• Title/Summary/Keyword: 면조명

Search Result 308, Processing Time 0.027 seconds

A Study on the Development of LED Spot Luminaire for Image Lighting (영상조명용 144[W] LED 스폿 등기구 개발에 관한연구)

  • Lee, Jang-Weon;Im, Jee-Weon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.271-276
    • /
    • 2010
  • This study manufactured spot lighting fixtures for the broadcasting stage and LED lighting fixtures, measured the illumination, dimming, and color temperature, and installed LED lighting and spot Fresnel lighting to the camera by turns with the same subject to confirm and look into the possibility of replacement of LED lighting fixtures by shooting the figures and comparing them. The analysis of the photographed subject found that the lighting apparatus of LED 144[W] was superior to the tungsten halogen illuminator of 1 [kW] in terms of brightness and color of an image. The measuring of the energy used in 144 [W] LED lighting equipment and tungsten halogen 1[kW] lighting equipment suggested that LED saved more than 80 [%] of energy in the same intensity of illumination. The comparison of the light distribution and light intensity distribution of halogen tungsten illuminator of 1[kW] and LED 144[W] lighting apparatus found that when a subject received concentrated lighting, effective lighting is possible because the illumination intensity on the surface of the lighted subject was high. In performance halls or studios of about 6 [m] height, there is no problem of illumination intensity in LED 144 [W] illuminator. Therefore, it is possible to replace the existing tungsten halogen 1 [KW] illuminator one to one.

자판기 천적 관계를 조명한다

  • 한국자동판매기공업협회
    • Vending industry
    • /
    • v.2 no.7 s.8
    • /
    • pp.73-78
    • /
    • 2003
  • 자연계의 모든 생물은 대체로 천적이 있다. 생물은 언제나 많은 천적으로 둘러싸여 있으며 이로 인해 자연의 평형이 이루어지고 있다. 그런데 이런 천적관계는 비단 생물에 있어서만 적용되는 게 아니다. 자판기 분야도 그 외부환경 요인이라든가 경쟁 대상 품목 등에 있어 천적의 관계를 형성하고 있는 경우가 많다. 필수 불가결한 품목특성을 갖지 못하는 자판기 특성상 유난히 이러한 천적의 연결고리를 많이 찾아 볼 수 있다. 금호 기획취재에는 자판기의 천적 관계를 조명해 보는 시간을 마련했다. 이 천적관계도 산업의 발전을 막는 나쁜 면으로서 만이 아닌 싫든 좋든 공존 공생해야 하는 동반자적 관계이다. 이러한 측면에서 천적관계 조명을 통해 보다 자판기 산업의 자생력을 강화할 수 있는 계기를 만들고자 함이 본란의 기획취지이다.

  • PDF

Accuracy evaluation of llluminance Calcuation methods Compared with the Monte-Carlo Simulation (몬테카를로 시뮬레이션을 위한 기준으로 한 조도 계산법의 정확도 평가)

  • 김창섭;심상만
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.45-53
    • /
    • 1996
  • 평균조도 계산법 중에서 국내에서 주로 사용되는 3배광법과 ZCM의 정확도를 비교하고, 그 적용한계를 파악하였다. 비교방법은 전반확산형 조명기구와 직접식 조명기구에 대하여 3배광법과 ZCM에 의한 조명률을 계산하고, 이 값들을 이용하여 여러 상황하에서의 평균조도를 계산하였다. 몬테카를로 시뮬레이션으로 동일상황에서의 조도값을 구하고, 이 값과 3배광법과 ZCM의 조도값을 각각 비교하였다. MCS법의 정확도는 Moon위 해석적인 방법과 비교하여 입증하였다. 연구결과는 다음과 같다. 1. 방의 크기에 따른 평균조도 비교에서 전반확 형 조명기구와 직접식 조명기구의 경우 3배광법 보다 ZCM이 평균조도 오차가 적었다. 2. 광원의 수 변화에 따른 평균조도 비교에서 직접식 조명기구의 경우 3배광법은 광원의 수가 증가할수록 평균조도 오차가 감소하다가 다시 증가하였고 ZCM 은 점차적으로 감소하였다. 3. 실내면 반사율 변화에 따른 비교에서 직접식 조명기구의 경우 오차 범의가 3배광법에서 크고 ZCM에서 적게 나타냈다. 4. 방의 형태 변화에 따른 평균조도 비교에서 직접식 조명기구의 경우 방의 폭이 좁고 길이가 긴 공간에서 3배광법과 ZCM모두 오차가 크게 낱났다. 또 정방형에서 가까울수록 오차는 작아지면서 3배광법 보다 ZCM의 오차가 적었다. 그러므로 우리나라에서 혼용되고 있는 3배광법과 ZCM중에서 정확도가 높은 ZCM선택이 바람직하다.

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.

Optical System Design of Freeform Lens Lighting as a Replacement for Gobo Lighting (고보 조명을 대체할 수 있는 Freeform Lens 조명 광학계 설계)

  • Byeong-Mun Yang;Min-Gyu Kim;Mee-Suk Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.276-282
    • /
    • 2023
  • In this paper, we designed a lighting optical system using a freeform lens as a substitute for expensive gobo lighting. Unlike gobo lighting, freeform lens lighting does not use an image mask, and it can form and project an image directly on the lens surface using only a single lens, thus reducing the cost compared to gobo lighting. In order to verify the performance of freeform lens lighting with these advantages, we conducted an illuminance simulation. As a result, it was confirmed that it can replace gobo lighting because it has an illuminance distribution similar to the image we want to irradiate and a light efficiency of 47% similar to the performance of gobo lighting.

Development of Web-based Light Facility Control Management System (Web기반 조명시설 제어 관리 시스템의 개발)

  • Chang, Byong-Kun;Jeon, Chang-Dae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.182-189
    • /
    • 2005
  • In this paper, A web-based server system was developed based on PDA(Personal Digital Assistants) for controlling and managing light facilities on-line with wireless communication efficiently. The control box of current light facilities may be implemented based on simple operational function. The operational quality of the light facilities will be efficiently improved with some practical advantages such as reduction of required facility, manpower and time in managing the lights and control boxes by using the popular PDA.

Development the Program Calculating Illuminance and Luminace for Road Lighting (도로 조명에 의한 조도 및 휘도 분포 계산 프로그램 개발)

  • Kim, Gi-Hoon;Sim, Sang-Man;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.49-54
    • /
    • 1998
  • 본 연구에서는 도로 조명 설비에 있어서의 도로 면의 휘도 분포 및 조도 분포뿐만 아니라, 평균 휘도 및 평균 조도, 전반 균제도와 길이상의 균제도, 임계 증분, 광막휘도, 글레어 등의 계산을 수행하는 프로그램(Lighting Analysing Program for Road, LAPRoad)을 개발하였다. 도로 및 조명기구의 기하학적 배치와 함께 노면의 반사 특성과 조명기구의 배광 특성이 사용자의 선택에 의해 입력된다. 계산의 정확도와 LAPRoad의 유용성을 검증하기 위해 실제 조도와 휘도를 측정하고 이를 계산 결과의 비교하여 좋은 결과를 얻었다.

  • PDF

Daylight color temperature to match 60W LED lighting system development for the interior general Lighting (주광의 색온도와 일치하는 실내 전반 조명용 60W LED 조명제품 개발)

  • Kim, Jin-Hong;Lim, Su-Keun;Park, Joung-Wook;Kim, Gi-Hoon;Song, Sang-Bin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.197-200
    • /
    • 2009
  • 주광의 색온도와 일치하는 실내 전반 조명용 60W급 LED 조명제품 개발하기 위하여 실내 주광에 적합한 LED를 선정하고, 색온도, 광색제어를 위한 구동회로 및 제어회로를 설계 제작 하였다. 그리고 1W급 Cool White, Warm White Package LED 총 168 EA를 적용하여 주광의 색온도와 일치하는 실내전반 조명용 LED 조명 System 을 개발하였다. 주광의 색온도와 일치하는 실내 전반용 LED 조명제품은 60W급 LED SMPS 구동회로 및 광색/색온도 제어회로 설계, 면발광을 위한 방열 설계 및 기구 구조 설계를 통하여 개발되었으며, 직접 시제품을 제작하고 그 성능을 측정하였다. 그 결과 회로 효율은 85% 이상, 색온도는 $3,000{\sim}7,000K$에서 실시간으로 제어 가능 하고, 원하는 색온도을 구현 할 수 있도록 하였으며, 발산각 또한 최대 광도의 1/2 기준으로 $100^{\circ}$ 이상을 만족시켰다.

  • PDF

An Analysis of the Current Status on the Interior Lighting Design of Dining Tables in Apartment (공동주택 식탁공간의 조명 현황 분석)

  • Jeong, Keun-Young;Hong, Seong-Kwan;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.1-9
    • /
    • 2008
  • Light is a critical element for people to live and do creative activities in residential buildings. Especially, light in the dim)ing room is the most important factor for psychological and emotional effects but people are living under the poor light environment. Most people even are not well aware of good lighting environment. Also, the domestic lighting designers just follow the Korean Standards illuminance but it isn't appropriated for our cultural and social sides. This study investigated illuminance and color temperature of dining tables, and also analyzed the results of those in actual residential buildings.