earthquake records, classified as records measured at the rock, in the database of the Pacific Earthquake Research Center (PEER). Seven earthquake records were first selected by the least squares fitting method comparing the scaling factored response spectra with the specified design spectrum, and a family of seven artificial time history earthquake records was ultimately generated by multiplying scaling factors, which were calculated by the least squares fitting method and the SRSS averaging method, to the corresponding selected earthquake records.

Underwater Acoustic Communication Link Analysis (수중음향통신 링크 해석)

  • Choi, Young-Chol;Byun, Sung-Hoon;Lim, Yong-Kon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1465-1471
    • /
    • 2007
  • The electro-magnetic wave propagates through the air in the terrestrial communications, but the acoustic wave propagates through the seawater in the underwater acoustic communication(UAC). It makes the differences between the UAC link and the well hon air communication links. In this paper, we have studied path loss, absorption and ambient noise of the ocean as a medium for UAC. We have analyzed the absorption coefficient and ambient noise level of the coastal area of South Korea and suggested a strategy for the selection of the frequency band by considering the absorption coefficient and ambient noise level. Also, we present an illustrative example of a link budget for the QPSK UAC system which has carrier frequency 25kHz, bit rate 10kbps, range 1km and BER $10^{-3}$ in the shallow water environment with an ideal AWGN assumption.

Chloride Diffusion Coefficient at Reference Time for High Performance Concrete for Bridge Pylons in Marine Environment (해상교량 주탑용 고성능 콘크리트의 기준재령 염소이온 확산계수)

  • Yoon, Chul-Soo;Kim, Ki-Hyun;Yang, Woo-Yong;Cha, Soo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.435-444
    • /
    • 2012
  • High performance concrete mixes are selected and corresponding test specimens are made for the study of chloride diffusion coefficient at reference time. The concrete mixes were same designs as those used in construction of bridges located in a marine environment. Mix design variables included binder type, water-to-binder ratio, mineral admixtures to total binder weight substitution ratio, fine aggregate source, chemical water reducer admixture type for high strength and high flowability, and target slump or slump flow. The test results showed that the diffusion coefficients at reference time varied significantly according to the type of mineral admixtures and their substitution ratios. A model for diffusion coefficient at reference time considering the type of mineral admixture and the substitution ratio was developed. Diffusion coefficients from the developed model were compared with those from literature review, a previous model, and additional test results. All of the comparisons verified that the developed model can reasonably predict diffusion coefficients and the application of the model to the durability design against chloride penetration is appropriate.

Probabilistic Analysis of Repairing Cost Considering Random Variables of Durability Design Parameters for Chloride Attack (염해-내구성 설계 변수에 변동성에 따른 확률론적 보수비용 산정 분석)

  • Lee, Han-Seung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.32-39
    • /
    • 2018
  • Repairing timing and the extended service life with repairing are very important for cost estimation during operation. Conventionally used model for repair cost shows a step-shaped cost elevation without consideration of variability of extended service life due to repairing. In the work, RC(Reinforced Concrete) Column is considered for probabilistic evaluation of repairing number and cost. Two mix proportions are prepared and chloride behavior is evaluated with quantitative exterior conditions. The repairing frequency and cost are investigated with varying service life and the extended service life with repairing which were derived from the chloride behavior analysis. The effect of COV(Coefficient of Variation) on repairing frequency is small but the 1st repairing timing is shown to be major parameter. The probabilistic model for repairing cost is capable of reducing the number of repairing with changing the intended service life unlike deterministic model of repairing cost since it can provide continuous repair cost with time.

초전도 마그네틱 베어링의 부상력 특성에 관한 시뮬레이션

  • 유제환;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.122-128
    • /
    • 1997
  • 초전도체의 임계온도를 높이는 연구들이 수행되어 임계온도가 액체질소의 비등점(77K)보다 높은 산화물 고온 초전도체가 1986년에 발견되었고, 최근에는 $10^4A/cm^2$이상의 임계전류밀도를 갖는 덩어리형 고온 초전도체가 용융공정을 통해 개발되었으며, 산화물 고온 초전도체 $YBa_2 Cu_3 O_{7-y}$은 산소 조성이 7에 가까우며 임계온도가 95K로서 현재 가장 많이 사용되고 있다. 응용 분야로서는 수송분야, 의료분야, 전력분야, 그리고 기초과학분야등이 있고, 향후 상온 초전도체의 출현으로 인한 응용범위의 확대는 획기적일 것으로 예측되어 진다. 이중에 10$^{-8}$이하의 마찰계수를 갖는 초전도 마그네틱 베어링을 플라이휠 같은 에너지 저장장치에 적용시키는 연구가 국내외적으로 진행되고 있다. 여러 선진국에서는 용융공정된 초전도체를 이용하여 실험단계적인 플라이휠의 설계, 제작 및 성능실험을 진행중이거나 완성하였고, 제2단계 목표로서 실용화를 위한 대규모 플라이휠의 설계와 제작에 대한 연구가 진행중이다.

  • PDF

Development of Fire-resistant Concrete using Fibre Cocktail (섬유혼입공법을 적용한 고내화 콘크리트의 개발)

  • Youm, Kwang-Soo;Jeon, Hyun-Kyu;Won, Cheol;Kim, Heung-Youl
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.949-952
    • /
    • 2008
  • 화재안전 신뢰성이 확보된 고강도 콘크리트 구조물의 시장 공급을 위하여 GS건설에서는 2005년 부터 고강도 콘크리트 구조물의 강도 영역별 폭렬 저감 및 거동 안전성 평가와 수치해석 방법을 통한 경제적인 설계방법를 최종 연구목표로 하여 현재까지 콘크리트 재료의 열적 특성 확보와 구조부재 화재 특성 연구를 수행해 왔다. 강도발현, 시공성, 내화성능과 경제성에 대한 분석을 해외연구 기관에 의뢰하여 섬유혼입공법을 선정한 후 이에 대한 재료의 물리적 특성과 역학적 특성 실험결과를 바탕으로 고강도 콘크리트 구조부재의 내화성능을 예측 분석할 수 있도록 비열 모델, 열전도율모델, 압축강도 모델, 탄성계수 모델을 구축하였다. 또한 기둥과 보에 대한 내화실험을 실시하여 내화성능을 평가하였으며, 이에 대한 열적 해석을 병행하여 진행하였다.

  • PDF