• Title/Summary/Keyword: 모드 기여도

Search Result 2,849, Processing Time 0.032 seconds

Assessment of The Priority Order of Monitoring Devices on Maintenance for The Long-Term Safety of Existing Fill Dam (기존 필댐 장기간 안전관리를 위한 계측항목 유지보수 우선순위 산정)

  • Lee, Jongwook;Jeon, Jaesung;Lim, Heuidae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.67-79
    • /
    • 2009
  • Although readjustment of monitoring system for existing fill dam maintenance is needed by the sustainable increasing of the abandonment rate of monitoring devices by malfunction through the life-cycle of dam, monitoring plans for long-term dam safety has relied on the experience and the opinion of minor expert group without systematic and quantitative analysis on the failure modes and the priority order of monitoring devices on maintenance. In this study the priority order of monitoring devices of existing 5 fill dams was evaluated quantitatively based on the preceding study (Andersen et al, 1999) and the result recommended the establishment of real-time monitoring system for seepage, pore pressure and crest settlement as the readjustment plan for existing fill dam monitoring system. This readjustment plan matches well with the recommendation of PWRI (1984), JCOLD (1986) and the results from Bagherzadeh-Khakkahali and Mirghasemi (2005).

  • PDF

Free Vibration Analysis of Orthotropic Triangular Plates with Simplified Series Function (단순급수함수를 이용한 직교이방성 복합재료 삼각판의 자유진동해석)

  • 이영신;정대근;나문수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.849-863
    • /
    • 1992
  • A very simple and computationally efficient numerical method is developed for the free vibration of isotropic and orthotropic composite triangular plates. A set of two-dimensional simple series functions is used as an admissible displacement functions in the Rayleigh-Ritz method to obtain the natural frequencies, nodal patterns and mode shapes for the plates. From the prescribed starting function satisfying only the geometric boundary conditions, the higher terms in the series functions are constructed with adding order of polynominal. Natural frequencies, nodal patterns and mode shapes are obtained for right triangular plates with three different support conditions. The obtained numerical results are presented, and the isotropic and some orthotropic cases are verified with other numerical methods in the liternature.

Performance Improvement of WDM Channels using Inline Dispersion Management in Transmission Link with OPC Placed at Various Position (다양한 위치에 존재하는 OPC를 갖는 전송 링크에서 Inline 분산 제어를 이용한 WDM 채널의 성능 개선)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.668-676
    • /
    • 2010
  • Optimal net residual dispersions (NRDs) of inline dispersion management (DM) for compensating the signal distortion of $24{\times}40$ Gbps WDM channels in optical transmission links, in which optical phase conjugator (OPC) is placed from 250 km to 750 km by spacing 50 km in 1,000 km total transmission length of single mode fiber (SMF), are induced as a function of various ope positions. And, performance improvement of WDM channels in transmission links with the induced optimal NRD is investigated by comparing with that in transmission links with NRD = 0 ps/nm. It is confirmed that optimal NRDs are decided by displacement of OPC from mid-way of total transmission length, i.e. 500 km, and the determinating and applying of optimal NRD in case of ope displacement into transmitters is more stable and effective than that in case of ope displacement into receivers from 500 km. Also, it is shown that eye opening penalties (EOPs) of WDM channels in transmission links with optimal NRD are improved by 1.5 dB to 3 dB, which are related with OPC position, from that obtained in transmission links with fixed NRD of 0 ps/nm.

바이오센서 응용을 위한 그래핀 전극 표면의 결함준위에 따른 전기화학적 특성 분석

  • Park, Min-Jeong;Hwang, Suk-Hyeon;Im, Gi-Hong;Choe, Hyeon-Gwang;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.386.2-386.2
    • /
    • 2014
  • 본 연구에서는 바이오 센서 응용을 위해 그래핀을 전극으로 제작하여 그래핀 표면 결함준위에 따른 센서의 민감도를 전기화학 실험을 통해 관찰하였다. 그래핀은 니켈/구리촉매를 이용한 저 진공 화학 기상 증착 장비(Low-Pressure Chemical Vapor Deposition; LP-CVD)와 Photo-lithography로 제작한 것과 탄소 산화물을 환원시켜 만든 환원-그래핀, 두 가지를 사용하였다. 전기화학 실험에서 그래핀 전극 및 Silver/Silver chloride (Ag/AgCl), Fluorine doped Tin Oxide (FTO)은 작업 전극 및 기준 전극, 상대 전극으로 각각 사용하였고, 반응용액은 potassium hexacyanoferrate (III)를 농도를 다르게 하여 사용하였다. 그래핀의 표면 상태, 층수, 결함 정도 등 구조적인 특성은 원자력현미경(Atomic Force Microscopy; AFM), 주사 전자 현미경(Secondary Electron Microscopy; SEM)과 Raman spectroscopy를 각각 이용하여 확인하였고, 그래핀의 결함준위에 따른 반응면적 및 센서 감도 의존성을 전류모드-원자력현미경(Current-Atomic Force Microscopy; I-AFM)과 전기화학 임피던스 분광법(Electrochemical Impedance Spectroscopy; EIS)를 통해 그래핀 전극의 성능을 분석하고, 그래핀 결함 준위에 따른 센서 감도 의존성은 순환전위 분광법 (Cyclic Voltammetry; CV)를 이용하여 관찰하였다. 또한 농도가 다른 반응용액은 센서의 민감도를 관찰하는데 사용하였다. 결과적으로 LP-CVD로 성장한 그래핀과 환원-그래핀의 결함준위에 따른 센서의 성능을 비교 분석한 결과와 반응용액 농도에 따른 센서의 민감도 결과는 그래핀 바이오센서에 대한 응용 및 상용화를 앞당기는데 기여할 것으로 예상한다.

  • PDF

A Single-Phase Active Power Filter Control with Load Current Estimation Method (부하전류 추정기법에 의한 단상능동전력필터 제어)

  • 곽상신;이무영;최연호;임성운;권우현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.335-342
    • /
    • 2000
  • A new control method for a single-phase active power filter, based on a load current estimation using a DC capacitor voltage of active power filter without sensing nonlinear load current, is proposed in this paper. Because the method proposed can remove the load current sensor in comparison with a conventional method sensing the load current and DC capacitor voltage together, it can make the active power filter easy installation, low cost, small size with no performance detriment. In addition, sample-hold technique and proportional control method is adopted to control the DC capacitor voltage and as no delay element such as LPF or PI control in the conventional method is used, the transient response is fast and good. Operation of a single-phase active power filter which consist of eight mode is explained according to utility voltage, compensation current and switch state, and compensation characteristics of active power filter using proposed method is verified by experiment.

  • PDF

High Power Factor Dual Half Bridge Series Resonant Inverter for an Induction Heating Appliance with Multiple Loads (다부하를 갖는 유도가열기기를 위한 고역률 이중 하프브릿지 직렬공진 인버터)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.307-314
    • /
    • 1998
  • A novel high power factor Dual Half Bridge Series Resonant Inverter (DHB-SRI) for an induction heating appliance with multiple loads is proposed to remove the interferential acoustic noise caused by the difference between operating frequencies of adjacent loads. The circuit enables independent full power range control of two induction heating elements by one inverter circuit and has minimum switching losses due to the zero voltage switching characteristic. According to the mode analysis, I will explain the operation of the proposed circuit. To evaluate the required cooling capacity, loss analysis is performed through deriving some loss equations. In order to obtain the power factor correction capability and to lessen the system size, suitable design guides are given. Using the designed values, the proto-type circuit with 2.8kW power consumption for each induction heating element is built and tested to verify the operation of the proposed circuit.

  • PDF

Finite Element Analysis for the Safety Assessment of Take-out Robot (취출로봇의 안전성 평가를 위한 유한요소해석)

  • Hong, Hee-Rok;Lee, Joon-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1241-1246
    • /
    • 2014
  • Take-out robots used for handling of the plastic parts manufactured with the injection mold are usually the gantry type that consists of long and thin links. In this study, we want to evaluate the safety of the take-out Robot structure through finite element analysis. The take-out Robot is automated robot to transport from one location to another in the molded article. The take-out Robot structure has a 380 kilogram weight, a 1300mm width, a 670.5mm depth and a 670mm height. It confirms the equivalent stress and the deformation of the load and its own weight through weight analysis. It looks for the natural frequency of the take-out robot through modal analysis. It confirms the acceleration, the normal stress and the deformation about the natural frequency of the take-out robot through response analysis. Also It repeats the analysis by changing the structure of the take-out robot, to confirm the results and it is determined whether the safety of the structure. These analysis results are effectively used to reduce the vibration of the take-out robot.

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

Effects of Structural Parameter Variations on Dynamic Responses (해석(解析)모델의 구조변수(構造變數) 변동(變動)이 동적응답에 미치는 영향(影響))

  • Park, Hyung Ghee;Lim, Boo Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.59-67
    • /
    • 1993
  • The variations of the natural frequencies and the peak response acceleration at the top of prestressed concrete reactor building due to random variability and/or model uncertainty of structural parameters are studied. The results may be used as essential input parameters in seismic probabilistic risk assessment or seismic margin assessment of the reactor building. The sensitivity test of each structural parameter is first performed to determine the most influential parameter upon the natural frequency of structure model. Then Monte Carlo simulation technique is applied to evaluate the effect of parameter variation on the natural frequencies and the peak response acceleration. The acceleration time history is obtained by direct integration scheme. As the study results, it is found that the fundamental natural frequency and the peak response acceleration at the top of the building are most strongly affected by Young's modulus among the structural parameters, in which the value of mean plus one standard deviation obtained by probabilistic approach deviates up to about (+)12% from the result of deterministic method. Considering the uncertainty of flexural rigidity, the structural responses vary in range of (-)4%~(+)14%.

  • PDF

The Study on Effect of Exhaust Gas Characteristics according to Aromatic compound Content in Diesel (경유의 방향족 함량 변화가 배출가스에 미치는 영향 연구)

  • Kim, Shin;Min, Kyong-Il;Yim, Eui-Soon;Ha, Jong-Han;Na, Byung-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.549-561
    • /
    • 2014
  • According to reports in EU and USA, Aromatic ingredient in diesel estimated the causative agent of air pollution. Because reduction of total aromatic and Poly-aromatic compound content are decreasing environmentally harmful emissions HC, NOx, PM. It is necessary to investigate correlationship between automotive technology and fuel quality in Korea. This study examines emission effect of two representative domestic vehicles(2.2 L for emission of Euro 4, 5) and five kinds of domestic diesel fuel (total aromatic compound content 26, 28, 30 wt% and poly-aromatic compound content 3, 5 wt%). Finally, Environmental impact assessment was studied between vehicle and diesel fuel.